CCC-M

Description
CCC series terminals are the ideal choice for connecting 35 mm2 CAT copper/stainless steel cables. 907/697. The special terminal entry of the lugs allows crimping of the cable insulation inside, providing protection against oxidation and avoiding the use of heat shrink sleeves. The terminal flap ensures maximum stability even under violent stress. The absence of the inspection hole helps prevent the infiltration of moisture and dirt. The size of the collar of the terminals is such that crimping of the connectors can be performed without compromising their strength capacity.
Read all Close

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Classification and data ordering
Minimum operating temperature
-50   °C
Maximum operating temperature
150   °C
Number of holes on the palm
1
Easy insertion input
Yes
Surface treatment
tin plating
Conductor body material
Electrolitic copper with purity above 99.95%
Annealing
Yes
Customs code
85369010

drwr-dim
CCC-M
Technical information Weight and dimensions Logistic
tipo Screw pitch Range of cable cross section [mm²] ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A (conductor) [mm] A (insulation) [mm] A [mm] Ø (conductor) [mm] Ø (insulation) [mm] Cable stripping length [mm] Ø1 [mm] Unit in minimal packaging [pce] Unit in standard packaging [pce]
CCC35-M10/1 M10 35 10.5 25 11 13 64 75 31 10 41 10 12.5 31 16 25 75
CCC35-M12/1 M12 35 13.2 25 14 16 67 81 31 10 41 10 12.5 31 16 25 75
CCC150-M12/1 M12 150 13.2 36.5 14 18 92 106 32 20 17 22 35 27 5 25
CCC95-M12 M12 95 13.2 35 15 18 84 99 10 38 48 15 19.5 42 24 15 30
CCC35-M10/1
Screw pitch M10
Range of cable cross section [mm²] 35
ØD [mm] 10.5
B [mm] 25
N [mm] 11
M [mm] 13
I [mm] 64
L [mm] 75
A (conductor) [mm] 31
A (insulation) [mm] 10
A [mm] 41
Ø (conductor) [mm] 10
Ø (insulation) [mm] 12.5
Cable stripping length [mm] 31
Ø1 [mm] 16
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 75
CCC35-M12/1
Screw pitch M12
Range of cable cross section [mm²] 35
ØD [mm] 13.2
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 67
L [mm] 81
A (conductor) [mm] 31
A (insulation) [mm] 10
A [mm] 41
Ø (conductor) [mm] 10
Ø (insulation) [mm] 12.5
Cable stripping length [mm] 31
Ø1 [mm] 16
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 75
CCC150-M12/1
Screw pitch M12
Range of cable cross section [mm²] 150
ØD [mm] 13.2
B [mm] 36.5
N [mm] 14
M [mm] 18
I [mm] 92
L [mm] 106
A (conductor) [mm] 32
A (insulation) [mm] 20
A [mm] –
Ø (conductor) [mm] 17
Ø (insulation) [mm] 22
Cable stripping length [mm] 35
Ø1 [mm] 27
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 25
CCC95-M12
Screw pitch M12
Range of cable cross section [mm²] 95
ØD [mm] 13.2
B [mm] 35
N [mm] 15
M [mm] 18
I [mm] 84
L [mm] 99
A (conductor) [mm] 10
A (insulation) [mm] 38
A [mm] 48
Ø (conductor) [mm] 15
Ø (insulation) [mm] 19.5
Cable stripping length [mm] 42
Ø1 [mm] 24
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data