F-M RING TERMINAL

RING TERMINAL, PRE-INSULATED WITH PVC, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
These terminals are particularly recommended for use with fl exible conductors. They are manufactured from electrolytic copper tube with a purity greater than 99.9% and with dimension so as to ensure both a good electrical connection and an adequate resistance to vibrations and traction; they are annealed and tin plated. For the same cable section are available different types of connectors with PA6.6 sleeve entry of different diameters so as to accept conductors with various insulation thickness. The insulated sleeve additionally will accept the conductor so avoiding a sudden bending of the conductor itself at the connector entry, highly increasing its resistance to the mechanical solicitations that could break the conductor strands. The operating temperature range is – 20 to + 115°C (Surge + 130°C).
Read all Close

Features
  • Technical information
  • Material composition and treatments
  • Weight and dimensions
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
75   °C
Threshold of operating temperature for short periods
90   °C
Bend angle of the connection
0   °
Number of holes on the palm
1
Type of insulation
partial
Easy insertion input
Yes
Self-extinguishing fire class according to UL 94
V0
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Insulated cover material
Polyvinylchloride PVC
Annealing
Yes
Centre distance between holes
0   mm
Type of packaging
bag; box
Unit in minimal packaging
100   PCE
Electrocode
3681
ETIM Class 7
Solderless copper terminals for copper conductors [EC001052]
Customs code
85369010
ROHS compliant
Yes

RF-M
Insulated cover colour Red RAL 3000
Range of cable cross section 0.25 ÷ 1.5 mm²
Weight and dimensions Logistic
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Unit in standard packaging [pce]
RF-M2 M2 2.2 5.6 2.8 4.5 8.7 17.3 4.2 10.1 4 5.5 1.8 4.6 0,616 3,000
RF-M3 M3 3.2 5.6 2.8 4.5 8.7 17.3 4.2 10.1 4 5.5 1.8 4.6 0,580 3,000
RF-M3.5 M3.5 3.7 5.6 2.8 4.5 8.7 17.3 4.2 10.1 4 5.5 1.8 4.6 0,580 3,000
RF-M3.5/1 M3.5 3.7 6.2 3.1 7.1 11.3 20.2 4.2 10.1 4 5.5 1.8 4.6 0,638 3,000
RF-M4 M4 4.3 7 3.5 6.5 10.7 20 4.2 10.1 4 5.5 1.8 4.6 0,660 3,000
RF-M4/3 M4 4.3 7.8 3.9 7.1 11.3 21 4.2 10.1 4 5.5 1.8 4.6 0,720 3,000
RF-M5 M5 5.3 7.8 3.9 7.1 11.3 21 4.2 10.1 4 5.5 1.8 4.6 0,674 2,500
RF-M6 M6 6.4 9.4 4.7 8.1 12.3 22.8 4.2 10.1 4 5.5 1.8 4.6 0,780 2,500
RF-M6/1 M6 6.4 12 6 10.3 14.5 26.3 4.2 10.1 4 5.5 1.8 4.6 1,160 2,000
RF-M7 M7 7.2 9.4 4.7 8.1 12.3 22.8 4.2 10.1 4 5.5 1.8 4.6 0,720 2,500
RF-M8 M8 8.4 12 6 10.3 14.5 26.3 4.2 10.1 4 5.5 1.8 4.6 1,020 2,000
RF-M10 M10 10.5 15.5 7.75 13.05 17.25 30.8 4.2 10.1 4 5.5 1.8 4.6 1,340 1,500
RF-M12 M12 13 18 9 15.5 19.7 34.5 4.2 10.1 4 5.5 1.8 4.6 1,533 1,500
BF-M
Insulated cover colour Blue RAL 5015
Range of cable cross section 1.5 ÷ 2.5 mm²
Weight and dimensions Logistic
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Unit in standard packaging [pce]
BF-M2 M2 2.2 5.6 2.8 5 9.2 17.8 4.2 10.1 4.9 6.4 2.4 4.6 0,712 3,000
BF-M3 M3 3.2 5.6 2.8 5 9.2 17.8 4.2 10.1 4.9 6.4 2.4 4.6 0,698 2,500
BF-M3.5 M3.5 3.7 5.6 2.8 5 9.2 17.8 4.2 10.1 4.9 6.4 2.4 4.6 0,681 2,500
BF-M3.5/1 M3.5 3.7 6.2 3.1 6.5 10.7 19.6 4.2 10.1 4.9 6.4 2.4 4.6 0,783 2,500
BF-M4 M4 4.3 8 4 6.5 10.7 20.5 4.2 10.1 4.9 6.4 2.4 4.6 0,832 2,500
BF-M5 M5 5.3 8 4 7.5 11.7 21.5 4.2 10.1 4.9 6.4 2.4 4.6 0,813 2,000
BF-M6 M6 6.4 9.4 4.7 8.6 12.8 23.3 4.2 10.1 4.9 6.4 2.4 4.6 0,906 2,000
BF-M6/1 M6 6.4 12 6 10.3 14.5 26.3 4.2 10.1 4.9 6.4 2.4 4.6 1,274 2,000
BF-M6/2 M6 6.4 8.4 4.2 5.4 9.6 19.6 4.2 10.1 4.9 6.4 2.4 4.6 0,695 2,500
BF-M7 M7 7.2 10 5 7.8 12 22.8 4.2 10.1 4.9 6.4 2.4 4.6 0,940 2,000
BF-M8 M8 8.4 12 6 10.3 14.5 26.3 4.2 10.1 4.9 6.4 2.4 4.6 1,060 1,500
BF-M10 M10 10.5 15.5 7.75 13.05 17.25 30.8 4.2 10.1 4.9 6.4 2.4 4.6 1,429 1,500
BF-M12 M12 13 18 9 15.5 19.7 34.5 4.2 10.1 4.9 6.4 2.4 4.6 1,680 1,000
GF-M
Insulated cover colour Yellow RAL 1021
Range of cable cross section 4 ÷ 6 mm²
Weight and dimensions Logistic
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Unit in standard packaging [pce]
GF-M3 M3 3.2 8 4 8.1 14.5 26.2 6.4 14.1 6.6 8.1 3.6 7 1,840 1,000
GF-M3.5 M3.5 3.7 8 4 8.1 14.5 26.2 6.4 14.1 6.6 8.1 3.6 7 1,860 1,000
GF-M4 M4 4.3 9 4.5 8.1 14.5 26.7 6.4 14.1 6.6 8.1 3.6 7 1,860 1,000
GF-M5 M5 5.3 9 4.5 8.1 14.5 26.7 6.4 14.1 6.6 8.1 3.6 7 1,820 1,000
GF-M6 M6 6.4 11 5.5 11.1 17.5 30.7 6.4 14.1 6.6 8.1 3.6 7 2,140 1,000
GF-M6/1 M6 6.4 11 5.5 8.1 14.5 27.7 6.4 14.1 6.6 8.1 3.6 7 1,820 1,000
GF-M7 M7 7.2 11 5.5 11.1 17.5 30.7 6.4 14.1 6.6 8.1 3.6 7 2,040 1,000
GF-M8 M8 8.4 13.6 6.8 12.1 18.5 33 6.4 14.1 6.6 8.1 3.6 7 2,372 800
GF-M8/1 M8 8.4 11 5.5 8.1 14.5 27.8 6.4 14.1 6.6 8.1 3.6 7 1,707 1,000
GF-M10 M10 10.5 13.6 6.8 12.1 18.5 33 6.4 14.1 6.6 8.1 3.6 7 2,000 800
GF-M10/1 M10 10.5 15.5 7.75 13.85 20.25 35.7 6.4 14.1 6.6 8.1 3.6 7 2,500 800
GF-M12 M12 13 19 9.5 15.1 21.5 38.7 6.4 14.1 6.6 8.1 3.6 7 3,180 500
GF-M14 M14 15 21 10.5 16.1 22.5 40.7 6.4 14.1 6.6 8.1 3.6 7 3,172 500
GF-M16 M16 17 24 12.5 17.1 23.5 43.2 6.4 14.1 6.6 8.1 3.6 7 3,600 500

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data