A-2M RING TERMINAL

RING TERMINAL, TWO-HOLE CONNECTION, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
A-2M series lugs angled 315° and 345° are manufactured from electrolytic copper tube with a purity greater than 99.9%. The dimensions of the tube are designed to obtain the most effi cient electrical conductivity and mechanical strength to resist vibration and pull out. The double hole fi xing ensures greater mechanical stability even in the presence of electrodynamic stresses. CEMBRE lugs are annealed to guarantee optimum ductility, an absolute necessity for connectors which will have to withstand the severe deformation arising when compressed and any bending of the palm during installation. In applications subject to vibration, terminals still have to perform a reliable connection, annealing plays a vital role in avoiding cracking or breaks between the barrel and palm. The presence of an inspection hole facilitates full insertion of the conductor, whilst the barrel length has been designed to allow easy and accurate positioning of the dies during the crimping operation. Lugs are electrolytically tinplated to avoid oxidation.
Read all Close

Features
  • Technical information
  • Material composition and treatments
Minimum operating temperature
-50   °C
Maximum operating temperature
150   °C
Bend angle of the connection
0   °
Number of holes on the palm
2
Easy insertion input
Yes
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Annealing
Yes

A2-2M
Range of cable cross section 10 mm²
Technical information Weight and dimensions Logistic Classification and data ordering
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code
A2-2M4-12 Yes M4 4.3 10 4 5 30.5 12 34.5 9 4.6 10 6.8 5,461 100 100 3684 Tube cable lug for copper conductors [EC001051] 85369010
A2-2M8-20 Yes M8 8.4 15 11 11 44.5 20 55.5 9 4.6 10 6.8 8,329 ; box 100 100 3684 Tube cable lug for copper conductors [EC001051] 85369010
A3-2M
Range of cable cross section 16 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A3-2M8-20 Yes M8 8.4 15 11 11 52.5 20 63.5 11.5 5.8 13 7.9 11,060 ; box 100 100 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A3-2M12-40 Yes M12 13.2 20 12 14 72 40 84 11.5 5.8 13 7.9 25,142 ; box 50 50 Tube cable lug for copper conductors [EC001051] 85369010
A5-2M
Range of cable cross section 25 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A5-2M8-20 Yes M8 8.4 15 11 9 48 20 59 13 7 15 9.3 13,495 ; box 100 100 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A5-2M8-24-24 Yes M8 8.4 15 11 24 67 24 78 13 7 15 9.3 18,690 ; box 100 100 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A5-2M10-24-13 Yes M10 10.5 18 11 13 56 24 67 13 7 15 9.3 14,850 ; box 100 100 3684 85369010 Yes
A7-2M
Range of cable cross section 35 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A7-2M12-25 Yes M12 13.2 21 14 16 62.5 25 76.5 15.5 8.9 17 11.7 85369010
A7-2M12-40 Yes M12 13.2 21 14 16 77.5 40 91.5 15.5 8.9 17 11.7 30,800 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A7-2M12 Yes M12 13.2 21 14 16 82 44.5 96 15.5 8.9 17 11.7 32,915 ; box 100 100 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A7-2M10-25 Yes M10 10.5 19 11 12 58.5 25 69.5 15.5 8.9 17 11.7 24,600 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010
A7-2M10 Yes M10 10.5 19 10 11 77 44.5 87 15.5 8.9 17 11.7 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M
Range of cable cross section 50 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A10-2M6 Yes M6 6.4 19 11 8 78 44.5 89 16.5 10 19 13 41,880 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M8-22 Yes M8 8.4 19 11 11 58.5 22 69.5 16.5 10 19 13 30,876 ; box 50 50 85369010 Yes
A10-2M8-20 Yes M8 8.4 19 11 11 56.5 20 67.5 16.5 10 19 13 29,800 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M8-24-24 Yes M8 8.4 19 11 24 73.5 24 84.5 16.5 10 19 13 38,240 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M8-30 Yes M8 8.4 19 11 11 66.5 30 77.5 16.5 10 19 13 34,900 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M12-25 Yes M12 13.2 21 14 16 66.5 25 80.5 16.5 10 19 13 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M12 Yes M12 13.2 21 14 16 86 44.5 100 16.5 10 19 13 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M10-24-13 Yes M10 10.5 19 11 13 62.5 24 73.5 16.5 10 19 13 31,633 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M8 Yes M8 8.4 19 11 11 81 44.5 92 16 10 18 13 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A10-2M10 Yes M10 10.5 20 11 13 83 44.5 94 16 10 18 13 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A14-2M
Range of cable cross section 70 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A14-2M8-24-24 Yes M8 8.4 21 11 24 53 24 88 18.5 11.3 21 14.6 49,800 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A14-2M8 Yes M8 8.4 21 11 11 84.5 44.5 95.5 18 11.3 20 14.6 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A14-2M10-24 Yes M10 10.5 21 11 13 66 24 77 18 11.3 20 14.6 40,880 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A14-2M12-25 Yes M12 13.2 22 14 16 70 25 84 18 11.3 20 14.6 43,280 ; box 50 50 3684 85369010
A14-2M12-30-29 Yes M12 13.2 22 14 29 88 29 102 18 11.3 20 14.6 53,440 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010
A14-2M12-40 Yes M12 13.2 22 14 16 85 40 99 18 11.3 20 14.6 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010
A14-2M12 Yes M12 13.2 22 14 16 89.5 44.5 103.5 18 11.3 20 14.6 54,220 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A14-2M14 Yes M14 15 25 16 18 91.5 44.5 107.5 18 11.3 20 14.6 54,220 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A14-2M10 Yes M10 10.5 21 11 13 86.5 44.5 97.5 18 11.3 20 14.6 ; box 50 50 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M
Range of cable cross section 95 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A19-2M6 Yes M6 6.4 25 11 10 90 44.5 101 22.5 13.5 25 17.5 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M10-24-13 Yes M10 10.5 25 11 13 72.5 24 83.5 22.5 13.5 25 17.5 66,720 ; box 25 25 3684 85369010 Yes
A19-2M10-24-26 Yes M10 10.5 25 11 26 85.5 24 96.5 22.5 13.5 25 17.5 78,560 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M10-40 Yes M10 10.5 25 11 13 88.5 40 99.5 22.5 13.5 25 17.5 80,980 ; box 25 25 3684 85369010
A19-2M10 Yes M10 10.5 25 11 13 93 44.5 104 22.5 13.5 25 17.5 82,533 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M12-25 Yes M12 13.2 25 14 29 76.5 25 90.5 22.5 13.5 25 17.5 85369010
A19-2M12-30-29 Yes M12 13.2 25 14 29 94 30 108.5 22.5 13.5 25 17.5 84,160 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M12 Yes M12 13.2 25 14 16 96 44.5 110 22.5 13.5 25 17.5 85,640 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M14-25 Yes M14 15 25 16 18 78.5 25 94.5 22.5 13.5 25 17.5 85369010
A19-2M16 Yes M16 17 25 17 19 99 44.5 116 22.5 13.5 24.7 17.5 85,640 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A19-2M14 Yes M14 15 25 16 18 98 44.5 114 22.5 13.5 25 17.5 ; box 25 25 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M
Range of cable cross section 120 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A24-2M8-20 Yes M8 8.4 28.5 11 11 68 20 79 24 15.2 27 19.6 85369010
A24-2M8-24-29 Yes M8 8.4 28.5 11 29 90 24 101 24 15.2 27 19.6 103,440 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M10 Yes M10 10.5 28.5 11 13 94.5 44.5 105.5 24 15.2 27 19.6 104,480 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M10-22 Yes M10 10.5 28.5 11 13 72 22 83 24 15.2 27 19.6 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010
A24-2M10-25/24 Yes M10 10.5 24 11 13 50 25 86 24 15.2 27 19.6 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M10-33.5 Yes M10 10.5 28.5 11 13 83.5 33.5 94.5 24 15.2 27 19.6 92,960 ; box 25 25 85369010
A24-2M12-30-29 Yes M12 13.2 28.5 14 29 96 30 110 24 15.2 27 19.6 106,680 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M12-40 Yes M12 13.2 28.5 14 16 93 40 107 24 15.2 27 19.6 104,616 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M12 Yes M12 13.2 28.5 14 16 97.5 44.5 111.5 24 15.2 27 19.6 106,360 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M14 Yes M14 15 28.5 16 18 99.5 44.5 115.5 24 15.2 27 19.6 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A24-2M16 Yes M16 17 28.5 17 19 100.5 44.5 117.5 24 15.2 27 19.6 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M
Range of cable cross section 150 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A30-2M8-20 Yes M8 8.4 31.5 11 13 78 20 89 26.5 16.7 30 21.5 ; box 25 25 85369010
A30-2M10-24-28 Yes M10 10.5 31.5 11 28 97 24 108 26.5 16.7 30 21.5 130,860 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M10 Yes M10 10.5 31.5 11 13 102.5 44.5 113.5 26.5 16.7 30 21.5 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M12-30 Yes M12 13.2 31.5 14 16 91 30 105 26.5 16.7 30 21.5 122,920 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M12-30-29 Yes M12 13.2 31.5 14 29 104 30 118 26.5 16.7 30 21.5 141,000 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M12-40 Yes M12 13.2 31.5 14 16 101 40 115 26.5 16.7 30 21.5 136,380 ; box 15 15 3684 85369010 Yes
A30-2M12 Yes M12 13.2 31.5 14 16 105.5 44.5 119.5 26.5 16.7 30 21.5 124,980 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M14 Yes M14 15 31.5 16 18 107.5 44.5 123.5 26.5 16.7 30 21.5 146,540 ; box 25 25 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A30-2M14-33.5 Yes M14 15 31.5 16 18 96.5 33.5 112.5 26.5 16.7 30 21.5 144,548 ; box 25 25 85369010
A37-2M
Range of cable cross section 185 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A37-2M10-25 Yes M10 10.5 35.5 11 13 90 25 101 29 19.2 32 24.4 158,907 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A37-2M10 Yes M10 10.5 35.5 11 13 109.5 44.5 120.5 29 19.2 32 24.4 182,000 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A37-2M12 Yes M12 13.2 35.5 14 16 112.5 44.5 126.5 29 19.2 32 24.4 190,693 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A37-2M12-32 Yes M12 13.2 35.5 14 16 100 32 114 29 19.2 32 24.4 166,893 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A37-2M12-30-31 Yes M12 13.2 35.5 14 31 113 30 127 29 19.2 32 24.4 190,200 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A37-2M14-35 Yes M14 15 35.5 16 18 105 35 121 29 19.2 32 24.4 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010
A37-2M14 Yes M14 15 35.5 16 18 114.5 44.5 130.5 29 19.2 32 24.4 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A37-2M16-40 Yes M16 17 35.5 17 19 111 40 128 29 19.2 32 24.4 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010
A37-2M16 Yes M16 17 35.5 17 19 115.5 44.5 132.5 31.5 19.2 34.6 24.4 ; box 15 15 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A48-2M
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] Range of cable cross section [mm²] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A48-2M10-20 Yes M10 10.5 39 11 13 91 20 240 102 33 21.1 37 27.2 ; box 15 15 3684 85369010
A48-2M10-35 Yes M10 10.5 39 11 13 106 35 240 117 33 21.1 37 27.2 ; box 15 15 85369010
A48-2M10 Yes M10 10.5 39 11 13 115.5 44.5 240 126.5 33 21.1 37 27.2 258,967 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A48-2M12-30-31 Yes M12 13.2 39 14 31 119 30 133 33 21.1 37 27.2 258,000 ; box 10 10 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A48-2M12-35 Yes M12 13.2 39 14 16 109 35 240 123 33 21.1 37 27.2 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010
A48-2M12-40 Yes M12 13.2 39 14 16 114 40 240 128 33 21.1 37 27.2 246,400 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A48-2M12 Yes M12 13.2 39 14 16 118.5 44.5 240 132.5 33 21.1 37 27.2 254,520 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A48-2M14-40 Yes M14 15 39 16 18 116 40 240 132 33 21.1 37 27.2 85369010
A48-2M14 Yes M14 15 39 16 18 120.5 44.5 240 136.5 33 21.1 37 27.2 272,333 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A48-2M16 Yes M16 17 39 17 19 121.5 44.5 240 138.5 33 21.1 36.3 27.2 226,933 ; box 15 15 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M
Range of cable cross section 300 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A60-2M10 Yes M10 10.5 44 11 13 122.5 44.5 133.5 40 23.7 44 30.6 371,100 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M12 Yes M12 13.2 44 14 20 129.5 44.5 143.5 40 23.7 44 30.6 376,840 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M12-40 Yes M12 13.2 44 14 20 125 40 139 40 23.7 44 30.6 341,600 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M12-30-38 Yes M12 13.2 44 14 38 133 30 147 40 23.7 44 30.6 365,760 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M14 Yes M14 15 44 16 22 131.5 44.5 147.5 40 23.7 44 30.6 365,580 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M16-40 Yes M16 17 44 17 22 127 40 144 40 23.7 44 30.6 ; box 5 5 85369010
A60-2M16 Yes M16 17 44 17 22 131.5 44.5 148.5 40 23.7 44 30.6 355,720 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A60-2M16-35 Yes M16 17 44 17 22 122 35 139 40 23.7 44 30.6 329,600 ; box 5 5 85369010
A60-2M16/36 Yes M16 17 36 17 19 84 44.5 145.5 42 23.7 47 30.6 ; box 5 5 Tube cable lug for copper conductors [EC001051] Yes
A80-2M
Range of cable cross section 400 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A80-2M14-40 Yes M14 15 51 16 22 134 40 150 42 27 47 35 ; box 5 5 85369010
A80-2M14 Yes M14 15 51 16 22 138.5 44.5 154.5 42 27 47 35 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A80-2M16-40 Yes M16 17 51 19 22 134 40 153 42 27 47 35 498,853 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010
A80B-2M16-40 No M16 17 51 19 22 134 40 153 42 27 47 35 85369010
A80-2M16 Yes M16 17 51 19 22 138.5 44.5 157.5 42 27 47 35 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A80-2M16-50 Yes M16 17 51 19 22 144 50 163 42 27 47 35 85369010
A80-2M16/41 Yes M16 17 41 19 19 91 44.5 152.5 44 27 48.4 35 ; box 5 5 Tube cable lug for copper conductors [EC001051] Yes
A100-2M
Range of cable cross section 500 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A100-2M16 Yes M16 17 56.5 19 19 139.5 44.5 158.5 43.5 30.3 48 39.5 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A100-2M12 Yes M12 13.2 56.5 14 20 137.5 44.5 152 46 30.3 51 39.5 ; box 1 1 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A120-2M
Range of cable cross section 630 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Spy hole Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] Centre distance between holes [mm] L [mm] A [mm] Ø [mm] Cable stripping length [mm] Ø1 [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 Customs code ROHS compliant
A120-2M12 Yes M12 13.2 61.6 14 22 109 44.5 167.5 58 33.4 64 42.6 806,000 ; box 5 5 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes
A120-2M16 Yes M16 17 61.6 19 22 109 44.5 172.5 58 33.4 64 42.6 804,300 ; box 1 1 3684 Tube cable lug for copper conductors [EC001051] 85369010 Yes

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm