Lang en
  • en
  • en_US
  • it
  • fr
  • de
  • es
  • zh_CN
Country Spain
  • Italy
  • Usa / Canada / Mexico
  • France
  • Germany
  • UK / Ireland
  • Other countries
  • Spain
Lang en
  • en
  • en_US
  • it
  • fr
  • de
  • es
  • zh_CN
Country Spain
  • Italy
  • Usa / Canada / Mexico
  • France
  • Germany
  • UK / Ireland
  • Other countries
  • Spain

ANE-U FORK TERMINAL

FORK TERMINAL, PRE-INSULATED WITH PA 6.6, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
ANE-U series terminals are made from electrolytic Copper with a purity greater than 99.9%, rolled, Tin plated and brazed. The interior of the PA6.6 insulated sleeve is funnel shaped so as to ensure complete and easy introduction of the conductor strands. The operating temperature range is – 20 to + 115°C (Surge + 130°C). In order to achieve the best electrical and mechanical performance it is suggested that they are crimped using dies and tools specifi cally developed for this purpose by CEMBRE.
Read all Close

Features
  • Technical information
  • Material composition and treatments
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
115   °C
Threshold of operating temperature for short periods
130   °C
Fork type
flat
Reference standard
UL 486A-486B
Typology
single
Insulated cover colour
Black RAL 9005
Type of insulation
partial
Easy insertion input
Yes
Self-extinguishing fire class according to UL 94
V2
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Insulated cover material
Polyamide PA6.6
Annealing
Yes
Internal surface of the barrel
knurled
Dielectric strength of the insulated cover
16.5   kV/mm
Type of packaging
; box
Unit in minimal packaging
100   PCE
Unit in standard packaging
100   PCE
Electrocode
3684
ETIM Class 7
Solderless copper terminals for copper conductors [EC001052]
Customs code
85369010
ROHS compliant
Yes

ANE-U
Weight and dimensions
tipo Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] Range of cable cross section [mm²] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
ANE2-U4 M4 9.8 7.5 16.5 4.3 7 10 35.1 9 21 8 9.5 4.8 12 2,940
ANE2-U5 M5 11.5 7.5 16.5 5.3 7 10 35.1 9 21 8 9.5 4.8 12 3,220
ANE3-U4 M4 10 10 20 4.3 8 16 41.1 10 24 9.2 10.5 5.9 13 4,000
ANE3-U5 M5 11.5 10 20 5.3 8 16 41.1 10 24 9.2 10.5 5.9 13 4,140

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data