PL-M
THROUGH CONNECTOR, PRE-INSULATED WITH PVC, FOR COPPER CONDUCTORS
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Features
Technical information
Minimum operating temperature   
-20°C
Maximum operating temperature   
80°C
Threshold of operating temperature for short periods   
90°C
Type of connector   
butt through connector
Central stop   
Yes
Type of insulation   
full
Surface treatment   
tin plating
Crimping geometry   
radial
Material composition and treatments
Conductor body material   
Rame elettrolitico con purezza superiore al 99,95%
Insulated cover material   
Polyvinylchloride PVC
Annealing   
Yes
Weight and dimensions
Cable stripping length   
9mm
Logistic
Unit in minimal packaging   
100PCE
Classification and data ordering
Customs code   
85369010
Certifications
ROHS compliant   
Yes
PL-M
tipo Insulated cover colour Range of cable cross section [mm²] Ø [mm] Ø2 [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Unit in standard packaging [pce] Self-extinguishing fire class according to UL 94 UL standard
PL01-M green 0.2 - 0.5 2.15 1.15 25 15 25 3 3.8 3000
PL03-M red 0.25 - 1.5 3.3 1.8 25 15 25 4 4.7 1000 V0 486C
PL06-M blue 1.5 - 2.5 4 2.42 25 15 25 5 6.9 1500 V0 486C
PL1-M yellow 4 - 6 5.25 3.6 32 16 32 6.5 7 500 V0 486C
Via Serenissima, 9 - 25135 Brescia - ITALY