Lang en_US
  • en
  • en_US
  • it
  • fr
  • de
  • es
  • zh_CN
Country France
  • Italy
  • Usa / Canada / Mexico
  • France
  • Germany
  • UK / Ireland
  • Other countries
  • Spain
Lang en_US
  • en
  • en_US
  • it
  • fr
  • de
  • es
  • zh_CN
Country France
  • Italy
  • Usa / Canada / Mexico
  • France
  • Germany
  • UK / Ireland
  • Other countries
  • Spain

C-CST SLEEVE CONNECTOR

SLEEVE CONNECTOR, TIN-PLATED, FOR COPPER CONDUCTORS
Certifications & approvals
  • USDA
    USDA

Features
  • Technical information
  • Material composition and treatments
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-50   °C
Maximum operating temperature
150   °C
Barrel type
open
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Annealing
Yes
Internal surface of the barrel
smooth
Type of packaging
; box
Electrocode
0610
ETIM Class 7
C-clamp for round wire [EC002290]
Customs code
85369010
ROHS compliant
Yes

C-CST
Technical information Weight and dimensions Logistic
tipo Type of branch circuit Cross section range of the through cable [mm²] Cross section range of the branch cable [mm²] C [mm] L [mm] B [mm] Gross weight [g] Unit in minimal packaging [pce] Unit in standard packaging [pce]
C6-C6ST tap connection; joint connection 2.5 ÷ 6 1.5 ÷ 6 9 9.8 6.4 2,646 100 100
C10-C10ST tap connection; joint connection 10 1.5 ÷ 10 12 12.6 8.4 5,770 100 100
C16-C16ST tap connection; joint connection 16 1.5 ÷ 16 17 19.4 12 19,786 100 100
C25-C10ST tap connection; joint connection 16 ÷ 25 1.5 ÷ 10 17 19.8 13 22,600 50 50
C25-C25ST tap connection; joint connection 25 16 ÷ 25 17 21.4 13 21,800 50 50
C35-C16ST tap connection; joint connection; joining two running conductors 35 ÷ 40 1.5 ÷ 16 21 24.6 15.4 40,000 25 25
C35-C35ST tap connection; joint connection; joining two running conductors 21 26.6 15.6 38,240 25 25
C70-C25N-ST tap connection; joint connection 63 ÷ 70 1.5 ÷ 25 21 26.4 17.5 38,764 50 50
C50-C25ST tap connection; joint connection 25 ÷ 25 4 ÷ 25 25 32.9 21 91,720 25 25
C50-C50ST tap connection; joint connection 50 35 ÷ 50 26 33 21 88,360 25 25
C70-C35ST tap connection; joint connection 50 ÷ 70 4 ÷ 40 28 33 21 98,280 25 25
C70-C70ST tap connection; joint connection; joining two running conductors 50 ÷ 70 35 ÷ 70 28 34 21 89,408 25 25
C95-C35ST tap connection; joint connection 35 ÷ 35 4 ÷ 40 29 40.6 26 149,440 25 25
C95-C70ST tap connection; joint connection; joining two running conductors 95 ÷ 100 40 ÷ 70 29 41 26 146,080 25 25
C95-C95ST tap connection; joint connection 95 ÷ 100 63 ÷ 100 29 41 26 142,880 25 25
C120-C120ST tap connection; joint connection 110 ÷ 125 25 ÷ 125 30 45 28 167,240 15 15
C150-C120ST tap connection; joint connection; joining two running conductors 31 45 28 155,947 15 15
C150-C150ST tap connection; joint connection; joining two running conductors 30 45 28 122,560 25 25
C185-C95ST tap connection; joint connection; joining two running conductors 185 16 ÷ 100 31 45 28 129,280 15 15
C185-C185ST tap connection; joint connection 120 ÷ 185 120 ÷ 185 22.6 68 34 230,667 15 15
C240-C120ST tap connection; joint connection 150 ÷ 240 95 ÷ 120 22.6 68 34 237,733 15 15

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data