P-U FORK TERMINAL

FORK TERMINAL, PRE-INSULATED WITH POLYCARBONATE, FOR COPPER CONDUCTORS, HALOGEN FREE
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)

Features
  • Technical information
  • Material composition and treatments
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
115   °C
Threshold of operating temperature for short periods
130   °C
Fork type
Flat
Typology
single
Type of insulation
partial
Easy insertion input
Yes
Self-extinguishing fire class according to UL 94
V0
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Insulated cover material
Polycarbonate PC10500AC
Annealing
Yes
Internal surface of the barrel
knurled
Halogen free
Yes
Type of packaging
; box
Unit in minimal packaging
100   PCE
Unit in standard packaging
100   PCE
Electrocode
3681
ETIM Class 7
Solderless copper terminals for copper conductors [EC001052]
Customs code
85369010
ROHS compliant
Yes

VP-U
Insulated cover color Green
Range of cable cross section 0.2 ÷ 0.5 mm²
Weight and dimensions
tipo Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
VP-U3 M3 5.5 5.5 9.7 3.2 4 18.7 4.2 10 3 4.4 1.2 4.6 0,340
VP-U3.5 M3.5 6 6.5 10.7 3.7 3.8 19.5 4.2 10 3 4.4 1.2 4.6 0,350
VP-U4 M4 6.5 7.5 11.7 4.3 3.7 20.4 4.2 10 3 4.4 1.2 4.6 0,376
RP-U
Insulated cover color Red
Range of cable cross section 0.25 ÷ 1.5 mm²
Weight and dimensions
tipo Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
RP-U3 M3 5.5 5.5 9.7 3.2 4 19.6 4.2 10.1 4 5.5 1.8 4.6 0,580
RP-U3.5 M3.5 6 6.5 10.7 3.7 3.8 20.4 4.2 10.1 4 5.5 1.8 4.6 0,600
RP-U3.5/2 M3.5 6.4 6.5 10.7 3.7 3.8 20.4 4.2 10.1 4 5.5 1.8 4.6 0,663
RP-U4 M4 6.5 7.5 11.7 4.3 3.7 21.3 4.2 10.1 4 5.5 1.8 4.6 0,620
RP-U4/1 M4 8.5 7.5 11.7 4.3 3.7 21.3 4.2 10.1 4 5.5 1.8 4.6 0,760
RP-U4/2 M4 7.5 7.5 11.7 4.3 3.7 21.3 4.2 10.1 4 5.5 1.8 4.6 0,725
RP-U5 M5 8.5 7.5 11.7 5.3 3.7 21.3 4.2 10.1 4 5.5 1.8 4.6 0,720
RP-U5/1 M5 9.4 7.5 11.7 5.3 3.7 21.3 4.2 10.1 4 5.5 1.8 4.6 0,820
RP-U6 M6 9.4 8.1 12.3 6.4 4.7 22.9 4.2 10.1 4 5.5 1.8 4.6 0,730
RP-U6/1 M6 12 9.2 13.4 6.4 7.1 26.4 4.2 10.1 4 5.5 1.8 4.6 1,229
RP-U8 M8 14 10 14.2 8.4 6.3 26.4 4.2 10.1 4 5.5 1.8 4.6 1,280
RP-U10 M10 17.5 13.05 19.7 10.5 7.75 30.9 4.2 10.1 4 5.5 1.8 4.6 1,500
RP-U12 M12 20 15.5 19.7 13 9 34.6 4.2 10.1 4 5.5 1.8 4.6 1,640
BP-U
Insulated cover color Blue
Range of cable cross section 1.5 ÷ 2.5 mm²
Weight and dimensions
tipo Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
BP-U3 M3 5.5 5.5 9.7 3.2 4 19.6 4.2 10.1 4.9 6.4 2.4 4.6 0,680
BP-U3.5 M3.5 6.4 6.5 10.7 3.7 3.8 20.4 4.2 10.1 4.9 6.4 2.4 4.6 0,720
BP-U3.5/1 M3.5 7.2 6.5 10.7 3.7 3.8 20.4 4.2 10.1 4.9 6.4 2.4 4.6 0,778
BP-U4 M4 6.5 7.5 11.7 4.3 3.7 21.3 4.2 10.1 4.9 6.4 2.4 4.6 0,780
BP-U4/1 M4 8.5 7.5 11.7 4.3 3.7 21.3 4.2 10.1 4.9 6.4 2.4 4.6 0,840
BP-U4/2 M4 7.5 7.5 11.7 4.3 3.7 21.3 4.2 10.1 4.9 6.4 2.4 4.6 0,843
BP-U5 M5 8.5 7.5 11.7 5.3 3.7 21.3 4.2 10.1 4.9 6.4 2.4 4.6 0,775
BP-U6 M6 9.4 8.1 12.3 6.4 4.7 22.9 4.2 10.1 4.9 6.4 2.4 4.6 0,840
BP-U6/1 M6 12 9.2 13.4 6.4 7.1 26.4 4.2 10.1 4.9 6.4 2.4 4.6 1,280
BP-U8 M8 14 10 14.2 8.4 6.3 26.4 4.2 10.1 4.9 6.4 2.4 4.6 1,434
BP-U10 M10 17.5 13.05 17.25 10.5 7.75 30.9 4.2 10.1 4.9 6.4 2.4 4.6 1,580
BP-U12 M12 20 15.5 19.7 13 9 34.6 4.2 10.1 4.9 6.4 2.4 4.6 1,880
GP-U
Insulated cover color Yellow
Range of cable cross section 4 ÷ 6 mm²
Weight and dimensions
tipo Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
GP-U3.5 M3.5 7.5 8.5 14.9 3.7 3.9 26.5 6.4 14.1 6.8 8.1 3.6 7 1,759
GP-U4 M4 7.5 8 14.4 4.3 4.4 26.5 6.4 14.1 6.8 8.1 3.6 7 1,660
GP-U5 M5 9.5 8 14.4 5.6 4.4 26.5 6.4 14.1 6.8 8.1 3.6 7 1,780
GP-U6 M6 10 11 17.4 6.4 5.5 30.6 6.4 14.1 6.8 8.1 3.6 7 2,034
GP-U8 M8 13.5 12 18.4 8.4 8 34.1 6.4 14.1 6.8 8.1 3.6 7 2,360
GP-U10 M10 15.5 13 19.4 10.5 8 35.1 6.4 14.1 6.8 8.1 3.6 7 2,400
GP-U10/1 M10 17.5 13.85 20.25 10.5 7.75 35.7 6.4 14.1 6.8 8.1 3.6 7 2,722
GP-U12 M12 21 15.1 21.5 13 9.5 38.7 6.4 14.1 6.8 8.1 3.6 7 3,120
GP-U14 M14 23 16.1 22.5 15 10.5 40.7 6.4 14.1 6.8 8.1 3.6 7 3,320
GP-U16 M16 26 17.1 23.5 17 11.5 42.7 6.4 14.1 6.8 8.1 3.6 7 3,790

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data