PKET
Gallery
PKET
Description
The PKET series insulated wire ferrules enable reliable connections on copper conductors.
They are manufactured from high-purity electrolytic copper tubing and undergo annealing and electrolytic tin-plating processes to facilitate crimping and increase resistance to mechanical stress.
They feature a halogen-free PA6 insulating sleeve, which helps keep conductor strands compact and improves connection reliability.
The wire ferrules of the PKET series are UL-certified and comply with the EN 45545-2 standard. They are the ideal solution for facilitating conductor insertion into terminals with limited available space, while keeping copper strands compact.
Read all
Close
They are manufactured from high-purity electrolytic copper tubing and undergo annealing and electrolytic tin-plating processes to facilitate crimping and increase resistance to mechanical stress.
They feature a halogen-free PA6 insulating sleeve, which helps keep conductor strands compact and improves connection reliability.
The wire ferrules of the PKET series are UL-certified and comply with the EN 45545-2 standard. They are the ideal solution for facilitating conductor insertion into terminals with limited available space, while keeping copper strands compact.
Common features in table.
Features
Details by type in expandable section below.
Minimum operating temperature
-4 °F
Maximum operating temperature
221 °F
Threshold of operating temperature for short periods
230 °F
Easy insertion input
Yes
Number of cables that can be inserted
2
Conductor body material
Electrolitic copper with purity above 99.95%
Insulated cover material
Polypropylene
Annealing
Yes
Halogen free
Yes
Customs code
85369010
ROHS compliant
Yes
PKET
| Technical information | Weight and dimensions | Logistic | Certifications | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| tipo | Insulated cover color | Range of cable cross section [awg/kcmil] | C [in] | Ø2 [in] | Cable stripping length [in] | Ø1 [in] | P [in] | L [in] | Internal width of cover [in] | Unit in minimal packaging [pce] | Unit in standard packaging [pce] | Self-extinguishing fire class according to UL 94 |
| PKET508 | white | 20 AWG | 0.28 | 0.09 | 0.31 | 0.07 | 0.31 | 0.59 | 0.18 | 500 | 5000 | V2 |
| PKET7508 | blue | 20 AWG | 0.28 | 0.11 | 0.31 | 0.08 | 0.31 | 0.59 | 0.21 | 500 | 5000 | |
| PKET7512 | blue | 20 AWG | 0.28 | 0.11 | 0.47 | 0.08 | 0.47 | 0.75 | 0.21 | 500 | 5000 | |
| PKET108 | red | 18 AWG | 0.28 | 0.13 | 0.31 | 0.09 | 0.31 | 0.59 | 0.21 | 500 | 5000 | V2 |
| PKET112 | red | 18 AWG | 0.28 | 0.13 | 0.47 | 0.09 | 0.47 | 0.75 | 0.21 | 500 | 5000 | |
| PKET1508 | black | 16 AWG | 0.31 | 0.14 | 0.31 | 0.1 | 0.31 | 0.63 | 0.26 | 500 | 4000 | V2 |
| PKET1512 | black | 16 AWG | 0.31 | 0.14 | 0.47 | 0.1 | 0.47 | 0.79 | 0.26 | 500 | 5000 | |
| PKET2510 | grey | 14 AWG | 0.35 | 0.16 | 0.39 | 0.13 | 0.39 | 0.75 | 0.3 | 250 | 2500 | V2 |
| PKET2512 | grey | 14 AWG | 0.35 | 0.16 | 0.47 | 0.13 | 0.47 | 0.87 | 0.3 | 250 | 2500 | |
| PKET412 | orange | 12 AWG | 0.43 | 0.19 | 0.47 | 0.17 | 0.47 | 0.91 | 0.34 | 100 | 1000 | |
| PKET614 | green | 10 AWG | 0.43 | 0.24 | 0.55 | 0.21 | 0.55 | 0.98 | 0.39 | 100 | 1000 | |
| PKET1014 | brown | 8 AWG | 0.47 | 0.28 | 0.55 | 0.27 | 0.55 | 1.02 | 0.51 | 100 | 1000 | |
PKET508
Insulated cover color
white
Range of cable cross section [awg/kcmil]
20 AWG
C [in]
0.28
Ø2 [in]
0.09
Cable stripping length [in]
0.31
Ø1 [in]
0.07
P [in]
0.31
L [in]
0.59
Internal width of cover [in]
0.18
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
Self-extinguishing fire class according to UL 94
V2
PKET7508
Insulated cover color
blue
Range of cable cross section [awg/kcmil]
20 AWG
C [in]
0.28
Ø2 [in]
0.11
Cable stripping length [in]
0.31
Ø1 [in]
0.08
P [in]
0.31
L [in]
0.59
Internal width of cover [in]
0.21
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
Self-extinguishing fire class according to UL 94
–
PKET7512
Insulated cover color
blue
Range of cable cross section [awg/kcmil]
20 AWG
C [in]
0.28
Ø2 [in]
0.11
Cable stripping length [in]
0.47
Ø1 [in]
0.08
P [in]
0.47
L [in]
0.75
Internal width of cover [in]
0.21
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
Self-extinguishing fire class according to UL 94
–
PKET108
Insulated cover color
red
Range of cable cross section [awg/kcmil]
18 AWG
C [in]
0.28
Ø2 [in]
0.13
Cable stripping length [in]
0.31
Ø1 [in]
0.09
P [in]
0.31
L [in]
0.59
Internal width of cover [in]
0.21
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
Self-extinguishing fire class according to UL 94
V2
PKET112
Insulated cover color
red
Range of cable cross section [awg/kcmil]
18 AWG
C [in]
0.28
Ø2 [in]
0.13
Cable stripping length [in]
0.47
Ø1 [in]
0.09
P [in]
0.47
L [in]
0.75
Internal width of cover [in]
0.21
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
Self-extinguishing fire class according to UL 94
–
PKET1508
Insulated cover color
black
Range of cable cross section [awg/kcmil]
16 AWG
C [in]
0.31
Ø2 [in]
0.14
Cable stripping length [in]
0.31
Ø1 [in]
0.1
P [in]
0.31
L [in]
0.63
Internal width of cover [in]
0.26
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
4000
Self-extinguishing fire class according to UL 94
V2
PKET1512
Insulated cover color
black
Range of cable cross section [awg/kcmil]
16 AWG
C [in]
0.31
Ø2 [in]
0.14
Cable stripping length [in]
0.47
Ø1 [in]
0.1
P [in]
0.47
L [in]
0.79
Internal width of cover [in]
0.26
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
Self-extinguishing fire class according to UL 94
–
PKET2510
Insulated cover color
grey
Range of cable cross section [awg/kcmil]
14 AWG
C [in]
0.35
Ø2 [in]
0.16
Cable stripping length [in]
0.39
Ø1 [in]
0.13
P [in]
0.39
L [in]
0.75
Internal width of cover [in]
0.3
Unit in minimal packaging [pce]
250
Unit in standard packaging [pce]
2500
Self-extinguishing fire class according to UL 94
V2
PKET2512
Insulated cover color
grey
Range of cable cross section [awg/kcmil]
14 AWG
C [in]
0.35
Ø2 [in]
0.16
Cable stripping length [in]
0.47
Ø1 [in]
0.13
P [in]
0.47
L [in]
0.87
Internal width of cover [in]
0.3
Unit in minimal packaging [pce]
250
Unit in standard packaging [pce]
2500
Self-extinguishing fire class according to UL 94
–
PKET412
Insulated cover color
orange
Range of cable cross section [awg/kcmil]
12 AWG
C [in]
0.43
Ø2 [in]
0.19
Cable stripping length [in]
0.47
Ø1 [in]
0.17
P [in]
0.47
L [in]
0.91
Internal width of cover [in]
0.34
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1000
Self-extinguishing fire class according to UL 94
–
PKET614
Insulated cover color
green
Range of cable cross section [awg/kcmil]
10 AWG
C [in]
0.43
Ø2 [in]
0.24
Cable stripping length [in]
0.55
Ø1 [in]
0.21
P [in]
0.55
L [in]
0.98
Internal width of cover [in]
0.39
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1000
Self-extinguishing fire class according to UL 94
–
PKET1014
Insulated cover color
brown
Range of cable cross section [awg/kcmil]
8 AWG
C [in]
0.47
Ø2 [in]
0.28
Cable stripping length [in]
0.55
Ø1 [in]
0.27
P [in]
0.55
L [in]
1.02
Internal width of cover [in]
0.51
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1000
Self-extinguishing fire class according to UL 94
–
Follow us
Subscribe to CEMBRE newsletter and stay tuned
Thank you, your request has been send successfully
You'll be contact soon by our commercial staff
Print label service
Fill in the form and follow the instructions to request the label print service
Thank you, your request has been send successfully
You'll be contact soon by our commercial staff