F-U FORK TERMINAL

FORK TERMINAL, PRE-INSULATED WITH PVC, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
These terminals are particularly recommended for use with fl exible conductors. They are manufactured from electrolytic copper tube with a purity greater than 99.9% and with dimension so as to ensure both a good electrical connection and an adequate resistance to vibrations and traction; they are annealed and tin plated. For the same cable section are available different types of connectors with PA6.6 sleeve entry of different diameters so as to accept conductors with various insulation thickness. The insulated sleeve additionally will accept the conductor so avoiding a sudden bending of the conductor itself at the connector entry, highly increasing its resistance to the mechanical solicitations that could break the conductor strands. The operating temperature range is – 20 to + 115°C (Surge + 130°C).
Read all Close

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
75   °C
Threshold of operating temperature for short periods
90   °C
Type of insulation
partial
Easy insertion input
Yes
Surface treatment
tin plating
Crimping geometry
radial
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Insulated cover material
Polyvinylchloride PVC
Annealing
Yes
Unit in minimal packaging
100   PCE
Customs code
85369010
ROHS compliant
Yes
Self-extinguishing fire class according to UL 94
V0

drwr-dim
RF-U
Insulated cover color red
Range of cable cross section [mm²] 0.25 ÷ 1.5
Weight and dimensions Logistic
tipo
tipo
Screw diameter
Screw diameter
B [mm]
B [mm]
M [mm]
M [mm]
I [mm]
I [mm]
D [mm]
D [mm]
N [mm]
N [mm]
Tightening torque (high conductivity screw) [nm]
Tightening torque (high conductivity screw) [nm]
Tightening torque (8.8 grade screw) [nm]
Tightening torque (8.8 grade screw) [nm]
L [mm]
L [mm]
A [mm]
A [mm]
C [mm]
C [mm]
Ø2 [mm]
Ø2 [mm]
Ø3 [mm]
Ø3 [mm]
Ø [mm]
Ø [mm]
Cable stripping length [mm]
Cable stripping length [mm]
Unit in standard packaging [pce]
Unit in standard packaging [pce]
RF-U3 M3 5.5 5.5 9.7 3.2 4 0.5 0.5 19.5 4.2 10.1 4 5 1.8 5 3000
RF-U3.5 M3.5 6 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4 5 1.8 5 3000
RF-U3.5/1 M3.5 7.2 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4 5 1.8 5 3000
RF-U3.5/2 M3.5 6.4 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4 5 1.8 5 3000
RF-U4 M4 6.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4 5 1.8 5 3000
RF-U4/1 M4 8.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4 5 1.8 5 3000
RF-U4/2 M4 7.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4 5 1.8 5 3000
RF-U5 M5 8.5 7.5 11.7 5.3 3.7 21.2 4.2 10.1 4 5 1.8 5 2500
RF-U5/1 M5 9.4 7.5 11.7 5.3 3.7 21.2 4.2 10.1 4 5 1.8 5 3000
RF-U6 M6 9.4 8.1 12.3 6.4 4.7 5 7 22.8 4.2 10.1 4 5 1.8 5 2000
RF-U6/1 M6 12 9.2 13.4 6.4 7.1 5 7 26.4 4.2 10.1 4 5 1.8 5 2000
RF-U8 M8 14 10 14.2 8.4 6.3 10 20 26.4 4.2 10.1 4 5 1.8 5 2000
RF-U10 M10 17.5 13.05 17.25 10.5 7.7 20 35 30.8 4.2 10.1 4 5 1.8 5 1500
RF-U12 M12 20 15.5 19.7 13 9 40 50 34.5 4.2 10.1 4 5 1.8 5 1500
BF-U
Insulated cover color blue
Range of cable cross section [mm²] 1.5 ÷ 2.5
Weight and dimensions Logistic
tipo
tipo
Screw diameter
Screw diameter
B [mm]
B [mm]
M [mm]
M [mm]
I [mm]
I [mm]
D [mm]
D [mm]
N [mm]
N [mm]
Tightening torque (high conductivity screw) [nm]
Tightening torque (high conductivity screw) [nm]
Tightening torque (8.8 grade screw) [nm]
Tightening torque (8.8 grade screw) [nm]
L [mm]
L [mm]
A [mm]
A [mm]
C [mm]
C [mm]
Ø2 [mm]
Ø2 [mm]
Ø3 [mm]
Ø3 [mm]
Ø [mm]
Ø [mm]
Cable stripping length [mm]
Cable stripping length [mm]
Unit in standard packaging [pce]
Unit in standard packaging [pce]
BF-U3 M3 5.5 5.5 9.7 3.2 4 0.5 0.5 19.5 4.2 10.1 4.9 6.4 2.4 5 2500
BF-U3.5 M3.5 6.4 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4.9 6.4 2.4 5 2500
BF-U3.5/1 M3.5 7.2 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4.9 6.4 2.4 5 3000
BF-U4 M4 6.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4.9 6.4 2.4 5 2500
BF-U4/1 M4 8.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4.9 6.4 2.4 5 2000
BF-U4/2 M4 7.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4.9 6.4 2.4 5 2000
BF-U5 M5 8.5 7.5 11.7 5.3 3.7 21.2 4.2 10.1 4.9 6.4 2.4 5 2000
BF-U5/2 M5 12 11.3 15.5 5.3 5 26.3 4.2 10.1 4.9 6.4 2.4 5 1500
BF-U6 M6 9.4 8.1 12.3 6.4 4.7 5 7 22.8 4.2 10.1 4.9 6.4 2.4 5 2000
BF-U6/1 M6 12 9.2 13.4 6.4 7.1 5 7 26.3 4.2 10.1 4.9 6.4 2.4 5 2000
BF-U8 M8 14 10 14.2 8.4 6.3 10 20 26.3 4.2 10.1 4.9 6.4 2.4 5 1500
BF-U10 M10 17.5 13.05 17.25 10.5 7.75 20 35 30.8 4.2 10.1 4.9 6.4 2.4 5 1000
BF-U12 M12 20 15.5 19.7 13 9 40 50 34.5 4.2 10.1 4.9 6.4 2.4 5 1000
GF-U
Insulated cover color yellow
Range of cable cross section [mm²] 4 ÷ 6
Weight and dimensions Logistic
tipo
tipo
Screw diameter
Screw diameter
B [mm]
B [mm]
M [mm]
M [mm]
I [mm]
I [mm]
D [mm]
D [mm]
N [mm]
N [mm]
Tightening torque (high conductivity screw) [nm]
Tightening torque (high conductivity screw) [nm]
Tightening torque (8.8 grade screw) [nm]
Tightening torque (8.8 grade screw) [nm]
L [mm]
L [mm]
A [mm]
A [mm]
C [mm]
C [mm]
Ø2 [mm]
Ø2 [mm]
Ø3 [mm]
Ø3 [mm]
Ø [mm]
Ø [mm]
Cable stripping length [mm]
Cable stripping length [mm]
Unit in standard packaging [pce]
Unit in standard packaging [pce]
GF-U3.5 M3.5 7.5 8.5 14.9 3.7 3.9 26.5 8 14.1 6.6 8.1 3.6 7 1000
GF-U4 M4 7.5 8 14.4 4.3 4.4 26.5 8 14.1 6.6 8.1 3.6 7 1000
GF-U5 M5 9.5 8 14.4 5.3 4.4 26.5 8 14.1 6.6 8.1 3.6 7 1000
GF-U6 M6 10 11 17.4 6.4 5.5 5 7 30.6 8 14.1 6.6 8.1 3.6 7 1000
GF-U8 M8 13.5 12 18.4 8.4 8 10 20 34.1 8 14.1 6.6 8.1 3.6 7 800
GF-U10 M10 15.5 13 19.4 10.5 8 20 35 35.1 8 14.1 6.6 8.1 3.6 7 1000
GF-U10/1 M10 17.5 13.85 20.25 10.5 7.75 20 35 35.7 8 14.1 6.6 8.1 3.6 7 1000
GF-U12 M12 21 15.1 21.5 13 9.5 40 50 38.7 8 14.1 6.6 8.1 3.6 7 500
GF-U14 M14 23 16.1 22.5 15 10.5 65 70 40.7 8 14.1 6.6 8.1 3.6 7 500
GF-U16 M16 26 17.1 23.5 17 11.5 90 90 42.7 8 14.1 6.6 8.1 3.6 7 500

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data