AN EN IN ON UN-M

Description
Insulated ring cable lugs are made from high-purity electrolytic copper tube and undergo annealing and electrolytic tin-plating processes to increase resistance to mechanical stress and improve the durability of the connection.
They are fitted with a halogen-free PA6.6 insulated cover with an internal funnel-shaped profile, designed to facilitate the insertion of the conductor and prevent the wires from being crimped during wiring.
The cover incorporates an inspection hole to check that the conductor has been inserted correctly.
Read all Close

Common features in table.

Features
Details by type in expandable section below.
  • Classification and data ordering
Customs code
85369010

AN EN IN ON UN-M
Technical information Material composition and treatments Weight and dimensions Logistic Certifications
tipo Minimum operating temperature [°c] Maximum operating temperature [°c] Threshold of operating temperature for short periods [°c] Spy hole Number of holes on the palm Insulated cover colour Type of insulation Easy insertion input Surface treatment Screw pitch Range of cable cross section (flexible) [mm²] Range of cable cross section (low stranded) [mm²] Conductor body material Insulated cover material Annealing Halogen free ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Unit in minimal packaging [pce] Unit in standard packaging [pce] ROHS compliant EN 45545-2 certification (r22)
EN06-M3 -20 115 130 Yes 1 blue partial Yes tin plating M3 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 3.2 6 3.5 4.5 13.5 27 6 16 6.9 8.5 2.4 7 100 2000 Yes HL2
EN06-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 7.5 4 5 14 28 6 16 6.9 8.5 2.4 7 100 1500 Yes HL2
EN06-M3.5 -20 115 130 Yes 1 blue partial Yes tin plating M3.5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 3.7 6.5 3.5 4.5 13.5 27 6 16 6.9 8.5 2.4 7 100 2000 HL2
EN06-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 8.5 4.5 5.5 14.5 29 6 16 6.9 8.5 2.4 7 100 1500 Yes HL2
EN06-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 9 5 6 15 30 6 16 6.9 8.5 2.4 7 100 1500 Yes HL2
EN06-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 12 8 9 18 36 6 16 6.9 8.5 2.4 7 100 1000 Yes HL2
IN06-M3 -20 115 130 Yes 1 green partial Yes tin plating M3 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 3.2 6 3.5 4.5 13.5 25.1 6 15.1 5.3 5.5 2.4 7 100 2500 Yes HL2
IN06-M3.5 -20 115 130 Yes 1 green partial Yes tin plating M3.5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 3.7 6.5 3.5 4.5 13.5 26.1 6 15.1 5.3 5.5 2.4 7 100 100 HL2
IN06-M4 -20 115 130 Yes 1 green partial Yes tin plating M4 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 7.5 4 5 14 26.1 6 15.1 5.3 5.5 2.4 7 100 2000 Yes HL2
IN06-M5 -20 115 130 Yes 1 green partial Yes tin plating M5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 8.5 4.5 5.5 14.5 27.1 6 15.1 5.3 5.5 2.4 7 100 2000 Yes HL2
IN06-M6 -20 115 130 Yes 1 green partial Yes tin plating M6 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 9 5 6 15 28.1 6 15.1 5.3 5.5 2.4 7 100 2000 Yes HL2
IN06-M8 -20 115 130 Yes 1 green partial Yes tin plating M8 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 12 8 9 18 34.1 6 15.1 5.3 5.5 2.4 7 100 1000 Yes HL2
AN06-M3 -20 115 130 Yes 1 blue partial Yes tin plating M3 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 3.2 6 3.5 4.5 13.5 23.8 6 12.8 4.1 5.5 2.4 7 100 3000 Yes HL2
AN06-M3.5 -20 115 130 Yes 1 blue partial Yes tin plating M3.5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 3.7 6.5 3.5 4.5 13.5 23.8 6 12.8 4.1 5.5 2.4 7 100 3000 Yes HL2
AN06-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 7.5 4 5 14 24.8 6 12.8 4.1 5.5 2.4 7 100 2500 Yes HL2
AN06-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 8.5 4.5 5.5 14.5 25.8 6 12.8 4.1 5.5 2.4 7 100 3000 Yes HL2
AN06-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 9 5 6 15 26.8 6 12.8 4.1 5.5 2.4 7 100 3000 Yes HL2
AN06-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 12 8 9 18 32.8 6 12.8 4.1 5.5 2.4 7 100 2000 Yes HL2
ENR06-M3 -20 115 130 Yes 1 blue partial Yes tin plating M3 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 3.2 6 3.5 4.5 13.5 26 6 16.1 6 7.5 2.4 7 100 2000 Yes HL2
ENR06-M3.5 -20 115 130 Yes 1 blue partial Yes tin plating M3.5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 3.7 6.5 3.5 4.5 13.5 27.1 6 16.1 6 7.5 2.4 7 100 100 HL2
ENR06-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 7.5 4 5 14 28.1 6 16.1 6 7.5 2.4 7 100 2000 HL2
ENR06-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 8.5 4.5 5.5 14.5 28 6 16.1 6 7.5 2.4 7 100 2000 Yes HL2
ENR06-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 9 5 6 15 29 6 16.1 6 7.5 2.4 7 100 1500 Yes HL2
ENR06-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 1.5 - 2.5 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 12 8 9 18 35 6 16.1 6 7.5 2.4 7 100 100 Yes HL2
IN1-M3 -20 115 130 Yes 1 transparent partial Yes tin plating M3 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 3.2 7.5 3.5 4.5 17 30.6 8 18.1 6.6 8 3.6 9 100 1500 HL2
IN1-M4 -20 115 130 Yes 1 transparent partial Yes tin plating M4 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 8 4 5 17.5 31.6 8 18.1 6.6 8 3.6 9 100 1000 Yes HL2
IN1-M5 -20 115 130 Yes 1 transparent partial Yes tin plating M5 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 9 6 6.5 19 35.1 8 18.1 6.6 8 3.6 9 100 1000 Yes HL2
IN1-M6 -20 115 130 Yes 1 transparent partial Yes tin plating M6 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11 6 7 19.5 35.6 8 18.1 6.6 8 3.6 9 100 1000 Yes HL2
IN1-M8 -20 115 130 Yes 1 transparent partial Yes tin plating M8 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 14 8 9 21.5 39.6 8 18.1 6.6 8 3.6 9 100 1000 Yes HL2
IN1-M10 -20 115 130 Yes 1 transparent partial Yes tin plating M10 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 16.5 10 11 24 44.1 8 18.1 6.6 8 3.6 9 100 500 Yes HL2
AN1-M3 -20 115 130 Yes 1 yellow partial Yes tin plating M3 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 3.2 7.5 3.5 4.5 17 27.5 8 15 5.3 6.8 3.6 9 100 1000 HL2
AN1-M3.5 -20 115 130 Yes 1 yellow partial Yes tin plating M3.5 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 3.7 7.5 3.5 4.5 17 27.5 8 15 5.3 6.8 3.6 9 100 1000 HL2
AN1-M4 -20 115 130 Yes 1 yellow partial Yes tin plating M4 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 8 4 5 17.5 28.5 8 15 5.3 6.8 3.6 9 100 1000 Yes HL2
AN1-M5 -20 115 130 Yes 1 yellow partial Yes tin plating M5 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 9 6 6.5 19 32 8 15 5.3 6.8 3.6 9 100 1000 Yes HL2
AN1-M6 -20 115 130 Yes 1 yellow partial Yes tin plating M6 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11 6 7 19.5 32.5 8 15 5.3 6.8 3.6 9 100 1000 Yes HL2
AN1-M8 -20 115 130 Yes 1 yellow partial Yes tin plating M8 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 14 8 9 21.5 36.5 8 15 5.3 6.8 3.6 9 100 1000 Yes HL2
AN1-M10 -20 115 130 Yes 1 yellow partial Yes tin plating M10 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 16.5 10 11 24 41 8 15 5.3 6.8 3.6 9 100 1000 Yes HL2
EN1-M3 -20 115 130 Yes 1 red partial Yes tin plating M3 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 3.2 7.5 3.5 4.5 17 35.8 8 23.3 14.1 15.5 3.6 9 100 100 HL2
EN1-M3.5 100 100
EN1-M4 -20 115 130 Yes 1 red partial Yes tin plating M4 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 8 4 5 17.5 36.8 8 23.3 14.1 15.5 3.6 9 100 500 Yes HL2
EN1-M5 -20 115 130 Yes 1 red partial Yes tin plating M5 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 9 6 6.5 19 40.3 8 23.3 14.1 15.5 3.6 9 100 500 Yes HL2
EN1-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 11 6 7 19.5 40.8 8 23.3 14.1 15.5 3.6 9 100 400 Yes HL2
EN1-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 14 8 9 21.5 44.8 8 23.3 14.1 15.5 3.6 9 100 400 Yes HL2
EN1-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 16.5 10 11 24 49.3 8 23.3 14.1 15.5 3.6 9 100 400 Yes HL2
ON1-M3 -20 115 130 Yes 1 blue partial Yes tin plating M3 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 3.2 7.5 3.5 4.5 17 32.5 8 20 7.6 9 3.6 9 100 1000 HL2
ON1-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 8 4 5 17.5 33.5 8 20 7.6 9 3.6 9 100 1000 Yes HL2
ON1-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 9 6 6.5 19 37 8 20 7.6 9 3.6 9 100 1000 Yes HL2
ON1-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 11 6 7 19.5 37.5 8 20 7.6 9 3.6 9 100 1000 Yes HL2
ON1-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 14 8 9 21.5 41.5 8 20 7.6 9 3.6 9 100 1000 Yes HL2
ON1-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 16.5 10 11 24 46 8 20 7.6 9 3.6 9 100 500 Yes HL2
UN1-M3 -20 115 130 Yes 1 blue partial Yes tin plating M3 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 3.2 7.5 3.5 4.5 17 32.1 8 19.6 8.7 10 3.6 9 100 1000 HL2
UN1-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 8 4 5 17.5 33.1 8 19.6 8.7 10 3.6 9 100 1000 Yes HL2
UN1-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 9 6 6.5 19 36.6 8 19.6 8.7 10 3.6 9 100 1000 Yes HL2
UN1-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11 6 7 19.5 37.1 8 19.6 8.7 10 3.6 9 100 1000 Yes HL2
UN1-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 14 8 9 21.5 41.4 8 19.6 8.7 10 3.6 9 100 1000 Yes HL2
UN1-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 4 - 6 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 16.5 10 11 24 45.6 8 19.6 8.7 10 3.6 9 100 500 Yes HL2
IN2-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 10 4 5 18.5 38 8 23.8 10.8 12 4.6 9 100 500 HL2
IN2-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 10 6 6.5 20 41.5 8 23.8 10.8 12 4.6 9 100 500 Yes HL2
IN2-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11 6 7 20.5 42 8 23.8 10.8 12 4.6 9 100 500 Yes HL2
IN2-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 15 8 9 22.5 46 8 23.8 10.8 12 4.6 9 100 500 Yes HL2
IN2-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 18 10 11 24.5 50 8 23.8 10.8 12 4.6 9 100 500 Yes HL2
IN2-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 19 12 14 27.5 55 8 23.8 10.8 12 4.6 9 100 100 Yes HL2
AN2-M4 -20 115 130 Yes 1 red partial Yes tin plating M4 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 10 4 5 18.5 34.1 8 21 8 9.5 4.6 9 100 500 Yes HL2
AN2-M5 -20 115 130 Yes 1 red partial Yes tin plating M5 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 10 6 6.5 20 37.6 8 21 8 9.5 4.6 9 100 500 Yes HL2
AN2-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11 6 7 20.5 38.1 8 21 8 9.5 4.6 9 100 500 Yes HL2
AN2-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 15 8 9 22.5 42.1 8 21 8 9.5 4.6 9 100 500 Yes HL2
AN2-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 18 10 11 24.5 46.1 8 21 8 9.5 4.6 9 100 500 Yes HL2
AN2-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 19 12 14 27.5 51 8 21 8 9.5 4.6 9 100 500 HL2
EN2-M4 -20 115 130 Yes 1 red partial Yes tin plating M4 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 10 4 5 18.5 38 8 25.1 15.1 16.7 4.6 9 100 100 Yes HL2
EN2-M5 -20 115 130 Yes 1 red partial Yes tin plating M5 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 10 6 6.5 20 41.5 8 25.1 15.1 16.7 4.6 9 100 300 HL2
EN2-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 11 6 7 20.5 42 8 25.1 15.1 16.7 4.6 9 100 300 Yes HL2
EN2-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 15 8 9 22.5 46 8 25.1 15.1 16.7 4.6 9 100 300 Yes HL2
EN2-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 18 10 11 24.5 50 8 25.1 15.1 16.7 4.6 9 100 300 Yes HL2
EN2-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 19 12 14 27.5 55 8 25.1 15.1 16.7 4.6 9 100 200 Yes HL2
ENR2-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 10 4 5 18.5 39 8 26.1 12.5 14 4.6 9 100 100 HL2
ENR2-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 10 6 6.5 20 42.5 8 26.1 12.5 14 4.6 9 100 300 Yes HL2
ENR2-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 11 6 7 20.5 43 8 26.1 12.5 14 4.6 9 100 300 Yes HL2
ENR2-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 15 8 9 22.5 47 8 26.1 12.5 14 4.6 9 100 300 HL2
ENR2-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 18 10 11 24.5 51 8 26.1 12.5 14 4.6 9 100 300 Yes HL2
ENR2-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 10 10 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 19 12 14 27.5 56 8 26.1 12.5 14 4.6 9 100 100 HL2
AN3-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 11.5 4 5 21.5 38.6 11.5 24 9.2 10.5 5.8 13 100 500 Yes HL2
AN3-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 11.5 6 6.5 23 42.1 11.5 24 9.2 10.5 5.8 13 100 500 Yes HL2
AN3-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11.5 6 7 23.5 42.6 11.5 24 9.2 10.5 5.8 13 100 500 Yes HL2
AN3-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 15 8 9 25.5 46.6 11.5 24 9.2 10.5 5.8 13 100 500 Yes HL2
AN3-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 18 10 11 27.5 50.6 11.5 24 9.2 10.5 5.8 13 100 400 Yes HL2
AN3-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 20 12 14 32 57.1 11.5 24 9.2 10.5 5.8 13 100 500 Yes HL2
EN3-M4 -20 115 130 Yes 1 blue partial Yes tin plating M4 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 4.3 11.5 4 5 21.5 40.5 11.5 25.7 11.7 13.4 5.8 13 100 500 HL2
EN3-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 11.5 6 6.5 23 44 11.5 25.7 11.7 13.4 5.8 13 100 400 Yes HL2
EN3-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 11.5 6 7 23.5 44.5 11.5 25.7 11.7 13.4 5.8 13 100 400 Yes HL2
EN3-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 15 8 9 25.5 48.5 11.5 25.7 11.7 13.4 5.8 13 100 300 Yes HL2
EN3-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 18 10 11 27.5 52.5 11.5 25.7 11.7 13.4 5.8 13 100 300 Yes HL2
EN3-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 20 12 14 32 59 11.5 25.7 11.7 13.4 5.8 13 100 100 Yes HL2
IN3-M4 -20 115 130 Yes 1 red partial Yes tin plating M4 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 11.5 4 5 21.5 42.8 11.5 27.9 16.9 18.6 5.8 13 100 200 HL2
IN3-M5 -20 115 130 Yes 1 red partial Yes tin plating M5 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 11.5 6 6.5 23 46.3 11.5 27.9 16.9 18.6 5.8 13 100 200 Yes HL2
IN3-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 11.5 6 7 23.5 46.8 11.5 27.9 16.9 18.6 5.8 13 100 200 Yes HL2
IN3-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 15 8 9 25.5 50.8 11.5 27.9 16.9 18.6 5.8 13 100 200 Yes HL2
IN3-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 18 10 11 27.5 54.8 11.5 27.9 16.9 18.6 5.8 13 100 200 Yes HL2
IN3-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 16 16 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 20 12 14 32 44 11.5 27.9 16.9 18.6 5.8 13 100 200 HL2
AN5-M4 -20 115 130 Yes 1 yellow partial Yes tin plating M4 25 25 Electrolitic copper with purity above 99.95% Polyamide Yes 4.3 14 4 5 24 41 10.5 25 11.1 13 7 12 100 100 Yes HL2
AN5-M5 -20 115 130 Yes 1 yellow partial Yes tin plating M5 25 25 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 14 6 6.5 25.5 44.5 10.5 25 11.1 13 7 12 100 300 Yes HL2
AN5-M6 -20 115 130 Yes 1 yellow partial Yes tin plating M6 25 25 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 14 6 7 26 45 10.5 25 11.1 13 7 12 100 300 Yes HL2
AN5-M8 -20 115 130 Yes 1 yellow partial Yes tin plating M8 25 25 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 15 8 9 28 49 10.5 25 11.1 13 7 12 100 300 Yes HL2
AN5-M10 -20 115 130 Yes 1 yellow partial Yes tin plating M10 25 25 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 18 10 11 30 53 10.5 25 11.1 13 7 12 100 300 Yes HL2
AN5-M12 -20 115 130 Yes 1 yellow partial Yes tin plating M12 25 25 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 21 12 14 33 58 10.5 25 11.1 13 7 12 100 300 Yes HL2
AN7-M5 -20 115 130 Yes 1 red partial Yes tin plating M5 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 17 6 6.5 28 47.5 13.2 27.5 11.9 14 8.9 15 100 200 HL2
AN7-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 17 6 7 28.5 48 13.2 27.5 11.9 14 8.9 15 100 200 Yes HL2
AN7-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 17 8 9 30.5 52 13.2 27.5 11.9 14 8.9 15 100 200 Yes HL2
AN7-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 19 10 11 32.5 56 13.2 27.5 11.9 14 8.9 15 50 100 Yes HL2
AN7-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 21 12 14 35.5 61 13.2 27.5 11.9 14 8.9 15 100 200 HL2
IN7-M5 -20 115 130 Yes 1 red partial Yes tin plating M5 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 5.3 17 6 6.5 28 56.2 13.2 36.1 18.7 20.5 8.9 15 50 150 HL2
IN7-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 17 6 7 28.5 56.7 13.2 36.1 18.7 20.5 8.9 15 50 150 Yes HL2
IN7-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 17 8 9 30.5 60.7 13.2 36.1 18.7 20.5 8.9 15 50 150 Yes HL2
IN7-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 19 10 11 32.5 64.7 13.2 36.1 18.7 20.5 8.9 15 50 100 Yes HL2
IN7-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 21 12 14 35.5 69.7 13.2 36.1 18.7 20.5 8.9 15 50 100 HL2
EN7-M5 -20 115 130 Yes 1 blue partial Yes tin plating M5 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 5.3 17 6 6.5 28 46.7 13.2 26.5 13 15 8.9 15 100 100 HL2
EN7-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 17 6 7 28.5 47.2 13.2 26.5 13 15 8.9 15 100 200 Yes HL2
EN7-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 17 8 9 30.5 51.2 13.2 26.5 13 15 8.9 15 100 200 Yes HL2
EN7-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 19 10 11 32.5 55.2 13.2 26.5 13 15 8.9 15 100 200 Yes HL2
EN7-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 25 - 35 35 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 21 12 14 35.5 60.2 13.2 26.5 13 15 8.9 15 100 200 Yes HL2
AN10-M6 -20 115 130 Yes 1 transparent partial Yes tin plating M6 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 19 7 8 31.5 53 16.5 30.5 13.8 15.8 10 19 50 200 Yes HL2
AN10-M8 -20 115 130 Yes 1 transparent partial Yes tin plating M8 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 19 8 9 32.5 55 16.5 30.5 13.8 15.8 10 19 50 200 HL2
AN10-M10 -20 115 130 Yes 1 transparent partial Yes tin plating M10 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 20 9.5 11.5 35 59 16.5 30.5 13.8 15.8 10 19 50 200 Yes HL2
AN10-M12 -20 115 130 Yes 1 transparent partial Yes tin plating M12 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 21 12 12 35.5 62 16.5 30.5 13.8 15.8 10 19 50 150 HL2
AN10-M14 -20 115 130 Yes 1 transparent partial Yes tin plating M14 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 15 25 14 16 41.5 70 16.5 30.5 13.8 15.8 10 19 50 100 HL2
AN10-M16 -20 115 130 Yes 1 transparent partial Yes tin plating M16 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 17 26 16 18 43.5 74 16.5 30.5 13.8 15.8 10 19 50 100 HL2
IN10-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 19 7 8 31.5 54.3 16.5 33.8 15 17 10 19 50 100 HL2
IN10-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 19 8 9 32.5 56.3 16.5 33.8 15 17 10 19 50 100 HL2
IN10-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 20 9.5 11.5 35 60.3 16.5 33.8 15 17 10 19 50 150 HL2
IN10-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 21 12 12 35.5 63.3 16.5 33.8 15 17 10 19 50 100 HL2
IN10-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 15 25 14 16 41.5 71.3 16.5 33.8 15 17 10 19 50 50 HL2
IN10-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes 17 26 16 18 43.5 75.3 16.5 33.8 15 17 10 19 50 50 HL2
ENR10-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 19 7 8 31.5 57.5 16.5 37 17.3 19 10 19 50 100 HL2
ENR10-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 19 8 9 32.5 59.5 16.5 37 17.3 19 10 19 50 100 Yes HL2
ENR10-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 20 9.5 11.5 35 63.5 16.5 37 17.3 19 10 19 50 100 Yes HL2
ENR10-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 21 12 12 35.5 66.5 16.5 37 17.3 19 10 19 50 100 HL2
ENR10-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 25 14 16 41.5 74.5 16.5 37 17.3 19 10 19 50 50 HL2
ENR10-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 26 16 18 43.5 78.5 16.5 37 17.3 19 10 19 50 50 HL2
EN10-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 19 7 8 31.5 60.5 16.5 40 20.2 22 10 19 50 100 Yes HL2
EN10-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 19 8 9 32.5 62.5 16.5 40 20.2 22 10 19 50 100 Yes HL2
EN10-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 20 9.5 11.5 35 66.5 16.5 40 20.2 22 10 19 50 100 Yes HL2
EN10-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 21 12 12 35.5 69.5 16.5 40 20.2 22 10 19 50 100 HL2
EN10-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 25 14 16 41.5 77.5 16.5 40 20.2 22 10 19 50 50 Yes HL2
EN10-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 35 50 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 26 16 18 43.5 81.5 16.5 40 20.2 22 10 19 50 100 HL2
IN14-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 21 7 8 37 64 18 39 16.9 19.2 11.3 20 50 100 HL2
IN14-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 21 8 9 38 66 18 39 16.9 19.2 11.3 20 50 100 HL2
IN14-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 21 10 11 40 70 18 39 16.9 19.2 11.3 20 50 100 Yes HL2
IN14-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 22 12 14 43 75 18 39 16.9 19.2 11.3 20 50 100 HL2
IN14-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 15 25 14 16 45 79 18 39 16.9 19.2 11.3 20 50 100 HL2
IN14-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 17 26 16 18 47 83 18 39 16.9 19.2 11.3 20 50 100 HL2
EN14-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 21 7 8 37 68 18 42.9 21.9 24.3 11.3 20 25 50 Yes HL2
EN14-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 21 8 9 38 70 18 42.9 21.9 24.3 11.3 20 25 50 Yes HL2
EN14-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 21 10 11 40 74 18 42.9 21.9 24.3 11.3 20 25 50 Yes HL2
EN14-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 22 12 14 43 79 18 42.9 21.9 24.3 11.3 20 25 50 HL2
EN14-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 25 14 16 45 83 18 42.9 21.9 24.3 11.3 20 25 50 HL2
EN14-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 26 16 18 47 87 18 42.9 21.9 24.3 11.3 20 25 50 HL2
AN14-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 21 7 8 37 61 18 39 16.9 19.2 11.3 20 50 100 Yes HL2
AN14-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 21 8 9 38 63 18 39 16.9 19.2 11.3 20 50 100 HL2
AN14-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 21 10 11 40 67 18 39 16.9 19.2 11.3 20 50 100 Yes HL2
AN14-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 22 12 14 43 72 18 39 16.9 19.2 11.3 20 50 100 HL2
AN14-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 15 25 14 16 45 76 18 39 16.9 19.2 11.3 20 50 100 HL2
AN14-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 50 70 Electrolitic copper with purity above 99.95% Polyamide Yes 17 26 16 18 47 80 18 39 16.9 19.2 11.3 20 50 100 HL2
AN17-M8 -20 115 130 Yes 1 black partial Yes tin plating M8 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 23 8 9 39 65.8 20 40 17.9 20.4 13 22 50 100 HL2
AN17-M10 -20 115 130 Yes 1 black partial Yes tin plating M10 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 23 10 11 41 69.8 20 40 17.9 20.4 13 22 50 100 HL2
AN17-M12 -20 115 130 Yes 1 black partial Yes tin plating M12 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 23 12 14 44 74.8 20 40 17.9 20.4 13 22 25 50 HL2
AN17-M14 -20 115 130 Yes 1 black partial Yes tin plating M14 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 25 12 15.5 45.5 76.3 20 40 17.9 20.4 13 22 50 50 HL2
AN17-M16 -20 115 130 Yes 1 black partial Yes tin plating M16 70 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 27 13.5 16.5 46.5 78.8 20 40 17.9 20.4 13 22 25 50 HL2
AN19-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 25 7 8 43.5 71 22.5 43.5 18 20.5 13.5 25 25 25 HL2
AN19-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 25 8 9 44.5 73 22.5 43.5 18 20.5 13.5 25 25 50 HL2
AN19-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 25 10 11 46.5 77 22.5 43.5 18 20.5 13.5 25 25 50 Yes HL2
AN19-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 25 12 14 49.5 82 22.5 43.5 18 20.5 13.5 25 25 50 HL2
AN19-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 15 25 14 16 51.5 86 22.5 43.5 18 20.5 13.5 25 25 25 HL2
AN19-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 17 27 16 18 53.5 90 22.5 43.5 18 20.5 13.5 25 25 50 HL2
AN19-M20 -20 115 130 Yes 1 blue partial Yes tin plating M20 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 21 29.5 20 22 57.5 98 22.5 43.5 18 20.5 13.5 25 25 25 HL2
IN19-M6 -20 115 130 Yes 1 red partial Yes tin plating M6 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 6.4 25 7 8 43.5 76 22.5 48.5 24.3 26.7 13.5 25 25 25 HL2
IN19-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 25 8 9 44.5 78 22.5 48.5 24.3 26.7 13.5 25 25 50 Yes HL2
IN19-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 25 10 11 46.5 82 22.5 48.5 24.3 26.7 13.5 25 25 50 Yes HL2
IN19-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 25 12 14 49.5 87 22.5 48.5 24.3 26.7 13.5 25 25 50 Yes HL2
IN19-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 15 25 14 16 51.5 91 22.5 48.5 24.3 26.7 13.5 25 25 50 HL2
IN19-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes 17 27 16 18 53.5 95 22.5 48.5 24.3 26.7 13.5 25 25 50 Yes HL2
EN19-M6 -20 115 130 Yes 1 blue partial Yes tin plating M6 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 6.4 25 7 8 43.5 72.6 22.5 45 19.6 22.2 13.5 25 25 25 HL2
EN19-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 25 8 9 44.5 74.6 22.5 45 19.6 22.2 13.5 25 25 25 HL2
EN19-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 25 10 11 46.5 78.6 22.5 45 19.6 22.2 13.5 25 25 50 Yes HL2
EN19-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 25 12 14 49.5 83.6 22.5 45 19.6 22.2 13.5 25 25 50 HL2
EN19-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 25 14 16 51.5 87.6 22.5 45 19.6 22.2 13.5 25 25 50 HL2
EN19-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 27 16 18 53.5 91.6 22.5 45 19.6 22.2 13.5 25 25 50 HL2
EN19-M20 -20 115 130 Yes 1 blue partial Yes tin plating M20 70 95 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 21 29.5 20 22 57.5 99.6 22.5 45 19.6 22.2 13.5 25 25 25 HL2
AN24-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 28.5 8 9 46 73.7 24 42.7 20.1 22.7 15.2 27 25 50 Yes HL2
AN24-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 28.5 10 11 48 77.7 24 42.7 20.1 22.7 15.2 27 25 50 Yes HL2
AN24-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 28.5 12 14 51 82.7 24 42.7 20.1 22.7 15.2 27 25 50 HL2
AN24-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 15 28.5 14 16 53 86.7 24 42.7 20.1 22.7 15.2 27 25 50 HL2
AN24-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 17 28.5 16 18 55 90.7 24 42.7 20.1 22.7 15.2 27 25 50 HL2
AN24-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 21 30 20 22 59 98.7 24 42.7 20.1 22.7 15.2 27 25 25 HL2
IN24-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 28.5 8 9 46 77.5 24 46.7 22.2 24.7 15.2 27 25 50 HL2
IN24-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 28.5 10 11 48 81.5 24 46.7 22.2 24.7 15.2 27 25 50 HL2
IN24-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 28.5 12 14 51 86.5 24 46.7 22.2 24.7 15.2 27 25 50 HL2
IN24-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 15 28.5 14 16 53 90.5 24 46.7 22.2 24.7 15.2 27 25 25 HL2
IN24-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 17 28.5 16 18 55 94.5 24 46.7 22.2 24.7 15.2 27 15 15 HL2
IN24-M20 -20 115 130 Yes 1 blue partial Yes tin plating M20 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes 21 30 20 22 59 102.5 24 46.7 22.2 24.7 15.2 27 15 15 HL2
EN24-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 28.5 8 9 46 82 24 51.1 27.1 29.7 15.2 27 15 30 HL2
EN24-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 28.5 10 11 48 86 24 51.1 27.1 29.7 15.2 27 15 30 Yes HL2
EN24-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 28.5 12 14 51 91 24 51.1 27.1 29.7 15.2 27 15 30 Yes HL2
EN24-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 28.5 14 16 53 95 24 51.1 27.1 29.7 15.2 27 15 30 HL2
EN24-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 28.5 16 18 55 99 24 51.1 27.1 29.7 15.2 27 15 30 Yes HL2
EN24-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 95 120 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 21 30 20 22 59 107 24 51.1 27.1 29.7 15.2 27 15 15 HL2
IN30-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 31.5 11 13 58 104.2 26.5 62 29 32.7 16.7 30 15 30 HL2
IN30-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 31.5 11 13 58 104.2 26.5 62 29 32.7 16.7 30 15 30 HL2
IN30-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 31.5 14 16 61 110.2 26.5 62 29 32.7 16.7 30 15 30 HL2
IN30-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 15 31.5 16 18 63 114.2 26.5 62 29 32.7 16.7 30 15 30 HL2
IN30-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 17 31.5 17 19 64 116.2 26.5 62 29 32.7 16.7 30 10 20 HL2
IN30-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 21 31.5 20 22 67 122.2 26.5 62 29 32.7 16.7 30 15 15 HL2
AN30-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 31.5 11 13 58 95 26.5 52.2 23 26.6 16.7 30 15 15 Yes HL2
AN30-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 31.5 11 13 58 95 26.5 52.2 23 26.6 16.7 30 15 30 HL2
AN30-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 31.5 14 16 61 101 26.5 52.2 23 26.6 16.7 30 15 30 HL2
AN30-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 15 31.5 16 18 63 105 26.5 52.2 23 26.6 16.7 30 15 30 HL2
AN30-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 17 31.5 17 19 64 107 26.5 52.2 23 26.6 16.7 30 15 30 HL2
AN30-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes 21 31.5 20 22 67 113 26.5 52.2 23 26.6 16.7 30 15 15 HL2
EN30-M8 -20 115 130 Yes 1 blue partial Yes tin plating M8 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 8.4 31.5 11 13 58 93.5 26.5 51.1 24.5 28 16.7 30 15 15 HL2
EN30-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 31.5 11 13 58 93.5 26.5 51.1 24.5 28 16.7 30 15 30 HL2
EN30-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 31.5 14 16 61 99.5 26.5 51.1 24.5 28 16.7 30 15 30 HL2
EN30-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 31.5 16 18 63 103.5 26.5 51.1 24.5 28 16.7 30 15 15 HL2
EN30-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 31.5 17 19 64 105.5 26.5 51.1 24.5 28 16.7 30 15 15 HL2
EN30-M20 -20 115 130 Yes 1 blue partial Yes tin plating M20 120 150 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 21 31.5 20 22 67 111.5 26.5 51.1 24.5 28 16.7 30 15 15 HL2
INR37-M10 -20 115 130 Yes 1 blue partial Yes tin plating M10 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 35.5 11 13 65 110 29 64 29 33 19.2 32 10 10 Yes HL2
INR37-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 35.5 14 16 68 116 29 64 29 33 19.2 32 10 10 HL2
INR37-M14 -20 115 130 Yes 1 blue partial Yes tin plating M14 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 15 35.5 16 18 70 120 29 64 29 33 19.2 32 10 10 HL2
INR37-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 17 35.5 17 19 71 122 29 64 29 33 19.2 32 10 10 HL2
INR37-M20 -20 115 130 Yes 1 blue partial Yes tin plating M20 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 21 35.5 20 22 74 128 29 64 29 33 19.2 32 10 10 HL2
IN37-M8 -20 115 130 Yes 1 red partial Yes tin plating M8 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 8.4 35.5 11 13 65 111.5 29 65 31.6 35.3 19.2 32 10 20 HL2
IN37-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 35.5 11 13 65 111.5 29 65 31.6 35.3 19.2 32 10 20 HL2
IN37-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 35.5 14 16 68 117.5 29 65 31.6 35.3 19.2 32 10 20 HL2
IN37-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 15 35.5 16 18 70 121.5 29 65 31.6 35.3 19.2 32 10 20 HL2
IN37-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 17 35.5 17 19 71 123.5 29 65 31.6 35.3 19.2 32 10 20 HL2
IN37-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 150 185 Electrolitic copper with purity above 99.95% Polyamide Yes 21 35.5 20 22 74 129.5 29 65 31.6 35.3 19.2 32 10 10 HL2
IN48-M8 1 1
IN48-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 185 Electrolitic copper with purity above 99.95% Polyamide Yes 10.5 39 11 13 66.5 114.5 36 70.3 34.5 38.3 21.1 40 10 10 HL2
IN48-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 185 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 39 12 14 67.5 116.5 36 70.3 34.5 38.3 21.1 40 10 20 HL2
IN48-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 185 Electrolitic copper with purity above 99.95% Polyamide Yes 15 39 16 18 76 129 33 70.3 34.5 38.3 21.1 37 10 10 Yes HL2
IN48-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 185 Electrolitic copper with purity above 99.95% Polyamide Yes 17 39 17 19 77 131 33 70.3 34.5 38.3 21.1 37 10 20 Yes HL2
IN48-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 185 Electrolitic copper with purity above 99.95% Polyamide Yes 21 39 20 22 80 137 33 70.3 34.5 38.3 21.1 37 10 10 HL2
EN48-M10 -20 115 130 Yes 1 red partial Yes tin plating M10 185 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 10.5 39 11 13 66.5 105.5 36 61.2 29.4 33 21.1 40 10 20 Yes HL2
EN48-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 185 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 39 12 14 67.5 107.5 36 61.2 29.4 33 21.1 40 10 20 Yes HL2
EN48-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 185 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 39 16 18 76 120 33 61.2 29.4 33 21.1 37 10 20 HL2
EN48-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 185 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 39 17 19 77 122 33 61.2 29.4 33 21.1 37 10 20 HL2
EN48-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 185 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 21 39 20 22 80 128 33 61.2 29.4 33 21.1 37 10 20 HL2
IN60-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 240 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 44 14 20 85 142 40 82.2 38 41.5 23.7 44 5 10 HL2
IN60-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 240 Electrolitic copper with purity above 99.95% Polyamide Yes 15 44 16 22 87 146 40 82.2 38 41.5 23.7 44 5 10 Yes HL2
IN60-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 240 Electrolitic copper with purity above 99.95% Polyamide Yes 17 44 19 22 87 149 40 82.2 38 41.5 23.7 44 5 10 HL2
IN60-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 240 Electrolitic copper with purity above 99.95% Polyamide Yes 21 44 23 24 89 155 40 82.2 38 41.5 23.7 44 5 10 HL2
EN60-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 240 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 44 14 20 85 131.5 40 71.5 33.5 37.1 23.7 44 5 10 Yes HL2
EN60-M14 -20 115 130 Yes 1 red partial Yes tin plating M14 240 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 15 44 16 22 87 135.5 40 71.5 33.5 37.1 23.7 44 5 10 Yes HL2
EN60-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 240 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 44 19 22 87 138.5 40 71.5 33.5 37.1 23.7 44 5 10 HL2
EN60-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 240 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 21 44 23 24 89 144.5 40 71.5 33.5 37.1 23.7 44 5 5 HL2
EN80-M12 -20 115 130 Yes 1 blue partial Yes tin plating M12 300 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 13.2 51 19 22 94 162.7 42 90.3 37.7 41.5 27 47 5 10 Yes HL2
EN80-M16 -20 115 130 Yes 1 blue partial Yes tin plating M16 300 Electrolitic copper with purity above 99.95% Polyamide Yes Yes 17 51 19 22 94 162.7 42 90.3 37.7 41.5 27 47 5 10 HL2
IN80-M12 -20 115 130 Yes 1 red partial Yes tin plating M12 300 Electrolitic copper with purity above 99.95% Polyamide Yes 13.2 51 19 22 94 163 42 90.8 41.1 45.4 27 47 5 5 HL2
IN80-M16 -20 115 130 Yes 1 red partial Yes tin plating M16 300 Electrolitic copper with purity above 99.95% Polyamide Yes 17 51 19 22 94 163 42 90.8 41.1 45.4 27 47 5 5 HL2
IN80-M20 -20 115 130 Yes 1 red partial Yes tin plating M20 300 Electrolitic copper with purity above 99.95% Polyamide Yes 21 51 23 24 96 169 42 90.8 41.1 45.4 27 47 5 5 HL2
EN06-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 3.2
B [mm] 6
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 27
A [mm] 6
C [mm] 16
Ø2 [mm] 6.9
Ø3 [mm] 8.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN06-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 7.5
N [mm] 4
M [mm] 5
I [mm] 14
L [mm] 28
A [mm] 6
C [mm] 16
Ø2 [mm] 6.9
Ø3 [mm] 8.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN06-M3.5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3.5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 3.7
B [mm] 6.5
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 27
A [mm] 6
C [mm] 16
Ø2 [mm] 6.9
Ø3 [mm] 8.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN06-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 8.5
N [mm] 4.5
M [mm] 5.5
I [mm] 14.5
L [mm] 29
A [mm] 6
C [mm] 16
Ø2 [mm] 6.9
Ø3 [mm] 8.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN06-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 9
N [mm] 5
M [mm] 6
I [mm] 15
L [mm] 30
A [mm] 6
C [mm] 16
Ø2 [mm] 6.9
Ø3 [mm] 8.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN06-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 12
N [mm] 8
M [mm] 9
I [mm] 18
L [mm] 36
A [mm] 6
C [mm] 16
Ø2 [mm] 6.9
Ø3 [mm] 8.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN06-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour green
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.2
B [mm] 6
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 25.1
A [mm] 6
C [mm] 15.1
Ø2 [mm] 5.3
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN06-M3.5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour green
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3.5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.7
B [mm] 6.5
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 26.1
A [mm] 6
C [mm] 15.1
Ø2 [mm] 5.3
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN06-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour green
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 7.5
N [mm] 4
M [mm] 5
I [mm] 14
L [mm] 26.1
A [mm] 6
C [mm] 15.1
Ø2 [mm] 5.3
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN06-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour green
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 8.5
N [mm] 4.5
M [mm] 5.5
I [mm] 14.5
L [mm] 27.1
A [mm] 6
C [mm] 15.1
Ø2 [mm] 5.3
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN06-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour green
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 9
N [mm] 5
M [mm] 6
I [mm] 15
L [mm] 28.1
A [mm] 6
C [mm] 15.1
Ø2 [mm] 5.3
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN06-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour green
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 12
N [mm] 8
M [mm] 9
I [mm] 18
L [mm] 34.1
A [mm] 6
C [mm] 15.1
Ø2 [mm] 5.3
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN06-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.2
B [mm] 6
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 23.8
A [mm] 6
C [mm] 12.8
Ø2 [mm] 4.1
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 3000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN06-M3.5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3.5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.7
B [mm] 6.5
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 23.8
A [mm] 6
C [mm] 12.8
Ø2 [mm] 4.1
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 3000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN06-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 7.5
N [mm] 4
M [mm] 5
I [mm] 14
L [mm] 24.8
A [mm] 6
C [mm] 12.8
Ø2 [mm] 4.1
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN06-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 8.5
N [mm] 4.5
M [mm] 5.5
I [mm] 14.5
L [mm] 25.8
A [mm] 6
C [mm] 12.8
Ø2 [mm] 4.1
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 3000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN06-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 9
N [mm] 5
M [mm] 6
I [mm] 15
L [mm] 26.8
A [mm] 6
C [mm] 12.8
Ø2 [mm] 4.1
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 3000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN06-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 12
N [mm] 8
M [mm] 9
I [mm] 18
L [mm] 32.8
A [mm] 6
C [mm] 12.8
Ø2 [mm] 4.1
Ø3 [mm] 5.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR06-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 3.2
B [mm] 6
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 26
A [mm] 6
C [mm] 16.1
Ø2 [mm] 6
Ø3 [mm] 7.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR06-M3.5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3.5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 3.7
B [mm] 6.5
N [mm] 3.5
M [mm] 4.5
I [mm] 13.5
L [mm] 27.1
A [mm] 6
C [mm] 16.1
Ø2 [mm] 6
Ø3 [mm] 7.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR06-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 7.5
N [mm] 4
M [mm] 5
I [mm] 14
L [mm] 28.1
A [mm] 6
C [mm] 16.1
Ø2 [mm] 6
Ø3 [mm] 7.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR06-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 8.5
N [mm] 4.5
M [mm] 5.5
I [mm] 14.5
L [mm] 28
A [mm] 6
C [mm] 16.1
Ø2 [mm] 6
Ø3 [mm] 7.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 2000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR06-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 9
N [mm] 5
M [mm] 6
I [mm] 15
L [mm] 29
A [mm] 6
C [mm] 16.1
Ø2 [mm] 6
Ø3 [mm] 7.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR06-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 1.5 - 2.5
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 12
N [mm] 8
M [mm] 9
I [mm] 18
L [mm] 35
A [mm] 6
C [mm] 16.1
Ø2 [mm] 6
Ø3 [mm] 7.5
Ø [mm] 2.4
Cable stripping length [mm] 7
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN1-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.2
B [mm] 7.5
N [mm] 3.5
M [mm] 4.5
I [mm] 17
L [mm] 30.6
A [mm] 8
C [mm] 18.1
Ø2 [mm] 6.6
Ø3 [mm] 8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1500
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN1-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 8
N [mm] 4
M [mm] 5
I [mm] 17.5
L [mm] 31.6
A [mm] 8
C [mm] 18.1
Ø2 [mm] 6.6
Ø3 [mm] 8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN1-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 9
N [mm] 6
M [mm] 6.5
I [mm] 19
L [mm] 35.1
A [mm] 8
C [mm] 18.1
Ø2 [mm] 6.6
Ø3 [mm] 8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN1-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 19.5
L [mm] 35.6
A [mm] 8
C [mm] 18.1
Ø2 [mm] 6.6
Ø3 [mm] 8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN1-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 14
N [mm] 8
M [mm] 9
I [mm] 21.5
L [mm] 39.6
A [mm] 8
C [mm] 18.1
Ø2 [mm] 6.6
Ø3 [mm] 8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN1-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 16.5
N [mm] 10
M [mm] 11
I [mm] 24
L [mm] 44.1
A [mm] 8
C [mm] 18.1
Ø2 [mm] 6.6
Ø3 [mm] 8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN1-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.2
B [mm] 7.5
N [mm] 3.5
M [mm] 4.5
I [mm] 17
L [mm] 27.5
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN1-M3.5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3.5
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.7
B [mm] 7.5
N [mm] 3.5
M [mm] 4.5
I [mm] 17
L [mm] 27.5
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN1-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 8
N [mm] 4
M [mm] 5
I [mm] 17.5
L [mm] 28.5
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN1-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 9
N [mm] 6
M [mm] 6.5
I [mm] 19
L [mm] 32
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN1-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 19.5
L [mm] 32.5
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN1-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 14
N [mm] 8
M [mm] 9
I [mm] 21.5
L [mm] 36.5
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN1-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 16.5
N [mm] 10
M [mm] 11
I [mm] 24
L [mm] 41
A [mm] 8
C [mm] 15
Ø2 [mm] 5.3
Ø3 [mm] 6.8
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN1-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 3.2
B [mm] 7.5
N [mm] 3.5
M [mm] 4.5
I [mm] 17
L [mm] 35.8
A [mm] 8
C [mm] 23.3
Ø2 [mm] 14.1
Ø3 [mm] 15.5
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN1-M3.5
Minimum operating temperature [°c] –
Maximum operating temperature [°c] –
Threshold of operating temperature for short periods [°c] –
Spy hole –
Number of holes on the palm –
Insulated cover colour –
Type of insulation –
Easy insertion input –
Surface treatment –
Screw pitch –
Range of cable cross section (flexible) [mm²] –
Range of cable cross section (low stranded) [mm²] –
Conductor body material –
Insulated cover material –
Annealing –
Halogen free –
ØD [mm] –
B [mm] –
N [mm] –
M [mm] –
I [mm] –
L [mm] –
A [mm] –
C [mm] –
Ø2 [mm] –
Ø3 [mm] –
Ø [mm] –
Cable stripping length [mm] –
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) –
EN1-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 8
N [mm] 4
M [mm] 5
I [mm] 17.5
L [mm] 36.8
A [mm] 8
C [mm] 23.3
Ø2 [mm] 14.1
Ø3 [mm] 15.5
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN1-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 9
N [mm] 6
M [mm] 6.5
I [mm] 19
L [mm] 40.3
A [mm] 8
C [mm] 23.3
Ø2 [mm] 14.1
Ø3 [mm] 15.5
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN1-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 19.5
L [mm] 40.8
A [mm] 8
C [mm] 23.3
Ø2 [mm] 14.1
Ø3 [mm] 15.5
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN1-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 14
N [mm] 8
M [mm] 9
I [mm] 21.5
L [mm] 44.8
A [mm] 8
C [mm] 23.3
Ø2 [mm] 14.1
Ø3 [mm] 15.5
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN1-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 16.5
N [mm] 10
M [mm] 11
I [mm] 24
L [mm] 49.3
A [mm] 8
C [mm] 23.3
Ø2 [mm] 14.1
Ø3 [mm] 15.5
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ON1-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 3.2
B [mm] 7.5
N [mm] 3.5
M [mm] 4.5
I [mm] 17
L [mm] 32.5
A [mm] 8
C [mm] 20
Ø2 [mm] 7.6
Ø3 [mm] 9
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant –
EN 45545-2 certification (r22) HL2
ON1-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 8
N [mm] 4
M [mm] 5
I [mm] 17.5
L [mm] 33.5
A [mm] 8
C [mm] 20
Ø2 [mm] 7.6
Ø3 [mm] 9
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ON1-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 9
N [mm] 6
M [mm] 6.5
I [mm] 19
L [mm] 37
A [mm] 8
C [mm] 20
Ø2 [mm] 7.6
Ø3 [mm] 9
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ON1-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 19.5
L [mm] 37.5
A [mm] 8
C [mm] 20
Ø2 [mm] 7.6
Ø3 [mm] 9
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ON1-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 14
N [mm] 8
M [mm] 9
I [mm] 21.5
L [mm] 41.5
A [mm] 8
C [mm] 20
Ø2 [mm] 7.6
Ø3 [mm] 9
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ON1-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 16.5
N [mm] 10
M [mm] 11
I [mm] 24
L [mm] 46
A [mm] 8
C [mm] 20
Ø2 [mm] 7.6
Ø3 [mm] 9
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
UN1-M3
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M3
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 3.2
B [mm] 7.5
N [mm] 3.5
M [mm] 4.5
I [mm] 17
L [mm] 32.1
A [mm] 8
C [mm] 19.6
Ø2 [mm] 8.7
Ø3 [mm] 10
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant –
EN 45545-2 certification (r22) HL2
UN1-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 8
N [mm] 4
M [mm] 5
I [mm] 17.5
L [mm] 33.1
A [mm] 8
C [mm] 19.6
Ø2 [mm] 8.7
Ø3 [mm] 10
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
UN1-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 9
N [mm] 6
M [mm] 6.5
I [mm] 19
L [mm] 36.6
A [mm] 8
C [mm] 19.6
Ø2 [mm] 8.7
Ø3 [mm] 10
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
UN1-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 19.5
L [mm] 37.1
A [mm] 8
C [mm] 19.6
Ø2 [mm] 8.7
Ø3 [mm] 10
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
UN1-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 14
N [mm] 8
M [mm] 9
I [mm] 21.5
L [mm] 41.4
A [mm] 8
C [mm] 19.6
Ø2 [mm] 8.7
Ø3 [mm] 10
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
UN1-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 4 - 6
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 16.5
N [mm] 10
M [mm] 11
I [mm] 24
L [mm] 45.6
A [mm] 8
C [mm] 19.6
Ø2 [mm] 8.7
Ø3 [mm] 10
Ø [mm] 3.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN2-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 10
N [mm] 4
M [mm] 5
I [mm] 18.5
L [mm] 38
A [mm] 8
C [mm] 23.8
Ø2 [mm] 10.8
Ø3 [mm] 12
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN2-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 10
N [mm] 6
M [mm] 6.5
I [mm] 20
L [mm] 41.5
A [mm] 8
C [mm] 23.8
Ø2 [mm] 10.8
Ø3 [mm] 12
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN2-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 20.5
L [mm] 42
A [mm] 8
C [mm] 23.8
Ø2 [mm] 10.8
Ø3 [mm] 12
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN2-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 22.5
L [mm] 46
A [mm] 8
C [mm] 23.8
Ø2 [mm] 10.8
Ø3 [mm] 12
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN2-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 24.5
L [mm] 50
A [mm] 8
C [mm] 23.8
Ø2 [mm] 10.8
Ø3 [mm] 12
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN2-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 19
N [mm] 12
M [mm] 14
I [mm] 27.5
L [mm] 55
A [mm] 8
C [mm] 23.8
Ø2 [mm] 10.8
Ø3 [mm] 12
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN2-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 10
N [mm] 4
M [mm] 5
I [mm] 18.5
L [mm] 34.1
A [mm] 8
C [mm] 21
Ø2 [mm] 8
Ø3 [mm] 9.5
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN2-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 10
N [mm] 6
M [mm] 6.5
I [mm] 20
L [mm] 37.6
A [mm] 8
C [mm] 21
Ø2 [mm] 8
Ø3 [mm] 9.5
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN2-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 20.5
L [mm] 38.1
A [mm] 8
C [mm] 21
Ø2 [mm] 8
Ø3 [mm] 9.5
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN2-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 22.5
L [mm] 42.1
A [mm] 8
C [mm] 21
Ø2 [mm] 8
Ø3 [mm] 9.5
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN2-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 24.5
L [mm] 46.1
A [mm] 8
C [mm] 21
Ø2 [mm] 8
Ø3 [mm] 9.5
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN2-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 19
N [mm] 12
M [mm] 14
I [mm] 27.5
L [mm] 51
A [mm] 8
C [mm] 21
Ø2 [mm] 8
Ø3 [mm] 9.5
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN2-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 10
N [mm] 4
M [mm] 5
I [mm] 18.5
L [mm] 38
A [mm] 8
C [mm] 25.1
Ø2 [mm] 15.1
Ø3 [mm] 16.7
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN2-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 10
N [mm] 6
M [mm] 6.5
I [mm] 20
L [mm] 41.5
A [mm] 8
C [mm] 25.1
Ø2 [mm] 15.1
Ø3 [mm] 16.7
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN2-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 20.5
L [mm] 42
A [mm] 8
C [mm] 25.1
Ø2 [mm] 15.1
Ø3 [mm] 16.7
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN2-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 22.5
L [mm] 46
A [mm] 8
C [mm] 25.1
Ø2 [mm] 15.1
Ø3 [mm] 16.7
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN2-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 24.5
L [mm] 50
A [mm] 8
C [mm] 25.1
Ø2 [mm] 15.1
Ø3 [mm] 16.7
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN2-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 19
N [mm] 12
M [mm] 14
I [mm] 27.5
L [mm] 55
A [mm] 8
C [mm] 25.1
Ø2 [mm] 15.1
Ø3 [mm] 16.7
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR2-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 10
N [mm] 4
M [mm] 5
I [mm] 18.5
L [mm] 39
A [mm] 8
C [mm] 26.1
Ø2 [mm] 12.5
Ø3 [mm] 14
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR2-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 10
N [mm] 6
M [mm] 6.5
I [mm] 20
L [mm] 42.5
A [mm] 8
C [mm] 26.1
Ø2 [mm] 12.5
Ø3 [mm] 14
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR2-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 11
N [mm] 6
M [mm] 7
I [mm] 20.5
L [mm] 43
A [mm] 8
C [mm] 26.1
Ø2 [mm] 12.5
Ø3 [mm] 14
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR2-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 22.5
L [mm] 47
A [mm] 8
C [mm] 26.1
Ø2 [mm] 12.5
Ø3 [mm] 14
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR2-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 24.5
L [mm] 51
A [mm] 8
C [mm] 26.1
Ø2 [mm] 12.5
Ø3 [mm] 14
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR2-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 10
Range of cable cross section (low stranded) [mm²] 10
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 19
N [mm] 12
M [mm] 14
I [mm] 27.5
L [mm] 56
A [mm] 8
C [mm] 26.1
Ø2 [mm] 12.5
Ø3 [mm] 14
Ø [mm] 4.6
Cable stripping length [mm] 9
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN3-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 11.5
N [mm] 4
M [mm] 5
I [mm] 21.5
L [mm] 38.6
A [mm] 11.5
C [mm] 24
Ø2 [mm] 9.2
Ø3 [mm] 10.5
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN3-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 11.5
N [mm] 6
M [mm] 6.5
I [mm] 23
L [mm] 42.1
A [mm] 11.5
C [mm] 24
Ø2 [mm] 9.2
Ø3 [mm] 10.5
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN3-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11.5
N [mm] 6
M [mm] 7
I [mm] 23.5
L [mm] 42.6
A [mm] 11.5
C [mm] 24
Ø2 [mm] 9.2
Ø3 [mm] 10.5
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN3-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 25.5
L [mm] 46.6
A [mm] 11.5
C [mm] 24
Ø2 [mm] 9.2
Ø3 [mm] 10.5
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN3-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 27.5
L [mm] 50.6
A [mm] 11.5
C [mm] 24
Ø2 [mm] 9.2
Ø3 [mm] 10.5
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN3-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 20
N [mm] 12
M [mm] 14
I [mm] 32
L [mm] 57.1
A [mm] 11.5
C [mm] 24
Ø2 [mm] 9.2
Ø3 [mm] 10.5
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN3-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 4.3
B [mm] 11.5
N [mm] 4
M [mm] 5
I [mm] 21.5
L [mm] 40.5
A [mm] 11.5
C [mm] 25.7
Ø2 [mm] 11.7
Ø3 [mm] 13.4
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN3-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 11.5
N [mm] 6
M [mm] 6.5
I [mm] 23
L [mm] 44
A [mm] 11.5
C [mm] 25.7
Ø2 [mm] 11.7
Ø3 [mm] 13.4
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN3-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 11.5
N [mm] 6
M [mm] 7
I [mm] 23.5
L [mm] 44.5
A [mm] 11.5
C [mm] 25.7
Ø2 [mm] 11.7
Ø3 [mm] 13.4
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN3-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 25.5
L [mm] 48.5
A [mm] 11.5
C [mm] 25.7
Ø2 [mm] 11.7
Ø3 [mm] 13.4
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN3-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 27.5
L [mm] 52.5
A [mm] 11.5
C [mm] 25.7
Ø2 [mm] 11.7
Ø3 [mm] 13.4
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN3-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 20
N [mm] 12
M [mm] 14
I [mm] 32
L [mm] 59
A [mm] 11.5
C [mm] 25.7
Ø2 [mm] 11.7
Ø3 [mm] 13.4
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN3-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 11.5
N [mm] 4
M [mm] 5
I [mm] 21.5
L [mm] 42.8
A [mm] 11.5
C [mm] 27.9
Ø2 [mm] 16.9
Ø3 [mm] 18.6
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN3-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 11.5
N [mm] 6
M [mm] 6.5
I [mm] 23
L [mm] 46.3
A [mm] 11.5
C [mm] 27.9
Ø2 [mm] 16.9
Ø3 [mm] 18.6
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN3-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 11.5
N [mm] 6
M [mm] 7
I [mm] 23.5
L [mm] 46.8
A [mm] 11.5
C [mm] 27.9
Ø2 [mm] 16.9
Ø3 [mm] 18.6
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN3-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 25.5
L [mm] 50.8
A [mm] 11.5
C [mm] 27.9
Ø2 [mm] 16.9
Ø3 [mm] 18.6
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN3-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 27.5
L [mm] 54.8
A [mm] 11.5
C [mm] 27.9
Ø2 [mm] 16.9
Ø3 [mm] 18.6
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN3-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 16
Range of cable cross section (low stranded) [mm²] 16
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 20
N [mm] 12
M [mm] 14
I [mm] 32
L [mm] 44
A [mm] 11.5
C [mm] 27.9
Ø2 [mm] 16.9
Ø3 [mm] 18.6
Ø [mm] 5.8
Cable stripping length [mm] 13
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN5-M4
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M4
Range of cable cross section (flexible) [mm²] 25
Range of cable cross section (low stranded) [mm²] 25
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 4.3
B [mm] 14
N [mm] 4
M [mm] 5
I [mm] 24
L [mm] 41
A [mm] 10.5
C [mm] 25
Ø2 [mm] 11.1
Ø3 [mm] 13
Ø [mm] 7
Cable stripping length [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN5-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 25
Range of cable cross section (low stranded) [mm²] 25
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 14
N [mm] 6
M [mm] 6.5
I [mm] 25.5
L [mm] 44.5
A [mm] 10.5
C [mm] 25
Ø2 [mm] 11.1
Ø3 [mm] 13
Ø [mm] 7
Cable stripping length [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN5-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 25
Range of cable cross section (low stranded) [mm²] 25
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 14
N [mm] 6
M [mm] 7
I [mm] 26
L [mm] 45
A [mm] 10.5
C [mm] 25
Ø2 [mm] 11.1
Ø3 [mm] 13
Ø [mm] 7
Cable stripping length [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN5-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 25
Range of cable cross section (low stranded) [mm²] 25
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 15
N [mm] 8
M [mm] 9
I [mm] 28
L [mm] 49
A [mm] 10.5
C [mm] 25
Ø2 [mm] 11.1
Ø3 [mm] 13
Ø [mm] 7
Cable stripping length [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN5-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 25
Range of cable cross section (low stranded) [mm²] 25
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 18
N [mm] 10
M [mm] 11
I [mm] 30
L [mm] 53
A [mm] 10.5
C [mm] 25
Ø2 [mm] 11.1
Ø3 [mm] 13
Ø [mm] 7
Cable stripping length [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN5-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour yellow
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 25
Range of cable cross section (low stranded) [mm²] 25
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 14
I [mm] 33
L [mm] 58
A [mm] 10.5
C [mm] 25
Ø2 [mm] 11.1
Ø3 [mm] 13
Ø [mm] 7
Cable stripping length [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 300
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN7-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 17
N [mm] 6
M [mm] 6.5
I [mm] 28
L [mm] 47.5
A [mm] 13.2
C [mm] 27.5
Ø2 [mm] 11.9
Ø3 [mm] 14
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN7-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 17
N [mm] 6
M [mm] 7
I [mm] 28.5
L [mm] 48
A [mm] 13.2
C [mm] 27.5
Ø2 [mm] 11.9
Ø3 [mm] 14
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN7-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 17
N [mm] 8
M [mm] 9
I [mm] 30.5
L [mm] 52
A [mm] 13.2
C [mm] 27.5
Ø2 [mm] 11.9
Ø3 [mm] 14
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN7-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 19
N [mm] 10
M [mm] 11
I [mm] 32.5
L [mm] 56
A [mm] 13.2
C [mm] 27.5
Ø2 [mm] 11.9
Ø3 [mm] 14
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN7-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 14
I [mm] 35.5
L [mm] 61
A [mm] 13.2
C [mm] 27.5
Ø2 [mm] 11.9
Ø3 [mm] 14
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN7-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 5.3
B [mm] 17
N [mm] 6
M [mm] 6.5
I [mm] 28
L [mm] 56.2
A [mm] 13.2
C [mm] 36.1
Ø2 [mm] 18.7
Ø3 [mm] 20.5
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 150
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN7-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 17
N [mm] 6
M [mm] 7
I [mm] 28.5
L [mm] 56.7
A [mm] 13.2
C [mm] 36.1
Ø2 [mm] 18.7
Ø3 [mm] 20.5
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 150
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN7-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 17
N [mm] 8
M [mm] 9
I [mm] 30.5
L [mm] 60.7
A [mm] 13.2
C [mm] 36.1
Ø2 [mm] 18.7
Ø3 [mm] 20.5
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 150
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN7-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 19
N [mm] 10
M [mm] 11
I [mm] 32.5
L [mm] 64.7
A [mm] 13.2
C [mm] 36.1
Ø2 [mm] 18.7
Ø3 [mm] 20.5
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN7-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 14
I [mm] 35.5
L [mm] 69.7
A [mm] 13.2
C [mm] 36.1
Ø2 [mm] 18.7
Ø3 [mm] 20.5
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN7-M5
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M5
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 5.3
B [mm] 17
N [mm] 6
M [mm] 6.5
I [mm] 28
L [mm] 46.7
A [mm] 13.2
C [mm] 26.5
Ø2 [mm] 13
Ø3 [mm] 15
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN7-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 17
N [mm] 6
M [mm] 7
I [mm] 28.5
L [mm] 47.2
A [mm] 13.2
C [mm] 26.5
Ø2 [mm] 13
Ø3 [mm] 15
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN7-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 17
N [mm] 8
M [mm] 9
I [mm] 30.5
L [mm] 51.2
A [mm] 13.2
C [mm] 26.5
Ø2 [mm] 13
Ø3 [mm] 15
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN7-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 19
N [mm] 10
M [mm] 11
I [mm] 32.5
L [mm] 55.2
A [mm] 13.2
C [mm] 26.5
Ø2 [mm] 13
Ø3 [mm] 15
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN7-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 25 - 35
Range of cable cross section (low stranded) [mm²] 35
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 14
I [mm] 35.5
L [mm] 60.2
A [mm] 13.2
C [mm] 26.5
Ø2 [mm] 13
Ø3 [mm] 15
Ø [mm] 8.9
Cable stripping length [mm] 15
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN10-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 19
N [mm] 7
M [mm] 8
I [mm] 31.5
L [mm] 53
A [mm] 16.5
C [mm] 30.5
Ø2 [mm] 13.8
Ø3 [mm] 15.8
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN10-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 19
N [mm] 8
M [mm] 9
I [mm] 32.5
L [mm] 55
A [mm] 16.5
C [mm] 30.5
Ø2 [mm] 13.8
Ø3 [mm] 15.8
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 200
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN10-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 20
N [mm] 9.5
M [mm] 11.5
I [mm] 35
L [mm] 59
A [mm] 16.5
C [mm] 30.5
Ø2 [mm] 13.8
Ø3 [mm] 15.8
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 200
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN10-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 12
I [mm] 35.5
L [mm] 62
A [mm] 16.5
C [mm] 30.5
Ø2 [mm] 13.8
Ø3 [mm] 15.8
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 150
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN10-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 41.5
L [mm] 70
A [mm] 16.5
C [mm] 30.5
Ø2 [mm] 13.8
Ø3 [mm] 15.8
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN10-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour transparent
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 43.5
L [mm] 74
A [mm] 16.5
C [mm] 30.5
Ø2 [mm] 13.8
Ø3 [mm] 15.8
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN10-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 19
N [mm] 7
M [mm] 8
I [mm] 31.5
L [mm] 54.3
A [mm] 16.5
C [mm] 33.8
Ø2 [mm] 15
Ø3 [mm] 17
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN10-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 19
N [mm] 8
M [mm] 9
I [mm] 32.5
L [mm] 56.3
A [mm] 16.5
C [mm] 33.8
Ø2 [mm] 15
Ø3 [mm] 17
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN10-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 20
N [mm] 9.5
M [mm] 11.5
I [mm] 35
L [mm] 60.3
A [mm] 16.5
C [mm] 33.8
Ø2 [mm] 15
Ø3 [mm] 17
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 150
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN10-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 12
I [mm] 35.5
L [mm] 63.3
A [mm] 16.5
C [mm] 33.8
Ø2 [mm] 15
Ø3 [mm] 17
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN10-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 41.5
L [mm] 71.3
A [mm] 16.5
C [mm] 33.8
Ø2 [mm] 15
Ø3 [mm] 17
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN10-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 43.5
L [mm] 75.3
A [mm] 16.5
C [mm] 33.8
Ø2 [mm] 15
Ø3 [mm] 17
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR10-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 19
N [mm] 7
M [mm] 8
I [mm] 31.5
L [mm] 57.5
A [mm] 16.5
C [mm] 37
Ø2 [mm] 17.3
Ø3 [mm] 19
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR10-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 19
N [mm] 8
M [mm] 9
I [mm] 32.5
L [mm] 59.5
A [mm] 16.5
C [mm] 37
Ø2 [mm] 17.3
Ø3 [mm] 19
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR10-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 20
N [mm] 9.5
M [mm] 11.5
I [mm] 35
L [mm] 63.5
A [mm] 16.5
C [mm] 37
Ø2 [mm] 17.3
Ø3 [mm] 19
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
ENR10-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 12
I [mm] 35.5
L [mm] 66.5
A [mm] 16.5
C [mm] 37
Ø2 [mm] 17.3
Ø3 [mm] 19
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR10-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 41.5
L [mm] 74.5
A [mm] 16.5
C [mm] 37
Ø2 [mm] 17.3
Ø3 [mm] 19
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
ENR10-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 43.5
L [mm] 78.5
A [mm] 16.5
C [mm] 37
Ø2 [mm] 17.3
Ø3 [mm] 19
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN10-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 19
N [mm] 7
M [mm] 8
I [mm] 31.5
L [mm] 60.5
A [mm] 16.5
C [mm] 40
Ø2 [mm] 20.2
Ø3 [mm] 22
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN10-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 19
N [mm] 8
M [mm] 9
I [mm] 32.5
L [mm] 62.5
A [mm] 16.5
C [mm] 40
Ø2 [mm] 20.2
Ø3 [mm] 22
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN10-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 20
N [mm] 9.5
M [mm] 11.5
I [mm] 35
L [mm] 66.5
A [mm] 16.5
C [mm] 40
Ø2 [mm] 20.2
Ø3 [mm] 22
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN10-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 21
N [mm] 12
M [mm] 12
I [mm] 35.5
L [mm] 69.5
A [mm] 16.5
C [mm] 40
Ø2 [mm] 20.2
Ø3 [mm] 22
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN10-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 41.5
L [mm] 77.5
A [mm] 16.5
C [mm] 40
Ø2 [mm] 20.2
Ø3 [mm] 22
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN10-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 35
Range of cable cross section (low stranded) [mm²] 50
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 43.5
L [mm] 81.5
A [mm] 16.5
C [mm] 40
Ø2 [mm] 20.2
Ø3 [mm] 22
Ø [mm] 10
Cable stripping length [mm] 19
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN14-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 21
N [mm] 7
M [mm] 8
I [mm] 37
L [mm] 64
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN14-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 21
N [mm] 8
M [mm] 9
I [mm] 38
L [mm] 66
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN14-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 21
N [mm] 10
M [mm] 11
I [mm] 40
L [mm] 70
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN14-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 22
N [mm] 12
M [mm] 14
I [mm] 43
L [mm] 75
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN14-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 45
L [mm] 79
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN14-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 47
L [mm] 83
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN14-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 21
N [mm] 7
M [mm] 8
I [mm] 37
L [mm] 68
A [mm] 18
C [mm] 42.9
Ø2 [mm] 21.9
Ø3 [mm] 24.3
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN14-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 21
N [mm] 8
M [mm] 9
I [mm] 38
L [mm] 70
A [mm] 18
C [mm] 42.9
Ø2 [mm] 21.9
Ø3 [mm] 24.3
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN14-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 21
N [mm] 10
M [mm] 11
I [mm] 40
L [mm] 74
A [mm] 18
C [mm] 42.9
Ø2 [mm] 21.9
Ø3 [mm] 24.3
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN14-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 22
N [mm] 12
M [mm] 14
I [mm] 43
L [mm] 79
A [mm] 18
C [mm] 42.9
Ø2 [mm] 21.9
Ø3 [mm] 24.3
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN14-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 45
L [mm] 83
A [mm] 18
C [mm] 42.9
Ø2 [mm] 21.9
Ø3 [mm] 24.3
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN14-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 47
L [mm] 87
A [mm] 18
C [mm] 42.9
Ø2 [mm] 21.9
Ø3 [mm] 24.3
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN14-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 21
N [mm] 7
M [mm] 8
I [mm] 37
L [mm] 61
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN14-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 21
N [mm] 8
M [mm] 9
I [mm] 38
L [mm] 63
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN14-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 21
N [mm] 10
M [mm] 11
I [mm] 40
L [mm] 67
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN14-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 22
N [mm] 12
M [mm] 14
I [mm] 43
L [mm] 72
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN14-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 45
L [mm] 76
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN14-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 50
Range of cable cross section (low stranded) [mm²] 70
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 26
N [mm] 16
M [mm] 18
I [mm] 47
L [mm] 80
A [mm] 18
C [mm] 39
Ø2 [mm] 16.9
Ø3 [mm] 19.2
Ø [mm] 11.3
Cable stripping length [mm] 20
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN17-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour black
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 23
N [mm] 8
M [mm] 9
I [mm] 39
L [mm] 65.8
A [mm] 20
C [mm] 40
Ø2 [mm] 17.9
Ø3 [mm] 20.4
Ø [mm] 13
Cable stripping length [mm] 22
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN17-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour black
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 23
N [mm] 10
M [mm] 11
I [mm] 41
L [mm] 69.8
A [mm] 20
C [mm] 40
Ø2 [mm] 17.9
Ø3 [mm] 20.4
Ø [mm] 13
Cable stripping length [mm] 22
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 100
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN17-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour black
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 23
N [mm] 12
M [mm] 14
I [mm] 44
L [mm] 74.8
A [mm] 20
C [mm] 40
Ø2 [mm] 17.9
Ø3 [mm] 20.4
Ø [mm] 13
Cable stripping length [mm] 22
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN17-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour black
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 25
N [mm] 12
M [mm] 15.5
I [mm] 45.5
L [mm] 76.3
A [mm] 20
C [mm] 40
Ø2 [mm] 17.9
Ø3 [mm] 20.4
Ø [mm] 13
Cable stripping length [mm] 22
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN17-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour black
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 27
N [mm] 13.5
M [mm] 16.5
I [mm] 46.5
L [mm] 78.8
A [mm] 20
C [mm] 40
Ø2 [mm] 17.9
Ø3 [mm] 20.4
Ø [mm] 13
Cable stripping length [mm] 22
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN19-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 25
N [mm] 7
M [mm] 8
I [mm] 43.5
L [mm] 71
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN19-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 25
N [mm] 8
M [mm] 9
I [mm] 44.5
L [mm] 73
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN19-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 25
N [mm] 10
M [mm] 11
I [mm] 46.5
L [mm] 77
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN19-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 25
N [mm] 12
M [mm] 14
I [mm] 49.5
L [mm] 82
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN19-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 51.5
L [mm] 86
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN19-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 27
N [mm] 16
M [mm] 18
I [mm] 53.5
L [mm] 90
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN19-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 29.5
N [mm] 20
M [mm] 22
I [mm] 57.5
L [mm] 98
A [mm] 22.5
C [mm] 43.5
Ø2 [mm] 18
Ø3 [mm] 20.5
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN19-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 6.4
B [mm] 25
N [mm] 7
M [mm] 8
I [mm] 43.5
L [mm] 76
A [mm] 22.5
C [mm] 48.5
Ø2 [mm] 24.3
Ø3 [mm] 26.7
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN19-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 25
N [mm] 8
M [mm] 9
I [mm] 44.5
L [mm] 78
A [mm] 22.5
C [mm] 48.5
Ø2 [mm] 24.3
Ø3 [mm] 26.7
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN19-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 25
N [mm] 10
M [mm] 11
I [mm] 46.5
L [mm] 82
A [mm] 22.5
C [mm] 48.5
Ø2 [mm] 24.3
Ø3 [mm] 26.7
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN19-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 25
N [mm] 12
M [mm] 14
I [mm] 49.5
L [mm] 87
A [mm] 22.5
C [mm] 48.5
Ø2 [mm] 24.3
Ø3 [mm] 26.7
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN19-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 51.5
L [mm] 91
A [mm] 22.5
C [mm] 48.5
Ø2 [mm] 24.3
Ø3 [mm] 26.7
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN19-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 27
N [mm] 16
M [mm] 18
I [mm] 53.5
L [mm] 95
A [mm] 22.5
C [mm] 48.5
Ø2 [mm] 24.3
Ø3 [mm] 26.7
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN19-M6
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M6
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 6.4
B [mm] 25
N [mm] 7
M [mm] 8
I [mm] 43.5
L [mm] 72.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN19-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 25
N [mm] 8
M [mm] 9
I [mm] 44.5
L [mm] 74.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN19-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 25
N [mm] 10
M [mm] 11
I [mm] 46.5
L [mm] 78.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN19-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 25
N [mm] 12
M [mm] 14
I [mm] 49.5
L [mm] 83.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN19-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 25
N [mm] 14
M [mm] 16
I [mm] 51.5
L [mm] 87.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN19-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 27
N [mm] 16
M [mm] 18
I [mm] 53.5
L [mm] 91.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN19-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 70
Range of cable cross section (low stranded) [mm²] 95
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 21
B [mm] 29.5
N [mm] 20
M [mm] 22
I [mm] 57.5
L [mm] 99.6
A [mm] 22.5
C [mm] 45
Ø2 [mm] 19.6
Ø3 [mm] 22.2
Ø [mm] 13.5
Cable stripping length [mm] 25
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN24-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 28.5
N [mm] 8
M [mm] 9
I [mm] 46
L [mm] 73.7
A [mm] 24
C [mm] 42.7
Ø2 [mm] 20.1
Ø3 [mm] 22.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN24-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 28.5
N [mm] 10
M [mm] 11
I [mm] 48
L [mm] 77.7
A [mm] 24
C [mm] 42.7
Ø2 [mm] 20.1
Ø3 [mm] 22.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN24-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 28.5
N [mm] 12
M [mm] 14
I [mm] 51
L [mm] 82.7
A [mm] 24
C [mm] 42.7
Ø2 [mm] 20.1
Ø3 [mm] 22.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN24-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 28.5
N [mm] 14
M [mm] 16
I [mm] 53
L [mm] 86.7
A [mm] 24
C [mm] 42.7
Ø2 [mm] 20.1
Ø3 [mm] 22.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN24-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 28.5
N [mm] 16
M [mm] 18
I [mm] 55
L [mm] 90.7
A [mm] 24
C [mm] 42.7
Ø2 [mm] 20.1
Ø3 [mm] 22.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN24-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 30
N [mm] 20
M [mm] 22
I [mm] 59
L [mm] 98.7
A [mm] 24
C [mm] 42.7
Ø2 [mm] 20.1
Ø3 [mm] 22.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN24-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 28.5
N [mm] 8
M [mm] 9
I [mm] 46
L [mm] 77.5
A [mm] 24
C [mm] 46.7
Ø2 [mm] 22.2
Ø3 [mm] 24.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN24-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 28.5
N [mm] 10
M [mm] 11
I [mm] 48
L [mm] 81.5
A [mm] 24
C [mm] 46.7
Ø2 [mm] 22.2
Ø3 [mm] 24.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN24-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 28.5
N [mm] 12
M [mm] 14
I [mm] 51
L [mm] 86.5
A [mm] 24
C [mm] 46.7
Ø2 [mm] 22.2
Ø3 [mm] 24.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN24-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 28.5
N [mm] 14
M [mm] 16
I [mm] 53
L [mm] 90.5
A [mm] 24
C [mm] 46.7
Ø2 [mm] 22.2
Ø3 [mm] 24.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 25
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN24-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 28.5
N [mm] 16
M [mm] 18
I [mm] 55
L [mm] 94.5
A [mm] 24
C [mm] 46.7
Ø2 [mm] 22.2
Ø3 [mm] 24.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN24-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 30
N [mm] 20
M [mm] 22
I [mm] 59
L [mm] 102.5
A [mm] 24
C [mm] 46.7
Ø2 [mm] 22.2
Ø3 [mm] 24.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN24-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 28.5
N [mm] 8
M [mm] 9
I [mm] 46
L [mm] 82
A [mm] 24
C [mm] 51.1
Ø2 [mm] 27.1
Ø3 [mm] 29.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN24-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 28.5
N [mm] 10
M [mm] 11
I [mm] 48
L [mm] 86
A [mm] 24
C [mm] 51.1
Ø2 [mm] 27.1
Ø3 [mm] 29.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN24-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 28.5
N [mm] 12
M [mm] 14
I [mm] 51
L [mm] 91
A [mm] 24
C [mm] 51.1
Ø2 [mm] 27.1
Ø3 [mm] 29.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN24-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 28.5
N [mm] 14
M [mm] 16
I [mm] 53
L [mm] 95
A [mm] 24
C [mm] 51.1
Ø2 [mm] 27.1
Ø3 [mm] 29.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN24-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 28.5
N [mm] 16
M [mm] 18
I [mm] 55
L [mm] 99
A [mm] 24
C [mm] 51.1
Ø2 [mm] 27.1
Ø3 [mm] 29.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN24-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 95
Range of cable cross section (low stranded) [mm²] 120
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 21
B [mm] 30
N [mm] 20
M [mm] 22
I [mm] 59
L [mm] 107
A [mm] 24
C [mm] 51.1
Ø2 [mm] 27.1
Ø3 [mm] 29.7
Ø [mm] 15.2
Cable stripping length [mm] 27
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN30-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 31.5
N [mm] 11
M [mm] 13
I [mm] 58
L [mm] 104.2
A [mm] 26.5
C [mm] 62
Ø2 [mm] 29
Ø3 [mm] 32.7
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN30-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 31.5
N [mm] 11
M [mm] 13
I [mm] 58
L [mm] 104.2
A [mm] 26.5
C [mm] 62
Ø2 [mm] 29
Ø3 [mm] 32.7
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN30-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 31.5
N [mm] 14
M [mm] 16
I [mm] 61
L [mm] 110.2
A [mm] 26.5
C [mm] 62
Ø2 [mm] 29
Ø3 [mm] 32.7
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN30-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 31.5
N [mm] 16
M [mm] 18
I [mm] 63
L [mm] 114.2
A [mm] 26.5
C [mm] 62
Ø2 [mm] 29
Ø3 [mm] 32.7
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN30-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 31.5
N [mm] 17
M [mm] 19
I [mm] 64
L [mm] 116.2
A [mm] 26.5
C [mm] 62
Ø2 [mm] 29
Ø3 [mm] 32.7
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN30-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 31.5
N [mm] 20
M [mm] 22
I [mm] 67
L [mm] 122.2
A [mm] 26.5
C [mm] 62
Ø2 [mm] 29
Ø3 [mm] 32.7
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN30-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 31.5
N [mm] 11
M [mm] 13
I [mm] 58
L [mm] 95
A [mm] 26.5
C [mm] 52.2
Ø2 [mm] 23
Ø3 [mm] 26.6
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
AN30-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 31.5
N [mm] 11
M [mm] 13
I [mm] 58
L [mm] 95
A [mm] 26.5
C [mm] 52.2
Ø2 [mm] 23
Ø3 [mm] 26.6
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN30-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 31.5
N [mm] 14
M [mm] 16
I [mm] 61
L [mm] 101
A [mm] 26.5
C [mm] 52.2
Ø2 [mm] 23
Ø3 [mm] 26.6
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN30-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 31.5
N [mm] 16
M [mm] 18
I [mm] 63
L [mm] 105
A [mm] 26.5
C [mm] 52.2
Ø2 [mm] 23
Ø3 [mm] 26.6
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN30-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 31.5
N [mm] 17
M [mm] 19
I [mm] 64
L [mm] 107
A [mm] 26.5
C [mm] 52.2
Ø2 [mm] 23
Ø3 [mm] 26.6
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
AN30-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 31.5
N [mm] 20
M [mm] 22
I [mm] 67
L [mm] 113
A [mm] 26.5
C [mm] 52.2
Ø2 [mm] 23
Ø3 [mm] 26.6
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN30-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 8.4
B [mm] 31.5
N [mm] 11
M [mm] 13
I [mm] 58
L [mm] 93.5
A [mm] 26.5
C [mm] 51.1
Ø2 [mm] 24.5
Ø3 [mm] 28
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN30-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 31.5
N [mm] 11
M [mm] 13
I [mm] 58
L [mm] 93.5
A [mm] 26.5
C [mm] 51.1
Ø2 [mm] 24.5
Ø3 [mm] 28
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN30-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 31.5
N [mm] 14
M [mm] 16
I [mm] 61
L [mm] 99.5
A [mm] 26.5
C [mm] 51.1
Ø2 [mm] 24.5
Ø3 [mm] 28
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN30-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 31.5
N [mm] 16
M [mm] 18
I [mm] 63
L [mm] 103.5
A [mm] 26.5
C [mm] 51.1
Ø2 [mm] 24.5
Ø3 [mm] 28
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN30-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 31.5
N [mm] 17
M [mm] 19
I [mm] 64
L [mm] 105.5
A [mm] 26.5
C [mm] 51.1
Ø2 [mm] 24.5
Ø3 [mm] 28
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN30-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 120
Range of cable cross section (low stranded) [mm²] 150
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 21
B [mm] 31.5
N [mm] 20
M [mm] 22
I [mm] 67
L [mm] 111.5
A [mm] 26.5
C [mm] 51.1
Ø2 [mm] 24.5
Ø3 [mm] 28
Ø [mm] 16.7
Cable stripping length [mm] 30
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 15
ROHS compliant –
EN 45545-2 certification (r22) HL2
INR37-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 35.5
N [mm] 11
M [mm] 13
I [mm] 65
L [mm] 110
A [mm] 29
C [mm] 64
Ø2 [mm] 29
Ø3 [mm] 33
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
INR37-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 35.5
N [mm] 14
M [mm] 16
I [mm] 68
L [mm] 116
A [mm] 29
C [mm] 64
Ø2 [mm] 29
Ø3 [mm] 33
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
INR37-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 35.5
N [mm] 16
M [mm] 18
I [mm] 70
L [mm] 120
A [mm] 29
C [mm] 64
Ø2 [mm] 29
Ø3 [mm] 33
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
INR37-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 35.5
N [mm] 17
M [mm] 19
I [mm] 71
L [mm] 122
A [mm] 29
C [mm] 64
Ø2 [mm] 29
Ø3 [mm] 33
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
INR37-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 35.5
N [mm] 20
M [mm] 22
I [mm] 74
L [mm] 128
A [mm] 29
C [mm] 64
Ø2 [mm] 29
Ø3 [mm] 33
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN37-M8
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M8
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 8.4
B [mm] 35.5
N [mm] 11
M [mm] 13
I [mm] 65
L [mm] 111.5
A [mm] 29
C [mm] 65
Ø2 [mm] 31.6
Ø3 [mm] 35.3
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN37-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 35.5
N [mm] 11
M [mm] 13
I [mm] 65
L [mm] 111.5
A [mm] 29
C [mm] 65
Ø2 [mm] 31.6
Ø3 [mm] 35.3
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN37-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 35.5
N [mm] 14
M [mm] 16
I [mm] 68
L [mm] 117.5
A [mm] 29
C [mm] 65
Ø2 [mm] 31.6
Ø3 [mm] 35.3
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN37-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 35.5
N [mm] 16
M [mm] 18
I [mm] 70
L [mm] 121.5
A [mm] 29
C [mm] 65
Ø2 [mm] 31.6
Ø3 [mm] 35.3
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN37-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 35.5
N [mm] 17
M [mm] 19
I [mm] 71
L [mm] 123.5
A [mm] 29
C [mm] 65
Ø2 [mm] 31.6
Ø3 [mm] 35.3
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN37-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 150
Range of cable cross section (low stranded) [mm²] 185
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 35.5
N [mm] 20
M [mm] 22
I [mm] 74
L [mm] 129.5
A [mm] 29
C [mm] 65
Ø2 [mm] 31.6
Ø3 [mm] 35.3
Ø [mm] 19.2
Cable stripping length [mm] 32
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN48-M8
Minimum operating temperature [°c] –
Maximum operating temperature [°c] –
Threshold of operating temperature for short periods [°c] –
Spy hole –
Number of holes on the palm –
Insulated cover colour –
Type of insulation –
Easy insertion input –
Surface treatment –
Screw pitch –
Range of cable cross section (flexible) [mm²] –
Range of cable cross section (low stranded) [mm²] –
Conductor body material –
Insulated cover material –
Annealing –
Halogen free –
ØD [mm] –
B [mm] –
N [mm] –
M [mm] –
I [mm] –
L [mm] –
A [mm] –
C [mm] –
Ø2 [mm] –
Ø3 [mm] –
Ø [mm] –
Cable stripping length [mm] –
Unit in minimal packaging [pce] 1
Unit in standard packaging [pce] 1
ROHS compliant –
EN 45545-2 certification (r22) –
IN48-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 10.5
B [mm] 39
N [mm] 11
M [mm] 13
I [mm] 66.5
L [mm] 114.5
A [mm] 36
C [mm] 70.3
Ø2 [mm] 34.5
Ø3 [mm] 38.3
Ø [mm] 21.1
Cable stripping length [mm] 40
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN48-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 39
N [mm] 12
M [mm] 14
I [mm] 67.5
L [mm] 116.5
A [mm] 36
C [mm] 70.3
Ø2 [mm] 34.5
Ø3 [mm] 38.3
Ø [mm] 21.1
Cable stripping length [mm] 40
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN48-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 39
N [mm] 16
M [mm] 18
I [mm] 76
L [mm] 129
A [mm] 33
C [mm] 70.3
Ø2 [mm] 34.5
Ø3 [mm] 38.3
Ø [mm] 21.1
Cable stripping length [mm] 37
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN48-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 39
N [mm] 17
M [mm] 19
I [mm] 77
L [mm] 131
A [mm] 33
C [mm] 70.3
Ø2 [mm] 34.5
Ø3 [mm] 38.3
Ø [mm] 21.1
Cable stripping length [mm] 37
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN48-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 39
N [mm] 20
M [mm] 22
I [mm] 80
L [mm] 137
A [mm] 33
C [mm] 70.3
Ø2 [mm] 34.5
Ø3 [mm] 38.3
Ø [mm] 21.1
Cable stripping length [mm] 37
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN48-M10
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M10
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 10.5
B [mm] 39
N [mm] 11
M [mm] 13
I [mm] 66.5
L [mm] 105.5
A [mm] 36
C [mm] 61.2
Ø2 [mm] 29.4
Ø3 [mm] 33
Ø [mm] 21.1
Cable stripping length [mm] 40
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN48-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 39
N [mm] 12
M [mm] 14
I [mm] 67.5
L [mm] 107.5
A [mm] 36
C [mm] 61.2
Ø2 [mm] 29.4
Ø3 [mm] 33
Ø [mm] 21.1
Cable stripping length [mm] 40
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN48-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 39
N [mm] 16
M [mm] 18
I [mm] 76
L [mm] 120
A [mm] 33
C [mm] 61.2
Ø2 [mm] 29.4
Ø3 [mm] 33
Ø [mm] 21.1
Cable stripping length [mm] 37
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN48-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 39
N [mm] 17
M [mm] 19
I [mm] 77
L [mm] 122
A [mm] 33
C [mm] 61.2
Ø2 [mm] 29.4
Ø3 [mm] 33
Ø [mm] 21.1
Cable stripping length [mm] 37
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN48-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 185
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 21
B [mm] 39
N [mm] 20
M [mm] 22
I [mm] 80
L [mm] 128
A [mm] 33
C [mm] 61.2
Ø2 [mm] 29.4
Ø3 [mm] 33
Ø [mm] 21.1
Cable stripping length [mm] 37
Unit in minimal packaging [pce] 10
Unit in standard packaging [pce] 20
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN60-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 44
N [mm] 14
M [mm] 20
I [mm] 85
L [mm] 142
A [mm] 40
C [mm] 82.2
Ø2 [mm] 38
Ø3 [mm] 41.5
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN60-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 15
B [mm] 44
N [mm] 16
M [mm] 22
I [mm] 87
L [mm] 146
A [mm] 40
C [mm] 82.2
Ø2 [mm] 38
Ø3 [mm] 41.5
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
IN60-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 44
N [mm] 19
M [mm] 22
I [mm] 87
L [mm] 149
A [mm] 40
C [mm] 82.2
Ø2 [mm] 38
Ø3 [mm] 41.5
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN60-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 44
N [mm] 23
M [mm] 24
I [mm] 89
L [mm] 155
A [mm] 40
C [mm] 82.2
Ø2 [mm] 38
Ø3 [mm] 41.5
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN60-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 44
N [mm] 14
M [mm] 20
I [mm] 85
L [mm] 131.5
A [mm] 40
C [mm] 71.5
Ø2 [mm] 33.5
Ø3 [mm] 37.1
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN60-M14
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M14
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 15
B [mm] 44
N [mm] 16
M [mm] 22
I [mm] 87
L [mm] 135.5
A [mm] 40
C [mm] 71.5
Ø2 [mm] 33.5
Ø3 [mm] 37.1
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN60-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 44
N [mm] 19
M [mm] 22
I [mm] 87
L [mm] 138.5
A [mm] 40
C [mm] 71.5
Ø2 [mm] 33.5
Ø3 [mm] 37.1
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN60-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 240
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 21
B [mm] 44
N [mm] 23
M [mm] 24
I [mm] 89
L [mm] 144.5
A [mm] 40
C [mm] 71.5
Ø2 [mm] 33.5
Ø3 [mm] 37.1
Ø [mm] 23.7
Cable stripping length [mm] 44
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 5
ROHS compliant –
EN 45545-2 certification (r22) HL2
EN80-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 300
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 13.2
B [mm] 51
N [mm] 19
M [mm] 22
I [mm] 94
L [mm] 162.7
A [mm] 42
C [mm] 90.3
Ø2 [mm] 37.7
Ø3 [mm] 41.5
Ø [mm] 27
Cable stripping length [mm] 47
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant Yes
EN 45545-2 certification (r22) HL2
EN80-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour blue
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 300
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free Yes
ØD [mm] 17
B [mm] 51
N [mm] 19
M [mm] 22
I [mm] 94
L [mm] 162.7
A [mm] 42
C [mm] 90.3
Ø2 [mm] 37.7
Ø3 [mm] 41.5
Ø [mm] 27
Cable stripping length [mm] 47
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 10
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN80-M12
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M12
Range of cable cross section (flexible) [mm²] 300
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 13.2
B [mm] 51
N [mm] 19
M [mm] 22
I [mm] 94
L [mm] 163
A [mm] 42
C [mm] 90.8
Ø2 [mm] 41.1
Ø3 [mm] 45.4
Ø [mm] 27
Cable stripping length [mm] 47
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 5
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN80-M16
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M16
Range of cable cross section (flexible) [mm²] 300
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 17
B [mm] 51
N [mm] 19
M [mm] 22
I [mm] 94
L [mm] 163
A [mm] 42
C [mm] 90.8
Ø2 [mm] 41.1
Ø3 [mm] 45.4
Ø [mm] 27
Cable stripping length [mm] 47
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 5
ROHS compliant –
EN 45545-2 certification (r22) HL2
IN80-M20
Minimum operating temperature [°c] -20
Maximum operating temperature [°c] 115
Threshold of operating temperature for short periods [°c] 130
Spy hole Yes
Number of holes on the palm 1
Insulated cover colour red
Type of insulation partial
Easy insertion input Yes
Surface treatment tin plating
Screw pitch M20
Range of cable cross section (flexible) [mm²] 300
Range of cable cross section (low stranded) [mm²] –
Conductor body material Electrolitic copper with purity above 99.95%
Insulated cover material Polyamide
Annealing Yes
Halogen free –
ØD [mm] 21
B [mm] 51
N [mm] 23
M [mm] 24
I [mm] 96
L [mm] 169
A [mm] 42
C [mm] 90.8
Ø2 [mm] 41.1
Ø3 [mm] 45.4
Ø [mm] 27
Cable stripping length [mm] 47
Unit in minimal packaging [pce] 5
Unit in standard packaging [pce] 5
ROHS compliant –
EN 45545-2 certification (r22) HL2

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data