P-M Ring tongue terminal

RING TONGUE TERMINAL, PRE-INSULATED WITH POLYCARBONATE, FOR COPPER CONDUCTORS, HALOGEN FREE
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
The insulated ring cable lugs of the P-M series are made from electrolytic copper strip with a purity of over 99.9% and undergo annealing and electrolytic tin-plating processes to facilitate crimping and increase resistance to mechanical stress.
They are fitted with a polycarbonate insulated cover with an internal funnel-shaped profile, designed to facilitate the insertion of the conductor and help prevent the wires from being crimped during wiring.
The internal knurling of the barrel improves the contact between the conductor and the connector, helping to increase traction and the long-term reliability of the connection.
The P-M series cable lugs are UL-certified and comply with the EN 45545-2 standard.
Read all Close

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
115   °C
Threshold of operating temperature for short periods
130   °C
Number of holes on the palm
1
Type of insulation
partial
Easy insertion input
Yes
Surface treatment
tin plating
Conductor body material
Electrolitic copper with purity above 99,95%
Insulated cover material
Polycarbonate
Annealing
Yes
Halogen free
Yes
Unit in minimal packaging
100   PCE
Customs code
85369010
ROHS compliant
Yes
Self-extinguishing fire class according to UL 94
V0
UL standard
486A-486B

drwr-dim
VP-M
Insulated cover colour green
Range of cable cross section [mm²] 0.2 ÷ 0.5
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Unit in standard packaging [pce] EN 45545-2 certification (r22) EN 45545-2 certification (r23)
VP-M2 M2 2.2 5.6 2.8 4.5 8.7 17.3 4.6 10 3 4.4 1.2 5 4000 HL2 HL3
VP-M3 M3 3.2 5.6 2.8 4.5 8.7 17.3 4.6 10 3 4.4 1.2 5 4000 HL2 HL3
VP-M3.5 M3.5 3.7 5.6 2.8 4.5 8.7 17.3 4.6 10 3 4.4 1.2 5 4000 HL2 HL3
VP-M4 M4 4.3 7 3.5 6.5 10.7 20.3 4.6 10 3 4.4 1.2 5 4000 HL2 HL3
VP-M5 M5 5.3 7.8 3.9 7.1 11.3 21 4.6 10 3 4.4 1.2 5 4000 HL2 HL3
VP-M6 M6 6.4 9.4 4.7 8.1 12.3 21.8 4.6 10 3 4.4 1.2 5 4000 HL2 HL3
RP-M
Insulated cover colour red
Range of cable cross section [mm²] 0.25 ÷ 1.5
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Unit in standard packaging [pce] EN 45545-2 certification (r22) EN 45545-2 certification (r23)
RP-M2 M2 2.2 5.6 2.8 4.5 8.7 17.4 4.2 10.1 4 5.5 1.8 5 3000 HL2 HL3
RP-M3 M3 3.2 5.6 2.8 4.5 8.7 17.4 4.2 10.1 4 5.5 1.8 5 3000 HL2 HL3
RP-M3.5 M3.5 3.7 5.6 2.8 4.5 8.7 17.4 4.2 10.1 4 5.5 1.8 5 3000 HL2 HL3
RP-M3.5/1 M3.5 3.7 6.2 3.1 7.1 11.3 20.3 4.2 10.1 4 5.5 1.8 5 3000 HL2 HL3
RP-M4 M4 4.3 7 3.5 6.5 10.7 20.1 4.2 10.1 4 5.5 1.8 5 3000 HL2 HL3
RP-M4/3 M4 4.3 7.8 3.9 7.1 11.3 21.1 4.2 10.1 4 5.5 1.8 5 3000 HL2 HL3
RP-M5 M5 5.3 7.8 3.9 7.1 11.3 21.1 4.2 10.1 4 5.5 1.8 5 2500 HL2 HL3
RP-M6 M6 6.4 9.4 4.7 8.1 12.3 22.9 4.2 10.1 4 5.5 1.8 5 2500 HL2 HL3
RP-M6/1 M6 6.4 12 6 10.3 14.5 26.4 4.2 10.1 4 5.5 1.8 5 2000 HL2 HL3
RP-M7 M7 7.2 9.4 4.7 8.1 12.3 22.9 4.2 10.1 4 5.5 1.8 5 2500 HL2 HL3
RP-M8 M8 8.4 12 6 10.3 14.5 26.4 4.2 10.1 4 5.5 1.8 5 2500 HL2 HL3
RP-M10 M10 10.5 15.5 7.75 13.05 17.25 30.9 4.2 10.1 4 5.5 1.8 5 1500 HL2 HL3
RP-M12 M12 13 18 9 15.5 19.7 34.6 4.2 10.1 4 5.5 1.8 5 1500 HL2 HL3
BP-M
Insulated cover colour blue
Range of cable cross section [mm²] 1.5 ÷ 2.5
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Unit in standard packaging [pce] EN 45545-2 certification (r22) EN 45545-2 certification (r23)
BP-M2 M2 2.2 5.6 2.8 5 9.2 17.9 4.2 10.1 4.9 6.4 2.4 5 2500 HL2 HL3
BP-M3 M3 3.2 5.6 2.8 5 9.2 17.9 4.2 10.1 4.9 6.4 2.4 5 2500 HL2 HL3
BP-M3.5 M3.5 3.7 5.6 2.8 5 9.2 17.9 4.2 10.1 4.9 6.4 2.4 5 3000 HL2 HL3
BP-M3.5/1 M3.5 3.7 6.2 3.1 6.5 10.7 19.7 4.2 10.1 4.9 6.4 2.4 5 2500 HL2 HL3
BP-M4 M4 4.3 8 4 6.5 10.7 20.6 4.2 10.1 4.9 6.4 2.4 5 2500 HL2 HL3
BP-M5 M5 5.3 8 4 7.5 11.7 21.6 4.2 10.1 4.9 6.4 2.4 5 2000 HL2 HL3
BP-M6 M6 6.4 9.4 4.7 8.6 12.8 23.4 4.2 10.1 4.9 6.4 2.4 5 2000 HL2 HL3
BP-M6/1 M6 6.4 12 6 10.3 14.5 26.4 4.2 10.1 4.9 6.4 2.4 5 2000 HL2 HL3
BP-M6/2 M6 6.4 8.4 4.2 5.4 9.6 19.7 4.2 10.1 4.9 6.4 2.4 5 2500 HL2 HL3
BP-M7 M7 7.2 10 5 7.8 12 22.9 4.2 10.1 4.9 6.4 2.4 5 2500 HL2 HL3
BP-M8 M8 8.4 12 6 10.3 14.5 26.4 4.2 10.1 4.9 6.4 2.4 5 1500 HL2 HL3
BP-M10 M10 10.5 15.5 7.75 13.05 17.25 30.9 4.2 10.1 4.9 6.4 2.4 5 1500 HL2 HL3
BP-M12 M12 13 18 9 15.5 19.7 34.6 4.2 10.1 4.9 6.4 2.4 5 1000 HL2 HL3
GP-M
Insulated cover colour yellow
Range of cable cross section [mm²] 4 ÷ 6
Weight and dimensions Logistic
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Unit in standard packaging [pce]
GP-M3 M3 3.2 8 4 8.1 14.5 26.2 8 14.1 6.6 8.1 3.6 7 1000
GP-M3.5 M3.5 3.7 8 4 8.1 14.5 26.2 8 14.1 6.6 8.1 3.6 7 1000
GP-M4 M4 4.3 9 4.5 8.1 14.5 26.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M5 M5 5.3 9 4.5 8.1 14.5 26.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M6 M6 6.4 11 5.5 11.1 17.5 30.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M6/1 M6 6.4 11 5.5 8.1 14.5 27.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M7 M7 7.2 11 5.5 11.1 17.5 30.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M8 M8 8.4 13.6 6.8 12.1 18.5 33 8 14.1 6.6 8.1 3.6 7 800
GP-M8/1 M8 8.4 11 5.5 8.1 14.5 27.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M10 M10 10.5 13.6 6.8 12.1 18.5 33 8 14.1 6.6 8.1 3.6 7 1000
GP-M10/1 M10 10.5 15.5 7.75 13.85 20.25 35.7 8 14.1 6.6 8.1 3.6 7 1000
GP-M12 M12 13 19 9.5 15.1 21.5 38.7 8 14.1 6.6 8.1 3.6 7 500
GP-M14 M14 15 21 10.5 16.1 22.5 40.7 8 14.1 6.6 8.1 3.6 7 500
GP-M16 M16 17 24 12 17.1 23.5 43.2 8 14.1 6.6 8.1 3.6 7 500

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data