ANE-M RING TERMINAL

RING TERMINAL, PRE-INSULATED WITH PA 6.6, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
ANE-M series lugs are manufactured from electrolytic Copper tube with a purity greater than 99.9%, annealed and Tin plated. The interior of the PA6.6 insulated sleeve is funnel shaped so as to ensure complete and easy introduction of the conductor strands. It also eliminates the need to insulate the terminal using either tape or heat shrinkable tubing. Furthermore the PA6.6 sleeve avoids the possibility of conductor breakage at the barrel entrance.
Read all Close

Features
  • Technical information
  • Material composition and treatments
  • Classification and data ordering
Minimum operating temperature
-20   °C
Maximum operating temperature
115   °C
Threshold of operating temperature for short periods
130   °C
Spy hole
Yes
Type of insulation
partial
Easy insertion input
Yes
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Insulated cover material
Polyamide PA6.6
Annealing
Yes
Customs code
85369010

ANE2-M
Range of cable cross section 10 ÷ 10 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Insulated cover colour Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE2-M4 1 Black tin plating No M4 4.3 10 4 5 18.5 34.1 8 21 8 9.5 4.6 12 4,220 bag; box 100 500 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE2-M5 1 Black tin plating No M5 5.3 10 6 6.5 20 37.6 8 21 8 9.5 4.6 12 4,720 bag; box 100 500 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE2-M6 1 Black tin plating No M6 6.4 11 6 7 20.5 38.1 8 21 8 9.5 4.6 12 4,500 bag; box 100 500 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE2-M8 1 Black tin plating No M8 8.4 15 8 9 22.5 42.1 8 21 8 9.5 4.6 12 4,940 bag; box 100 500 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE2-M10 1 Black tin plating No M10 10.5 18 10 11 24.5 46.1 8 21 8 9.5 4.6 12 5,560 bag; box 100 500 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE2-M12 1 Black tin plating No M12 13.2 19 12 14 27.5 51.1 8 21 8 9.5 4.6 12 5,640 bag; box 100 500 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANB2-M5 Blue tin plating No M5 5.3 10 6 6.5 20 37.6 8 21 8 9.5 4.6 9 Yes
ANB2-M6 Blue No M6 6.4 11 6 7 20.5 38.1 8 21 8 9.5 4.6 8.8 Yes
ANB2-M8 Blue No M8 8.4 15 8 9 22.5 42.1 8 21 8 9.5 4.6 8.8 Yes
ANB2-M10 Blue No M10 10.5 18 10 11 24.5 46.1 8 21 8 9.5 4.6 8.8 Yes
ANB2-M12 Blue tin plating No M12 13.2 19 12 14 27.5 51.1 8 21 8 9.5 4.6 9 Yes
ANE3-M
Range of cable cross section 16 ÷ 16 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Insulated cover colour Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE3-M4 1 Black tin plating No M4 4.3 11.5 4 5 21.5 38.6 11.5 24 9.2 10.5 5.8 13 5,443 bag; box 100 400 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE3-M5 1 Black tin plating No M5 5.3 11.5 6 6.5 23 42.1 11.5 24 9.2 10.5 5.8 13 6,072 bag; box 100 400 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE3-M6 1 Black tin plating No M6 6.4 11.5 6 7 23.5 42.6 11.5 24 9.2 10.5 5.8 13 6,080 bag; box 100 400 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE3-M8 1 Black tin plating No M8 8.4 15 8 9 25.5 46.6 11.5 24 9.2 10.5 5.8 13 6,595 bag; box 100 400 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE3-M10 1 Black tin plating No M10 10.5 18 10 11 27.5 50.6 11.5 24 9.2 10.5 5.8 13 7,220 bag; box 100 300 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE3-M12 1 Black tin plating No M12 13.2 20 12 14 32 57.1 11.5 24 9.2 10.5 5.8 13 7,379 bag; box 100 300 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANB3-M5 Blue tin plating No M5 5.3 11.5 6 6.5 23 42.1 11.5 24 9.2 10.5 5.8 13 Yes
ANB3-M6 Blue No M6 6.4 11.5 6 7 22.5 42.6 11.5 24 9.2 10.5 5.8 12.6 Yes
ANB3-M8 Blue No M8 8.4 15 8 9 25.5 46.6 11.5 24 9.2 10.5 5.8 12.6 Yes
ANB3-M10 Blue No M10 10.5 18 10 11 27.5 50.6 11.5 24 9.2 10.5 5.8 12.6 Yes
ANB3-M12 Blue tin plating M12 13.2 20 12 14 32 55.6 11.5 24 9.2 10.5 5.8 13
ANE5-M
Range of cable cross section 25 ÷ 25 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Insulated cover colour Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE5-M4 1 Black tin plating No M4 4.3 14 4 5 24 41 10.5 25 11.1 13 7 14 8,088 bag; box 100 300 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE5-M5 1 Black tin plating No M5 5.3 14 6 6.5 25.5 44.5 10.5 25 11.1 13 7 14 8,980 bag; box 100 300 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE5-M6 1 Black tin plating No M6 6.4 14 6 7 26 45 10.5 25 11.1 13 7 14 8,920 bag; box 100 300 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE5-M8 1 Black tin plating No M8 8.4 15 8 9 28 49 10.5 25 11.1 13 7 14 9,400 bag; box 100 300 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE5-M10 1 Black tin plating No M10 10.5 18 10 11 30 53 10.5 25 11.1 13 7 14 10,160 bag; box 100 200 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE5-M12 1 Black tin plating No M12 13.2 21 12 14 33 58 10.5 25 11.1 13 7 14 10,740 bag; box 50 200 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANB5-M6 Blue No M6 6.4 14 6 7 26 45 10.5 25 11.1 13 7 11.5 Yes
ANB5-M8 Blue No M8 8.4 15 8 9 28 49 10.5 25 11.1 13 7 11.5 Yes
ANB5-M10 Blue No M10 10.5 18 10 11 30 53 10.5 25 11.1 13 7 11.5 Yes
ANB5-M12 Blue tin plating M12 13.2 21 12 14 33 58 10.5 25 11.1 13 7 12
ANE7-M
Insulated cover colour Black
Range of cable cross section 35 ÷ 35 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE7-M6 1 tin plating No M6 6.4 17 6 7 28.5 51 13.2 30.3 13.6 15.5 8.9 16 14,440 bag; box 50 100 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE7-M8 1 tin plating No M8 8.4 17 8 9 30.5 55 13.2 30.3 13.6 15.5 8.9 16 15,640 bag; box 50 100 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE7-M10 1 tin plating No M10 10.5 19 10 11 32.5 59 13.2 30.3 13.6 15.5 8.9 16 16,560 bag; box 50 100 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE7-M12 1 tin plating No M12 13.2 21 12 14 35.5 64 13.2 30.3 13.6 15.5 8.9 16 17,960 bag; box 50 100 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE10-M
Insulated cover colour Black
Range of cable cross section 50 ÷ 50 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE10-M6 1 tin plating No M6 6.4 19 7 8 30.5 53 16.5 30.5 13.8 15.8 10 18 20,360 bag; box 50 150 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE10-M8 1 tin plating No M8 8.4 19 8 9 32.5 55 16.5 30.5 13.8 15.8 10 18 21,160 bag; box 50 150 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE10-M10 1 tin plating No M10 10.5 20 9.5 11.5 35 59 16.5 30.5 13.8 15.8 10 18 22,240 bag; box 50 150 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE10-M12 1 tin plating No M12 13.2 21 12 12 35.5 62 16.5 30.5 13.8 15.8 10 18 23,600 bag; box 50 150 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE14-M
Insulated cover colour Black
Range of cable cross section 70 ÷ 70 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE14-M6 1 tin plating No M6 6.4 21 7 8 37 61 18 36.1 15.8 18 11.3 23 27,760 bag; box 25 75 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE14-M8 1 tin plating No M8 8.4 21 8 9 38 63 18 36.1 15.8 18 11.3 23 28,800 bag; box 25 75 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE14-M10 1 tin plating No M10 10.5 21 10 11 40 67 18 36.1 15.8 18 11.3 23 30,160 bag; box 25 75 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE14-M12 1 tin plating No M12 13.2 22 12 14 43 72 18 36.1 15.8 18 11.3 23 31,160 bag; box 25 75 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE14-M14 1 tin plating No M14 15 25 14 16 45 76 18 36.1 15.8 18 11.3 23 32,960 bag; box 25 100 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE19-M
Insulated cover colour Black
Range of cable cross section 95 ÷ 95 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE19-M8 1 tin plating No M8 8.4 25 8 9 44.5 73 22.5 43.5 18 20.5 13.5 25 47,120 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE19-M10 1 tin plating No M10 10.5 25 10 11 46.5 77 22.5 43.5 18 20.5 13.5 25 49,132 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE19-M12 1 tin plating No M12 13.2 25 12 14 49.5 82 22.5 43.5 18 20.5 13.5 25 52,000 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE19-M14 1 tin plating No M14 15 25 14 16 51.5 86 22.5 43.5 18 20.5 13.5 25 54,080 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE19-M16 1 tin plating No M16 17 27 16 18 53.5 90 22.5 43.5 18 20.5 13.5 25 56,160 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE24-M
Insulated cover colour Black
Range of cable cross section 120 ÷ 120 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE24-M10 1 tin plating No M10 10.5 28.5 10 11 48 77.7 24 42.75 20 22.7 15.2 28 63,040 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE24-M12 1 tin plating No M12 13.2 28.5 12 14 51 82.7 22.5 42.75 20 22.7 15.2 28 66,000 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE24-M14 1 tin plating No M14 15 28.5 14 16 53 86.7 24 42.75 20 22.7 15.2 28 68,960 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE24-M16 1 tin plating No M16 17 28.5 16 18 55 90.7 24 42.75 20 22.7 15.2 28 74,400 bag; box 25 50 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE30-M
Insulated cover colour Black
Range of cable cross section 150 ÷ 150 mm²
Technical information Weight and dimensions Logistic Classification and data ordering Certifications
tipo Number of holes on the palm Surface treatment Reinforced with anti-vibration collar Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g] Type of packaging Unit in minimal packaging [pce] Unit in standard packaging [pce] Electrocode ETIM Class 7 UL standard ROHS compliant
ANE30-M12 1 tin plating No M12 13.2 31.5 14 16 61 101 26.5 52.2 23 26.6 16.7 35 98,070 bag; box 10 20 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE30-M14 1 tin plating No M14 15 31.5 16 18 63 105 26.5 52.2 23 26.6 16.7 35 101,600 bag; box 15 30 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE30-M16 1 tin plating No M16 17 31.5 17 19 64 107 26.5 52.2 23 26.6 16.7 35 99,380 bag; box 15 30 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes
ANE30-M20 1 tin plating No M20 21 31.5 20 22 67 113 26.5 52.2 23 26.6 16.7 35 103,700 bag; box 15 30 3684 Tube cable lug for copper conductors [EC001051] UL 486A-486B Yes

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data