PL-M Through connector

THROUGH CONNECTOR, PRE-INSULATED WITH PVC, FOR COPPER CONDUCTORS
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
The PL-M series insulated butt joints enable reliable connections to be made on copper conductors.
They are made from high-purity electrolytic copper tubes and undergo annealing and electrolytic tin-plating processes to facilitate crimping and increase resistance to mechanical stress.
They are fitted with an insulated cover in the form of a funnel-shaped profile, designed to facilitate conductor insertion and help prevent wire kinking during wiring.
The PL-M series insulated butt joints are UL-certified.
Read all Close

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Weight and dimensions
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
80   °C
Threshold of operating temperature for short periods
90   °C
Type of connector
butt through connector
Central stop
Yes
Type of insulation
full
Surface treatment
tin plating
Conductor body material
Electrolitic copper with purity above 99.95%
Insulated cover material
Polyvinylchloride PVC
Annealing
Yes
Cable stripping length
9   mm
Unit in minimal packaging
100   PCE
Customs code
85369010
ROHS compliant
Yes

drwr-dim
PL-M
Technical information Weight and dimensions Logistic Certifications
tipo Insulated cover colour Range of cable cross section [mm²] Ø [mm] Ø2 [mm] L [mm] A [mm] Ø2 [mm] Ø3 [mm] Unit in standard packaging [pce] Self-extinguishing fire class according to UL 94 UL standard
PL01-M green 0.2 - 0.5 2.15 1.15 25 15 3 3.8 3000
PL03-M red 0.25 - 1.5 3.3 1.8 25 15 4 4.7 1000 V0 486C
PL06-M blue 1.5 - 2.5 4 2.42 25 15 5 6.9 1500 V0 486C
PL1-M yellow 4 - 6 5.25 3.6 32 16 6.5 7 500 V0 486C
PL01-M
Insulated cover colour green
Range of cable cross section [mm²] 0.2 - 0.5
Ø [mm] 2.15
Ø2 [mm] 1.15
L [mm] 25
A [mm] 15
Ø2 [mm] 3
Ø3 [mm] 3.8
Unit in standard packaging [pce] 3000
Self-extinguishing fire class according to UL 94 –
UL standard –
PL03-M
Insulated cover colour red
Range of cable cross section [mm²] 0.25 - 1.5
Ø [mm] 3.3
Ø2 [mm] 1.8
L [mm] 25
A [mm] 15
Ø2 [mm] 4
Ø3 [mm] 4.7
Unit in standard packaging [pce] 1000
Self-extinguishing fire class according to UL 94 V0
UL standard 486C
PL06-M
Insulated cover colour blue
Range of cable cross section [mm²] 1.5 - 2.5
Ø [mm] 4
Ø2 [mm] 2.42
L [mm] 25
A [mm] 15
Ø2 [mm] 5
Ø3 [mm] 6.9
Unit in standard packaging [pce] 1500
Self-extinguishing fire class according to UL 94 V0
UL standard 486C
PL1-M
Insulated cover colour yellow
Range of cable cross section [mm²] 4 - 6
Ø [mm] 5.25
Ø2 [mm] 3.6
L [mm] 32
A [mm] 16
Ø2 [mm] 6.5
Ø3 [mm] 7
Unit in standard packaging [pce] 500
Self-extinguishing fire class according to UL 94 V0
UL standard 486C

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data