C-CST Sleeve connector

SLEEVE CONNECTOR, TIN-PLATED, FOR COPPER CONDUCTORS
Certifications & approvals
  • USDA
    USDA

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-50   °C
Maximum operating temperature
150   °C
Surface treatment
tin plating
Crimping geometry
oval
Conductor body material
Electrolitic copper with purity above 99.95%
Annealing
Yes
Customs code
85369010
ROHS compliant
Yes

drwr-dim
C-CST
Technical information Weight and dimensions Logistic
tipo Type of branch circuit Cross section range of the through cable [mm²] Cross section range of the through cable (alternative) [mm²] Cross section range of the branch cable (alternative) [mm²] Cross section range of the branch cable [mm²] C [mm] L [mm] B [mm] Unit in minimal packaging [pce] Unit in standard packaging [pce]
C6-C6ST tap connection; joint connection 2.5 - 6 1.5 - 6 9 9.8 6.4 100 1000
C10-C10ST tap connection; joint connection 10 1.5 - 10 12 12.6 8.4 100 500
C16-C16ST tap connection; joint connection 16 1.5 - 16 17 19.4 12 100 400
C25-C10ST tap connection; joint connection 16 - 25 1.5 - 10 17 19.8 13 50 400
C25-C25ST tap connection; joint connection 25 16 - 25 17 21.4 13 50 300
C35-C16ST tap connection; joint connection; joining two running conductors 35 - 40 1.5 - 16 21 24.6 15.4 25 200
C35-C35ST tap connection; joint connection; joining two running conductors 50 35 - 40 10 - 25 25 - 40 21 26.6 15.6 25 200
C70-C25N-ST tap connection; joint connection 63 - 70 1.5 - 25 21 26.4 17.5 50 200
C50-C25ST tap connection; joint connection 50 4 - 25 25 32.9 21 25 75
C50-C50ST tap connection; joint connection 50 35 - 50 26 33 21 25 75
C70-C35ST tap connection; joint connection 50 - 70 4 - 40 28 33 21 25 75
C70-C70ST tap connection; joint connection; joining two running conductors 50 - 70 35 - 70 28 34 21 25 75
C95-C35ST tap connection; joint connection 95 - 100 4 - 40 29 40.6 26 25 50
C95-C70ST tap connection; joint connection; joining two running conductors 95 - 100 40 - 70 29 41 26 25 50
C95-C95ST tap connection; joint connection 95 - 100 63 - 100 29 41 26 25 50
C120-C120ST tap connection; joint connection 110 - 125 25 - 125 30 45 28 15 30
C150-C120ST tap connection; joint connection; joining two running conductors 125 150 - 160 125 25 - 125 31 45 28 15 30
C150-C150ST tap connection; joint connection; joining two running conductors 125 150 125 63 - 150 30 45 28 15 30
C185-C95ST tap connection; joint connection; joining two running conductors 185 16 - 100 31 45 28 15 30
C185-C185ST tap connection; joint connection 120 - 185 120 - 185 22.6 68 34 15 30
C240-C120ST tap connection; joint connection 150 - 240 95 - 120 22.6 68 34 15 30
C6-C6ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 2.5 - 6
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 1.5 - 6
C [mm] 9
L [mm] 9.8
B [mm] 6.4
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 1000
C10-C10ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 10
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 1.5 - 10
C [mm] 12
L [mm] 12.6
B [mm] 8.4
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 500
C16-C16ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 16
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 1.5 - 16
C [mm] 17
L [mm] 19.4
B [mm] 12
Unit in minimal packaging [pce] 100
Unit in standard packaging [pce] 400
C25-C10ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 16 - 25
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 1.5 - 10
C [mm] 17
L [mm] 19.8
B [mm] 13
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 400
C25-C25ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 25
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 16 - 25
C [mm] 17
L [mm] 21.4
B [mm] 13
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 300
C35-C16ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 35 - 40
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 1.5 - 16
C [mm] 21
L [mm] 24.6
B [mm] 15.4
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 200
C35-C35ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 50
Cross section range of the through cable (alternative) [mm²] 35 - 40
Cross section range of the branch cable (alternative) [mm²] 10 - 25
Cross section range of the branch cable [mm²] 25 - 40
C [mm] 21
L [mm] 26.6
B [mm] 15.6
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 200
C70-C25N-ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 63 - 70
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 1.5 - 25
C [mm] 21
L [mm] 26.4
B [mm] 17.5
Unit in minimal packaging [pce] 50
Unit in standard packaging [pce] 200
C50-C25ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 50
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 4 - 25
C [mm] 25
L [mm] 32.9
B [mm] 21
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 75
C50-C50ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 50
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 35 - 50
C [mm] 26
L [mm] 33
B [mm] 21
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 75
C70-C35ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 50 - 70
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 4 - 40
C [mm] 28
L [mm] 33
B [mm] 21
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 75
C70-C70ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 50 - 70
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 35 - 70
C [mm] 28
L [mm] 34
B [mm] 21
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 75
C95-C35ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 95 - 100
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 4 - 40
C [mm] 29
L [mm] 40.6
B [mm] 26
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
C95-C70ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 95 - 100
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 40 - 70
C [mm] 29
L [mm] 41
B [mm] 26
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
C95-C95ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 95 - 100
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 63 - 100
C [mm] 29
L [mm] 41
B [mm] 26
Unit in minimal packaging [pce] 25
Unit in standard packaging [pce] 50
C120-C120ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 110 - 125
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 25 - 125
C [mm] 30
L [mm] 45
B [mm] 28
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
C150-C120ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 125
Cross section range of the through cable (alternative) [mm²] 150 - 160
Cross section range of the branch cable (alternative) [mm²] 125
Cross section range of the branch cable [mm²] 25 - 125
C [mm] 31
L [mm] 45
B [mm] 28
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
C150-C150ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 125
Cross section range of the through cable (alternative) [mm²] 150
Cross section range of the branch cable (alternative) [mm²] 125
Cross section range of the branch cable [mm²] 63 - 150
C [mm] 30
L [mm] 45
B [mm] 28
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
C185-C95ST
Type of branch circuit tap connection; joint connection; joining two running conductors
Cross section range of the through cable [mm²] 185
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 16 - 100
C [mm] 31
L [mm] 45
B [mm] 28
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
C185-C185ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 120 - 185
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 120 - 185
C [mm] 22.6
L [mm] 68
B [mm] 34
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30
C240-C120ST
Type of branch circuit tap connection; joint connection
Cross section range of the through cable [mm²] 150 - 240
Cross section range of the through cable (alternative) [mm²] –
Cross section range of the branch cable (alternative) [mm²] –
Cross section range of the branch cable [mm²] 95 - 120
C [mm] 22.6
L [mm] 68
B [mm] 34
Unit in minimal packaging [pce] 15
Unit in standard packaging [pce] 30

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data