F-U FORK TERMINAL

FORK TERMINAL, PRE-INSULATED WITH PVC, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
These terminals are particularly recommended for use with fl exible conductors. They are manufactured from electrolytic copper tube with a purity greater than 99.9% and with dimension so as to ensure both a good electrical connection and an adequate resistance to vibrations and traction; they are annealed and tin plated. For the same cable section are available different types of connectors with PA6.6 sleeve entry of different diameters so as to accept conductors with various insulation thickness. The insulated sleeve additionally will accept the conductor so avoiding a sudden bending of the conductor itself at the connector entry, highly increasing its resistance to the mechanical solicitations that could break the conductor strands. The operating temperature range is – 20 to + 115°C (Surge + 130°C).
Read all Close

Features
  • Technical information
  • Material composition and treatments
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
75   °C
Threshold of operating temperature for short periods
90   °C
Fork type
flat
Barrel reinforcement ring
No
Markings found
factory mark
Typology
single
Type of insulation
partial
Easy insertion input
Yes
Self-extinguishing fire class according to UL 94
V0
Reinforced with anti-vibration collar
No
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Annealing
Yes
Internal surface of the barrel
knurled
Halogen free
No
Type of packaging
; box
Unit in minimal packaging
100   PCE
Unit in standard packaging
100   PCE
Electrocode
3681
ETIM Class 7
Solderless copper terminals for copper conductors [EC001052]
Customs code
85369010
ROHS compliant
Yes

RF-U
Insulated cover color Red RAL 9005
Range of cable cross section 0.25 ÷ 1.5 mm²
Technical information Material composition and treatments Weight and dimensions
tipo Reference standard Insulated cover material Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
RF-U3 UL 486A-486B; UL 486C PVC M3 5.5 5.5 9.7 3.2 4 19.5 4.2 10.1 4 5 1.8 4.6 0,680
RF-U3.5/2 PVC M3.5 6.4 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4 5 1.8 4.6 0,700
RF-U4 UL 486A-486B; UL 486C PVC M4 6.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4 5 1.8 4.6 0,660
RF-U5 UL 486A-486B; UL 486C PVC M5 8.5 7.5 11.7 5.3 3.7 21.2 4.2 10.1 4 5 1.8 4.6 0,705
RF-U6 UL 486A-486B; UL 486C PVC M6 9.4 8.1 12.3 6.4 4.7 22.8 4.2 10.1 4 5 1.8 4.6 0,740
RF-U8 UL 486A-486B; UL 486C PVC M8 14 10 14.2 8.4 6.3 26.4 4.2 10.1 4 5 1.8 4.6 1,280
RF-U10 UL 486A-486B; UL 486C PVC M10 17.5 13.05 17.25 10.5 7.7 30.8 4.2 10.1 4 5 1.8 4.6 1,520
RF-U12 UL 486A-486B; UL 486C PVC M12 20 15.5 19.7 13 9 34.5 4.2 10.1 4 5 1.8 4.6 1,700
BF-U
Insulated cover color Blue RAL 5015
Range of cable cross section 1.5 ÷ 2.5 mm²
Technical information Material composition and treatments Weight and dimensions
tipo Reference standard Insulated cover material Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
BF-U3 UL 486A-486B; UL 486C PVC polyvinylchloride M3 5.5 5.5 9.7 3.2 4 19.5 4.2 10.1 4.9 6.4 2.4 4.6 0,720
BF-U3.5 UL 486A-486B; UL 486C PVC polyvinylchloride M3.5 6.4 6.5 10.7 3.7 3.8 20.3 4.2 10.1 4.9 6.4 2.4 4.6 0,760
BF-U4 UL 486A-486B; UL 486C PVC polyvinylchloride M4 6.5 7.5 11.7 4.3 3.7 21.2 4.2 10.1 4.9 6.4 2.4 4.6 0,780
BF-U5 UL 486A-486B; UL 486C PVC polyvinylchloride M5 8.5 7.5 11.7 5.3 3.7 21.2 4.2 10.1 4.9 6.4 2.4 4.6 0,811
BF-U6 UL 486A-486B; UL 486C PVC polyvinylchloride M6 9.4 8.1 12.3 6.4 4.7 22.8 4.2 10.1 4.9 6.4 2.4 4.6 0,835
BF-U8 UL 486A-486B; UL 486C PVC polyvinylchloride M8 14 10 14.2 8.4 6.3 26.3 4.2 10.1 4.9 6.4 2.4 4.6 1,445
BF-U10 UL 486A-486B; UL 486C PVC polyvinylchloride M10 17.5 13.05 17.25 10.5 7.75 30.8 4.2 10.1 4.9 6.4 2.4 4.6 1,580
BF-U12 UL 486A-486B; UL 486C PVC polyvinylchloride M12 20 15.5 19.7 13 9 34.5 4.2 10.1 4.9 6.4 2.4 4.6 1,864
GF-U
Insulated cover color Yellow RAL 1021
Range of cable cross section 4 ÷ 6 mm²
Technical information Material composition and treatments Weight and dimensions
tipo Reference standard Insulated cover material Screw diameter B [mm] M [mm] I [mm] D [mm] N [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
GF-U3.5 UL 486A-486B; UL 486C PVC polyvinylchloride M3.5 7.5 8.5 14.9 3.7 3.9 26.5 6.4 14.1 6.6 8.1 3.6 7 1,800
GF-U4 UL 486A-486B; UL 486C PVC polyvinylchloride M4 7.5 8 14.4 4.3 4.4 26.5 6.4 14.1 6.6 8.1 3.6 7 1,761
GF-U5 UL 486A-486B; UL 486C PVC polyvinylchloride M5 9.5 8 14.4 5.3 4.4 26.5 6.4 14.1 6.6 8.1 3.6 7 1,820
GF-U6 UL 486A-486B; UL 486C PVC polyvinylchloride M6 10 11 17.4 6.4 5.5 30.6 6.4 14.1 6.6 8.1 3.6 7 2,000
GF-U8 UL 486A-486B; UL 486C PVC polyvinylchloride M8 13.5 12 18.4 8.4 8 34.1 6.4 14.1 6.6 8.1 3.6 7 2,380
GF-U10 UL 486A-486B; UL 486C PVC polyvinylchloride M10 15.5 13 19.4 10.5 8 35.1 6.4 14.1 6.6 8.1 3.6 7 2,360
GF-U12 UL 486A-486B; UL 486C PVC polyvinylchloride M12 21 15.1 21.5 13 9.5 38.7 6.4 14.1 6.6 8.1 3.6 7 3,020
GF-U14 UL 486A-486B; UL 486C PVC polyvinylchloride M14 23 16.1 22.5 15 10.5 40.7 6.4 14.1 6.6 8.1 3.6 7 3,440
GF-U16 UL 486A-486B; UL 486C PVC polyvinylchloride M16 26 17.1 23.5 17 11.5 42.7 6.4 14.1 6.6 8.1 3.6 7 3,880

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data