F-M RING TERMINAL

RING TERMINAL, PRE-INSULATED WITH PVC, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
These terminals are particularly recommended for use with fl exible conductors. They are manufactured from electrolytic copper tube with a purity greater than 99.9% and with dimension so as to ensure both a good electrical connection and an adequate resistance to vibrations and traction; they are annealed and tin plated. For the same cable section are available different types of connectors with PA6.6 sleeve entry of different diameters so as to accept conductors with various insulation thickness. The insulated sleeve additionally will accept the conductor so avoiding a sudden bending of the conductor itself at the connector entry, highly increasing its resistance to the mechanical solicitations that could break the conductor strands. The operating temperature range is – 20 to + 115°C (Surge + 130°C).
Read all Close

Features
  • Technical information
  • Material composition and treatments
  • Weight and dimensions
  • Logistic
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-20   °C
Maximum operating temperature
75   °C
Threshold of operating temperature for short periods
90   °C
Bend angle of the connection
0   °
Number of holes on the palm
1
Markings found
factory mark
Reference standard
UL 486A-486B; UL 486C
Typology
single
Type of insulation
partial
Easy insertion input
Yes
Self-extinguishing fire class according to UL 94
V0
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Minimum thickness of the surface coating of the conducting body
3   µm
Surface treatment of the conductor body
tin plating
Insulated cover material
PVC polyvinylchloride
Annealing
Yes
Internal surface of the barrel
knurled
Center distance between holes
0   mm
Type of packaging
; box
Unit in minimal packaging
100   PCE
Unit in standard packaging
100   PCE
Electrocode
3681
ETIM Class 7
Solderless copper terminals for copper conductors [EC001052]
Customs code
85369010
ROHS compliant
Yes

RF-M
Insulated cover color Red RAL 9005
Range of cable cross section 0.25 ÷ 1.5 mm²
Weight and dimensions
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
RF-M3 M3 3.2 5.6 2.8 4.5 8.7 17.3 4.2 10.1 4 5.5 1.8 4.6 0,580
RF-M3.5 M3.5 3.7 5.6 2.8 4.5 8.7 17.3 4.2 10.1 4 5.5 1.8 4.6 0,580
RF-M4 M4 4.3 7 3.5 6.5 10.7 20 4.2 10.1 4 5.5 1.8 4.6 0,660
RF-M5 M5 5.3 7.8 3.9 7.1 11.3 21 4.2 10.1 4 5.5 1.8 4.6 0,674
RF-M6 M6 6.4 9.4 4.7 8.1 12.3 22.8 4.2 10.1 4 5.5 1.8 4.6 0,780
RF-M8 M8 8.4 12 6 10.3 14.5 26.3 4.2 10.1 4 5.5 1.8 4.6 1,020
RF-M10 M10 10.5 15.5 7.75 13.05 17.25 30.8 4.2 10.1 4 5.5 1.8 4.6 1,340
RF-M12 M12 13 18 9 15.5 19.7 34.5 4.2 10.1 4 5.5 1.8 4.6 1,533
BF-M
Insulated cover color Blue RAL 5015
Range of cable cross section 1.5 ÷ 2.5 mm²
Weight and dimensions
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
BF-M3 M3 3.2 5.6 2.8 5 9.2 17.8 4.2 10.1 4.9 6.4 2.4 4.6 0,698
BF-M3.5 M3.5 3.7 5.6 2.8 5 9.2 17.8 4.2 10.1 4.9 6.4 2.4 4.6 0,681
BF-M4 M4 4.3 8 4 6.5 10.7 20.5 4.2 10.1 4.9 6.4 2.4 4.6 0,832
BF-M5 M5 5.3 8 4 7.5 11.7 21.5 4.2 10.1 4.9 6.4 2.4 4.6 0,813
BF-M6 M6 6.4 9.4 4.7 8.6 12.8 23.3 4.2 10.1 4.9 6.4 2.4 4.6 0,906
BF-M8 M8 8.4 12 6 10.3 14.5 26.3 4.2 10.1 4.9 6.4 2.4 4.6 1,060
BF-M10 M10 10.5 15.5 7.75 13.05 17.25 30.8 4.2 10.1 4.9 6.4 2.4 4.6 1,429
BF-M12 M12 13 18 9 15.5 19.7 34.5 4.2 10.1 4.9 6.4 2.4 4.6 1,680
GF-M
Insulated cover color Yellow RAL 1021
Range of cable cross section 4 ÷ 6 mm²
Weight and dimensions
tipo Screw diameter ØD [mm] B [mm] N [mm] M [mm] I [mm] L [mm] A [mm] C [mm] Ø2 [mm] Ø3 [mm] Ø [mm] Cable stripping length [mm] Gross weight [g]
GF-M3 M3 3.2 8 4 8.1 14.5 26.2 6.4 14.1 6.6 8.1 3.6 7 1,840
GF-M3.5 M3.5 3.7 8 4 8.1 14.5 26.2 6.4 14.1 6.6 8.1 3.6 7 1,860
GF-M4 M4 4.3 9 4.5 8.1 14.5 26.7 6.4 14.1 6.6 8.1 3.6 7 1,860
GF-M5 M5 5.3 9 4.5 8.1 14.5 26.7 6.4 14.1 6.6 8.1 3.6 7 1,820
GF-M6 M6 6.4 11 5.5 11.1 17.5 30.7 6.4 14.1 6.6 8.1 3.6 7 2,140
GF-M8 M8 8.4 13.6 6.8 12.1 18.5 33 6.4 14.1 6.6 8.1 3.6 7 2,372
GF-M10 M10 10.5 13.6 6.8 12.1 18.5 33 6.4 14.1 6.6 8.1 3.6 7 2,000
GF-M12 M12 13 19 9.5 15.1 21.5 38.7 6.4 14.1 6.6 8.1 3.6 7 3,180
GF-M14 M14 15 21 10.5 16.1 22.5 40.7 6.4 14.1 6.6 8.1 3.6 7 3,172
GF-M16 M16 17 24 12.5 17.1 23.5 43.2 6.4 14.1 6.6 8.1 3.6 7 3,600

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data