2A-M HEAVY DUTY RING TERMINAL

HEAVY DUTY RING TERMINAL, WITHOUT INSPECTION HOLE, WITH LONG NECK, FOR COPPER CONDUCTORS
Documentation
Certifications & approvals
  • UL (cULus)
    UL (cULus)
Description
The 2A-M series cable lugs are designed for heavy duty, for grounding structures and equipment both indoors and outdoors and for medium voltage applications up to 35 kV. 2A-M series terminals are made from high purity Copper tube with a purity greater than 99.9%, and are annealed. They feature a double length barrel for enhanced electrical and mechanical performance in heavy duty applications. The absence of an inspection hole prevents the entry of water or moisture into the crimped joint making these terminals suitable for outdoor applications. The terminals are electrolytically Tin plated to prevent atmospheric corrosion.
Read all Close

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Classification and data ordering
  • Certifications
Minimum operating temperature
-58   °F
Maximum operating temperature
302   °F
Number of holes on the palm
1
Easy insertion input
Yes
Surface treatment
tin plating
Crimping geometry
hexagonal; indent
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Annealing
Yes
Customs code
85369010
ROHS compliant
Yes

drwr-dim
2A3-M
Range of cable cross section (flexible) [awg/kcmil] 6 AWG
Range of cable cross section (low stranded) [awg/kcmil] 6 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A3-M8 M8 0.33 0.59 0.31 0.35 1.4 10 20 1.71 0.87 0.23 0.98 0.31 100 600 486A-486B
2A3-M10 M10 0.41 0.71 0.39 0.43 1.48 20 35 1.87 0.87 0.23 0.98 0.31 100 500 486A-486B
2A5-M
Range of cable cross section (flexible) [awg/kcmil] 4 AWG
Range of cable cross section (low stranded) [awg/kcmil] 4 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A5-M8 M8 0.33 0.59 0.31 0.35 1.69 10 20 2.01 1 0.28 1.14 0.37 100 400 486A-486B
2A5-M10 M10 0.41 0.71 0.39 0.43 1.77 20 35 2.17 1 0.28 1.14 0.37 50 300 486A-486B
2A5-M12 M12 0.52 0.83 0.47 0.55 1.89 40 50 2.36 1 0.28 1.14 0.37 50 300 486A-486B
2A7-M
Range of cable cross section (flexible) [awg/kcmil] 4 AWG ÷ 2 AWG
Range of cable cross section (low stranded) [awg/kcmil] 2 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A7-M8 M8 0.33 0.67 0.31 0.35 1.77 10 20 2.09 1.02 0.35 1.14 0.46 50 200 486A-486B
2A7-M10 M10 0.41 0.75 0.39 0.43 1.85 20 35 2.24 1.02 0.35 1.14 0.46 50 200 486A-486B
2A7-M12 M12 0.52 0.83 0.47 0.55 1.97 40 50 2.44 1.02 0.35 1.14 0.46 50 200 486A-486B
2A10-M
Range of cable cross section (flexible) [awg/kcmil] 2 AWG ÷ 1 AWG
Range of cable cross section (low stranded) [awg/kcmil] 1 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A10-M10 M10 0.41 0.79 0.39 0.43 2.09 20 35 2.48 1.18 0.39 1.3 0.51 50 100 486A-486B
2A10-M12 M12 0.52 0.83 0.47 0.55 2.2 40 50 2.68 1.18 0.39 1.3 0.51 50 100 486A-486B
2A10-M14 M14 0.59 0.98 0.55 0.63 2.28 65 70 2.83 1.18 0.39 1.3 0.51 50 150 486A-486B
2A10-M16 M16 0.67 1.02 0.63 0.71 2.36 90 90 2.99 1.18 0.39 1.3 0.51 50 150 486A-486B
2A14-M
Range of cable cross section (flexible) [awg/kcmil] 1 AWG ÷ 2/0 AWG
Range of cable cross section (low stranded) [awg/kcmil] 2/0 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A14-M10 M10 0.41 0.83 0.39 0.43 2.36 20 35 2.76 1.42 0.44 1.57 0.57 50 100 486A-486B
2A14-M12 M12 0.52 0.87 0.47 0.55 2.48 40 50 2.95 1.42 0.44 1.57 0.57 50 100 486A-486B
2A14-M14 M14 0.59 0.98 0.55 0.63 2.56 65 70 3.11 1.42 0.44 1.57 0.57 50 100 486A-486B
2A14-M16 M16 0.67 1.02 0.63 0.71 2.64 90 90 3.27 1.42 0.44 1.57 0.57 50 100 486A-486B
2A19-M
Range of cable cross section (flexible) [awg/kcmil] 2/0 AWG ÷ 3/0 AWG
Range of cable cross section (low stranded) [awg/kcmil] 3/0 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A19-M10 M10 0.41 0.98 0.39 0.43 2.62 20 35 3.01 1.57 0.53 1.73 0.69 25 50 486A-486B
2A19-M12 M12 0.52 0.98 0.47 0.55 2.74 40 50 3.21 1.57 0.53 1.73 0.69 25 50 486A-486B
2A19-M14 M14 0.59 0.98 0.55 0.63 2.81 65 70 3.37 1.57 0.53 1.73 0.69 25 75 486A-486B
2A19-M16 M16 0.67 1.06 0.63 0.71 2.89 90 90 3.56 1.57 0.53 1.73 0.69 25 50 486A-486B
2A19-M20 M20 0.83 1.14 0.79 0.87 3.05 150 3.84 1.57 0.53 1.73 0.69 25 50 486A-486B
2A24-M
Range of cable cross section (flexible) [awg/kcmil] 3/0 AWG ÷ 4/0 AWG
Range of cable cross section (low stranded) [awg/kcmil] 4/0 AWG
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A24-M10 M10 0.41 1.12 0.39 0.43 2.83 20 35 3.23 1.65 0.6 1.85 0.77 15 30 486A-486B
2A24-M12 M12 0.52 1.12 0.47 0.55 2.95 40 50 3.43 1.65 0.6 1.85 0.77 15 30 486A-486B
2A24-M14 M14 0.59 1.12 0.55 0.63 3.03 65 70 3.58 1.65 0.6 1.85 0.77 15 30 486A-486B
2A24-M16 M16 0.67 1.12 0.63 0.71 3.11 90 90 3.74 1.65 0.6 1.85 0.77 15 30 486A-486B
2A24-M20 M20 0.83 1.18 0.79 0.87 3.27 150 4.06 1.65 0.6 1.85 0.77 25 50 486A-486B
2A30-M
Range of cable cross section (flexible) [awg/kcmil] 4/0 AWG ÷ 300 kcmil
Range of cable cross section (low stranded) [awg/kcmil] 300 kcmil
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A30-M10 M10 0.41 1.24 0.43 0.51 3.19 20 35 3.62 1.93 0.66 2.13 0.85 15 30 486A-486B
2A30-M12 M12 0.52 1.24 0.55 0.63 3.31 40 50 3.86 1.93 0.66 2.13 0.85 15 30 486A-486B
2A30-M14 M14 0.59 1.24 0.63 0.71 3.39 65 70 4.02 1.93 0.66 2.13 0.85 15 30 486A-486B
2A30-M16 M16 0.67 1.24 0.67 0.75 3.43 90 90 4.09 1.93 0.66 2.13 0.85 15 30 486A-486B
2A30-M20 M20 0.83 1.24 0.79 0.87 3.54 150 4.33 1.93 0.66 2.13 0.85 15 30 486A-486B
2A37-M
Range of cable cross section (flexible) [awg/kcmil] 300 kcmil ÷ 350 kcmil
Range of cable cross section (low stranded) [awg/kcmil] 350 kcmil
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A37-M12 M12 0.52 1.4 0.55 0.63 3.7 40 50 4.25 2.17 0.76 2.4 0.96 10 20 486A-486B
2A37-M14 M14 0.59 1.4 0.63 0.71 3.78 65 70 4.41 2.17 0.76 2.4 0.96 15 30 486A-486B
2A37-M16 M16 0.67 1.4 0.67 0.75 3.82 90 90 4.49 2.17 0.76 2.4 0.96 15 30 486A-486B
2A37-M20 M20 0.83 1.4 0.79 0.87 3.94 150 4.72 2.17 0.76 2.4 0.96 15 30 486A-486B
2A48-M
Range of cable cross section (flexible) [awg/kcmil] 350 kcmil ÷ 500 kcmil
Range of cable cross section (low stranded) [awg/kcmil] 500 kcmil
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A48-M12 M12 0.52 1.54 0.55 0.63 3.74 40 50 4.29 2.17 0.83 2.4 1.07 5 20 486A-486B
2A48-M14 M14 0.59 1.54 0.63 0.71 3.82 65 70 4.45 2.17 0.83 2.4 1.07 5 20 486A-486B
2A48-M16 M16 0.67 1.54 0.67 0.75 3.86 90 90 4.53 2.17 0.83 2.4 1.07 5 20 486A-486B
2A48-M20 M20 0.83 1.54 0.79 0.87 3.58 150 4.76 2.17 0.83 2.4 1.07 5 25 486A-486B
2A60-M
Range of cable cross section (flexible) [awg/kcmil] 500 kcmil ÷ 600 kcmil
Range of cable cross section (low stranded) [awg/kcmil] 600 kcmil
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A60-M12 M12 0.52 1.18 0.55 0.79 4.55 40 50 5.1 2.76 0.93 3.03 1.2 5 15 486A-486B
2A60-M14 M14 0.59 1.18 0.63 0.87 4.63 65 70 5.26 2.76 0.93 3.03 1.2 5 15 486A-486B
2A60-M16 M16 0.67 1.57 0.75 0.87 4.63 90 90 5.37 2.76 0.93 3.03 1.2 5 15 486A-486B
2A60-M20 M20 0.83 1.57 0.91 0.94 4.7 150 5.61 2.76 0.93 3.03 1.2 5 15 486A-486B
2A80-M
Range of cable cross section (flexible) [awg/kcmil] 600 kcmil
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A80-M12 M12 0.52 2.01 0.75 0.87 4.76 40 50 5.51 2.76 1.06 3.03 1.38 5 10 486A-486B
2A80-M14 M14 0.59 2.01 0.75 0.87 4.76 65 70 5.51 2.76 1.06 3.03 1.38 5 10 486A-486B
2A80-M16 M16 0.67 2.01 0.75 0.87 4.76 90 90 5.51 2.76 1.06 3.03 1.38 5 10 486A-486B
2A80-M20 M20 0.83 2.01 0.91 0.94 4.84 150 5.75 2.76 1.06 3.03 1.38 5 15 486A-486B
2A100-M
Weight and dimensions Logistic Certifications
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] UL standard
2A100-M16 M16 0.67 2.22 0.75 0.87 4.8 90 90 5.55 2.64 1.19 2.91 1.56 1 10 486A-486B
2A100-M20 M20 0.83 2.22 0.91 0.94 4.88 150 5.79 2.64 1.19 2.91 1.56 1 10 486A-486B
2A120-M
Weight and dimensions Logistic
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (high conductivity screw) [nm] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce]
2A120-M16 M16 0.67 2.42 0.75 0.87 5.51 90 90 6.26 3.35 1.31 3.7 1.68 1 8
2A120-M20 M20 0.83 2.42 0.91 0.94 5.59 150 6.5 3.35 1.31 3.7 1.68 1 20
2A160-M
Weight and dimensions Logistic
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce]
2A160-M20 M20 0.83 2.83 0.91 0.94 6.46 150 7.36 3.94 1.5 4.33 1.97 1 12
2A200-M
Weight and dimensions Logistic
tipo Screw diameter ØD [in] B [in] N [in] M [in] I [in] Tightening torque (8.8 grade screw) [nm] L [in] A [in] Ø [in] Cable stripping length [in] Ø1 [in] Unit in minimal packaging [pce] Unit in standard packaging [pce]
2A200-M20 M20 0.83 3.23 0.91 0.94 7.05 150 7.95 4.33 1.73 4.76 2.2 1 6

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm