C-CST SLEEVE CONNECTOR

SLEEVE CONNECTOR, TIN-PLATED, FOR COPPER CONDUCTORS
Certifications & approvals
  • USDA
    USDA

Common features in table.

Features
Details by type in expandable section below.
  • Technical information
  • Material composition and treatments
  • Classification and data ordering
Minimum operating temperature
-58   °F
Maximum operating temperature
302   °F
Surface treatment
tin plating
Crimping geometry
oval
Conductor body material
Rame elettrolitico con purezza superiore al 99,95%
Annealing
Yes
Customs code
85369010

drwr-dim
C-CST
Technical information Weight and dimensions Logistic Certifications
tipo Type of branch circuit Cross section range of the through cable [awg/kcmil] Cross section range of the through cable (01) [awg/kcmil] Cross section range of the through cable (crocera) [awg/kcmil] Cross section range of the branch cable [awg/kcmil] Cross section range of the branch cable (01) [awg/kcmil] Cross section range of the branch cable (crocera) [awg/kcmil] C [in] L [in] B [in] Unit in minimal packaging [pce] Unit in standard packaging [pce] ROHS compliant
C6-C6ST tap connection; joint connection 14 AWG - 10 AWG 16 AWG - 10 AWG 0.35 0.39 0.25 100 1000 Yes
C10-C10ST tap connection; joint connection 8 AWG 16 AWG - 8 AWG 0.47 0.5 0.33 100 500 Yes
C16-C16ST tap connection; joint connection 6 AWG 16 AWG - 6 AWG 0.67 0.76 0.47 100 400 Yes
C25-C10ST tap connection; joint connection 6 AWG - 4 AWG 16 AWG - 8 AWG 0.67 0.78 0.51 50 400 Yes
C25-C25ST tap connection; joint connection 4 AWG 6 AWG - 4 AWG 0.67 0.84 0.51 50 300 Yes
C35-C16ST tap connection; joint connection; joining two running conductors 2 AWG; 4 AWG 16 AWG - 6 AWG; 4 AWG 0.83 0.97 0.61 25 200 Yes
C35-C35ST tap connection; joint connection; joining two running conductors 1 AWG; 2 AWG; 2 AWG 8 AWG - 4 AWG; 4 AWG; 2 AWG 0.83 1.05 0.61 25 200 Yes
C70-C25N-ST tap connection; joint connection - 2/0 AWG 16 AWG - 4 AWG 0.83 1.04 0.69 50 200 Yes
C50-C25ST tap connection; joint connection 1 AWG 12 AWG - 4 AWG 0.98 1.3 0.83 25 75 Yes
C50-C50ST tap connection; joint connection 1 AWG 2 AWG - 1 AWG 1.02 1.3 0.83 25 75 Yes
C70-C35ST tap connection; joint connection 1 AWG - 2/0 AWG 12 AWG 1.1 1.3 0.83 25 75 Yes
C70-C70ST tap connection; joint connection; joining two running conductors 1 AWG - 2/0 AWG; 1 AWG 2 AWG - 2/0 AWG; 1 AWG 1.1 1.34 0.83 25 75 Yes
C95-C35ST tap connection; joint connection 3/0 AWG 12 AWG 1.14 1.6 1.02 25 50 Yes
C95-C70ST tap connection; joint connection; joining two running conductors 3/0 AWG; - 2/0 AWG - 2/0 AWG; - 2/0 AWG 1.14 1.61 1.02 25 50 Yes
C95-C95ST tap connection; joint connection 3/0 AWG 1.14 1.61 1.02 25 50 Yes
C120-C120ST tap connection; joint connection 4 AWG 1.18 1.77 1.1 15 30 Yes
C150-C120ST tap connection; joint connection; joining two running conductors 300 kcmil 3/0 AWG - 4/0 AWG 4 AWG 3/0 AWG - 4/0 AWG 1.22 1.77 1.1 15 30 Yes
C150-C150ST tap connection; joint connection; joining two running conductors 300 kcmil - 300 kcmil 1.18 1.77 1.1 15 30 Yes
C185-C95ST tap connection; joint connection; joining two running conductors 350 kcmil; 4/0 AWG 6 AWG; 4/0 AWG 1.22 1.77 1.1 15 30 Yes
C185-C185ST tap connection; joint connection 4/0 AWG - 350 kcmil 4/0 AWG - 350 kcmil 0.89 2.68 1.34 15 30 Yes
C240-C120ST tap connection; joint connection 300 kcmil - 500 kcmil 3/0 AWG - 4/0 AWG 0.89 2.68 1.34 15 30 Yes

Follow us

Subscribe to CEMBRE newsletter and stay tuned

Print label service

Fill in the form and follow the instructions to request the label print service

1. User data

2. Company data

3. Print type

4. Label specs

Orientation

Label size

A x B mm

5. Graphic specs

Graphic size

H x W mm

Graphic position

X x Y mm

6. Request data