PKD Wire ferrules
Wire ferrules, pre-insulated with PA6, for flexible copper conductors
Gallery
PKD
Wire ferrules, pre-insulated with PA6, for flexible copper conductors
Certifications & approvals
-
UL (cULus)
Description
The PKD series insulated wire ferrules enable reliable connections on copper conductors.
They are manufactured from high-purity electrolytic copper tubing and undergo annealing and electrolytic tin-plating processes to facilitate crimping and increase resistance to mechanical stress.
They feature a halogen-free PA6 insulating sleeve, which helps keep conductor strands compact and improves connection reliability.
The wire ferrules of the PKD series are UL-certified and comply with the EN 45545-2 standard. They are the ideal solution for facilitating conductor insertion into terminals with limited available space, while keeping copper strands compact.
Read all
Close
They are manufactured from high-purity electrolytic copper tubing and undergo annealing and electrolytic tin-plating processes to facilitate crimping and increase resistance to mechanical stress.
They feature a halogen-free PA6 insulating sleeve, which helps keep conductor strands compact and improves connection reliability.
The wire ferrules of the PKD series are UL-certified and comply with the EN 45545-2 standard. They are the ideal solution for facilitating conductor insertion into terminals with limited available space, while keeping copper strands compact.
Common features in table.
Features
Details by type in expandable section below.
Easy insertion input
Yes
Surface treatment
tin plating
Conductor body material
Electrolitic copper with purity above 99.95%
Customs code
85369010
PKD
| Technical information | Material composition and treatments | Weight and dimensions | Logistic | Certifications | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| tipo | Minimum operating temperature [°f] | Maximum operating temperature [°f] | Threshold of operating temperature for short periods [°f] | Insulated cover color | Compatible cable class | Range of cable cross section [awg/kcmil] | Insulated cover material | Annealing | Halogen free | C [in] | Ø2 [in] | Ø3 [in] | Cable stripping length [in] | Ø1 [in] | P [in] | L [in] | Unit in minimal packaging [pce] | Unit in standard packaging [pce] | ROHS compliant | EN 45545-2 certification (r22) | EN 45545-2 certification (r23) | Self-extinguishing fire class according to UL 94 | UL standard |
| PKD506 | -4 | 248 | 266 | white | 5 class | 22 AWG - 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.1 | 0.12 | 0.24 | 0.05 | 0.24 | 0.47 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD508 | -4 | 248 | 266 | white | 5 class | 22 AWG - 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.1 | 0.12 | 0.31 | 0.05 | 0.31 | 0.55 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD510 | -4 | 248 | 266 | white | 5 class | 22 AWG - 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.1 | 0.12 | 0.39 | 0.05 | 0.39 | 0.63 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD7506 | -4 | 248 | 266 | grey | 5 class | 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.11 | 0.13 | 0.24 | 0.06 | 0.24 | 0.47 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD7508 | -4 | 248 | 266 | grey | 5 class | 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.11 | 0.13 | 0.31 | 0.06 | 0.31 | 0.55 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD7510 | -4 | 248 | 266 | grey | 5 class | 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.11 | 0.13 | 0.39 | 0.06 | 0.39 | 0.63 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD7512 | -4 | 248 | 266 | grey | 5 class | 20 AWG | Polyamide | Yes | Yes | 0.24 | 0.11 | 0.13 | 0.47 | 0.06 | 0.47 | 0.71 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD106 | -4 | 248 | 266 | red | 5 class | 18 AWG | Polyamide | Yes | Yes | 0.24 | 0.12 | 0.14 | 0.24 | 0.07 | 0.24 | 0.47 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD108 | -4 | 248 | 266 | red | 5 class | 18 AWG | Polyamide | Yes | Yes | 0.24 | 0.12 | 0.14 | 0.31 | 0.07 | 0.31 | 0.55 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD110 | -4 | 248 | 266 | red | 5 class | 18 AWG | Polyamide | Yes | Yes | 0.24 | 0.12 | 0.14 | 0.39 | 0.07 | 0.39 | 0.63 | 500 | 10000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD112 | -4 | 248 | 266 | red | 5 class | 18 AWG | Polyamide | Yes | Yes | 0.24 | 0.12 | 0.14 | 0.47 | 0.07 | 0.47 | 0.71 | 500 | 8000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1508 | -4 | 248 | 266 | black | 5 class | 16 AWG | Polyamide | Yes | Yes | 0.24 | 0.14 | 0.16 | 0.31 | 0.08 | 0.31 | 0.55 | 500 | 5000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1510 | -4 | 248 | 266 | black | 5 class | 16 AWG | Polyamide | Yes | Yes | 0.24 | 0.14 | 0.16 | 0.39 | 0.08 | 0.39 | 0.63 | 500 | 5000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1512 | -4 | 248 | 266 | black | 5 class | 16 AWG | Polyamide | Yes | Yes | 0.24 | 0.14 | 0.16 | 0.47 | 0.08 | 0.47 | 0.71 | 500 | 5000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1518 | -4 | 248 | 266 | black | 5 class | 16 AWG | Polyamide | Yes | Yes | 0.24 | 0.14 | 0.16 | 0.71 | 0.08 | 0.71 | 0.94 | 500 | 5000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD2508 | -4 | 248 | 266 | blue | 5 class | 14 AWG | Polyamide | Yes | Yes | 0.24 | 0.17 | 0.19 | 0.31 | 0.1 | 0.31 | 0.55 | 500 | 5000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD2512 | -4 | 248 | 266 | blue | 5 class | 14 AWG | Polyamide | Yes | Yes | 0.24 | 0.17 | 0.19 | 0.47 | 0.1 | 0.47 | 0.71 | 500 | 4000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD2518 | -4 | 248 | 266 | blue | 5 class | 14 AWG | Polyamide | Yes | Yes | 0.24 | 0.17 | 0.19 | 0.71 | 0.1 | 0.71 | 0.94 | 500 | 5000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD410 | -4 | 248 | 266 | grey | 5 class | 12 AWG | Polyamide | Yes | Yes | 0.28 | 0.19 | 0.21 | 0.39 | 0.13 | 0.39 | 0.67 | 200 | 3000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD412 | -4 | 248 | 266 | grey | 5 class | 12 AWG | Polyamide | Yes | Yes | 0.31 | 0.19 | 0.21 | 0.47 | 0.13 | 0.47 | 0.79 | 200 | 3000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD418 | -4 | 248 | 266 | grey | 5 class | 12 AWG | Polyamide | Yes | Yes | 0.31 | 0.19 | 0.21 | 0.71 | 0.13 | 0.71 | 1.02 | 200 | 3000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD612 | -4 | 248 | 266 | yellow | 5 class | 10 AWG | Polyamide | Yes | Yes | 0.31 | 0.25 | 0.27 | 0.47 | 0.15 | 0.47 | 0.79 | 100 | 1500 | Yes | HL1 | HL2 | V2 | 486F |
| PKD618 | -4 | 248 | 266 | yellow | 5 class | 10 AWG | Polyamide | Yes | Yes | 0.31 | 0.25 | 0.27 | 0.71 | 0.15 | 0.71 | 1.02 | 100 | 1500 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1012 | -4 | 248 | 266 | red | 5 class | 8 AWG | Polyamide | Yes | Yes | 0.39 | 0.3 | 0.33 | 0.47 | 0.19 | 0.47 | 0.87 | 100 | 1000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1018 | -4 | 248 | 266 | red | 5 class | 8 AWG | Polyamide | Yes | Yes | 0.39 | 0.3 | 0.33 | 0.71 | 0.19 | 0.71 | 1.1 | 100 | 1000 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1612 | -4 | 248 | 266 | blue | 5 class | 6 AWG | Polyamide | Yes | Yes | 0.47 | 0.35 | 0.38 | 0.47 | 0.24 | 0.47 | 0.94 | 100 | 800 | Yes | HL1 | HL2 | V2 | 486F |
| PKD1618 | -4 | 248 | 266 | blue | 5 class | 6 AWG | Polyamide | Yes | Yes | 0.39 | 0.35 | 0.38 | 0.71 | 0.24 | 0.71 | 1.1 | 100 | 800 | Yes | HL1 | HL2 | V2 | 486F |
| PKD35018 | -4 | 248 | 266 | red | 5 class | 2 AWG | Polyamide | Yes | Yes | 0.55 | 0.5 | 0.53 | 0.71 | 0.34 | 0.71 | 1.26 | 50 | 400 | Yes | HL1 | HL2 | V2 | |
| PKD25016 | -4 | 248 | 266 | yellow | 5 class | 4 AWG | Polyamide | Yes | Yes | 0.55 | 0.44 | 0.47 | 0.63 | 0.3 | 0.63 | 1.18 | 50 | 400 | Yes | HL1 | HL2 | V2 | 486F |
| PKD25022 | -4 | 248 | 266 | yellow | 5 class | 4 AWG | Polyamide | Yes | Yes | 0.55 | 0.44 | 0.47 | 0.87 | 0.3 | 0.87 | 1.42 | 50 | 400 | Yes | HL1 | HL2 | V2 | 486F |
| PKD25018 | -4 | 248 | 266 | yellow | 5 class | 4 AWG | Polyamide | Yes | Yes | 0.55 | 0.44 | 0.47 | 0.71 | 0.3 | 0.71 | 1.26 | 50 | 400 | Yes | HL1 | HL2 | V2 | |
| PKD35016 | -4 | 248 | 266 | red | 5 class | 2 AWG | Polyamide | Yes | Yes | 0.55 | 0.5 | 0.53 | 0.63 | 0.34 | 0.63 | 1.18 | 50 | 300 | Yes | HL1 | HL2 | V2 | 486F |
| PKD35025 | -4 | 248 | 266 | red | 5 class | 2 AWG | Polyamide | Yes | Yes | 0.55 | 0.5 | 0.53 | 0.98 | 0.34 | 0.98 | 1.54 | 50 | 200 | Yes | HL1 | HL2 | V2 | 486F |
| PKD50020 | -4 | 248 | 266 | blue | 5 class | 1 AWG | Polyamide | Yes | Yes | 0.63 | 0.59 | 0.65 | 0.79 | 0.43 | 0.79 | 1.42 | 50 | 200 | Yes | HL1 | HL2 | V2 | 486F |
| PKD50025 | -4 | 248 | 266 | blue | 5 class | 1 AWG | Polyamide | Yes | Yes | 0.59 | 0.59 | 0.65 | 0.98 | 0.43 | 0.98 | 1.57 | 50 | 150 | Yes | HL1 | HL2 | V2 | 486F |
| 100017 | 230 | blue | 14 AWG | Polypropylene | 0.28 | 0.17 | 0.19 | 0.43 | 0.1 | 0.39 | 0.67 | Yes | |||||||||||
| 100040 | 230 | yellow | 2/0 AWG | Polypropylene | 0.67 | 0.63 | 0.68 | 0.87 | 0.53 | 0.79 | 1.46 | 25 | 25 | Yes | |||||||||
| 100041 | 230 | yellow | 2/0 AWG | Polypropylene | 0.63 | 0.63 | 0.68 | 1.18 | 0.53 | 1.06 | 1.69 | 25 | 25 | Yes | |||||||||
| 100042 | 230 | red | 3/0 AWG | Polypropylene | 0.75 | 0.71 | 0.76 | 1.1 | 0.61 | 0.98 | 1.73 | 25 | 25 | Yes | |||||||||
| 100044 | 230 | blue | 4/0 AWG | Polypropylene | 0.83 | 0.79 | 0.84 | 1.18 | 0.69 | 1.06 | 1.89 | 25 | 25 | Yes | |||||||||
| 100046 | 230 | yellow | 300 kcmil | Polypropylene | 1.02 | 0.91 | 0.98 | 1.42 | 0.79 | 1.26 | 2.28 | 25 | 25 | Yes | |||||||||
PKD506
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
white
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
22 AWG - 20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.1
Ø3 [in]
0.12
Cable stripping length [in]
0.24
Ø1 [in]
0.05
P [in]
0.24
L [in]
0.47
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD508
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
white
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
22 AWG - 20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.1
Ø3 [in]
0.12
Cable stripping length [in]
0.31
Ø1 [in]
0.05
P [in]
0.31
L [in]
0.55
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD510
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
white
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
22 AWG - 20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.1
Ø3 [in]
0.12
Cable stripping length [in]
0.39
Ø1 [in]
0.05
P [in]
0.39
L [in]
0.63
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD7506
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.11
Ø3 [in]
0.13
Cable stripping length [in]
0.24
Ø1 [in]
0.06
P [in]
0.24
L [in]
0.47
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD7508
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.11
Ø3 [in]
0.13
Cable stripping length [in]
0.31
Ø1 [in]
0.06
P [in]
0.31
L [in]
0.55
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD7510
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.11
Ø3 [in]
0.13
Cable stripping length [in]
0.39
Ø1 [in]
0.06
P [in]
0.39
L [in]
0.63
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD7512
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
20 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.11
Ø3 [in]
0.13
Cable stripping length [in]
0.47
Ø1 [in]
0.06
P [in]
0.47
L [in]
0.71
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD106
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
18 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.12
Ø3 [in]
0.14
Cable stripping length [in]
0.24
Ø1 [in]
0.07
P [in]
0.24
L [in]
0.47
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD108
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
18 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.12
Ø3 [in]
0.14
Cable stripping length [in]
0.31
Ø1 [in]
0.07
P [in]
0.31
L [in]
0.55
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD110
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
18 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.12
Ø3 [in]
0.14
Cable stripping length [in]
0.39
Ø1 [in]
0.07
P [in]
0.39
L [in]
0.63
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
10000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD112
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
18 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.12
Ø3 [in]
0.14
Cable stripping length [in]
0.47
Ø1 [in]
0.07
P [in]
0.47
L [in]
0.71
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
8000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1508
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
black
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
16 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.14
Ø3 [in]
0.16
Cable stripping length [in]
0.31
Ø1 [in]
0.08
P [in]
0.31
L [in]
0.55
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1510
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
black
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
16 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.14
Ø3 [in]
0.16
Cable stripping length [in]
0.39
Ø1 [in]
0.08
P [in]
0.39
L [in]
0.63
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1512
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
black
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
16 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.14
Ø3 [in]
0.16
Cable stripping length [in]
0.47
Ø1 [in]
0.08
P [in]
0.47
L [in]
0.71
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1518
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
black
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
16 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.14
Ø3 [in]
0.16
Cable stripping length [in]
0.71
Ø1 [in]
0.08
P [in]
0.71
L [in]
0.94
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD2508
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
14 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.17
Ø3 [in]
0.19
Cable stripping length [in]
0.31
Ø1 [in]
0.1
P [in]
0.31
L [in]
0.55
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD2512
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
14 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.17
Ø3 [in]
0.19
Cable stripping length [in]
0.47
Ø1 [in]
0.1
P [in]
0.47
L [in]
0.71
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
4000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD2518
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
14 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.24
Ø2 [in]
0.17
Ø3 [in]
0.19
Cable stripping length [in]
0.71
Ø1 [in]
0.1
P [in]
0.71
L [in]
0.94
Unit in minimal packaging [pce]
500
Unit in standard packaging [pce]
5000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD410
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
12 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.28
Ø2 [in]
0.19
Ø3 [in]
0.21
Cable stripping length [in]
0.39
Ø1 [in]
0.13
P [in]
0.39
L [in]
0.67
Unit in minimal packaging [pce]
200
Unit in standard packaging [pce]
3000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD412
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
12 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.31
Ø2 [in]
0.19
Ø3 [in]
0.21
Cable stripping length [in]
0.47
Ø1 [in]
0.13
P [in]
0.47
L [in]
0.79
Unit in minimal packaging [pce]
200
Unit in standard packaging [pce]
3000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD418
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
grey
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
12 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.31
Ø2 [in]
0.19
Ø3 [in]
0.21
Cable stripping length [in]
0.71
Ø1 [in]
0.13
P [in]
0.71
L [in]
1.02
Unit in minimal packaging [pce]
200
Unit in standard packaging [pce]
3000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD612
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
yellow
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
10 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.31
Ø2 [in]
0.25
Ø3 [in]
0.27
Cable stripping length [in]
0.47
Ø1 [in]
0.15
P [in]
0.47
L [in]
0.79
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1500
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD618
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
yellow
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
10 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.31
Ø2 [in]
0.25
Ø3 [in]
0.27
Cable stripping length [in]
0.71
Ø1 [in]
0.15
P [in]
0.71
L [in]
1.02
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1500
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1012
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
8 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.39
Ø2 [in]
0.3
Ø3 [in]
0.33
Cable stripping length [in]
0.47
Ø1 [in]
0.19
P [in]
0.47
L [in]
0.87
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1018
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
8 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.39
Ø2 [in]
0.3
Ø3 [in]
0.33
Cable stripping length [in]
0.71
Ø1 [in]
0.19
P [in]
0.71
L [in]
1.1
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
1000
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1612
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
6 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.47
Ø2 [in]
0.35
Ø3 [in]
0.38
Cable stripping length [in]
0.47
Ø1 [in]
0.24
P [in]
0.47
L [in]
0.94
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
800
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD1618
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
6 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.39
Ø2 [in]
0.35
Ø3 [in]
0.38
Cable stripping length [in]
0.71
Ø1 [in]
0.24
P [in]
0.71
L [in]
1.1
Unit in minimal packaging [pce]
100
Unit in standard packaging [pce]
800
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD35018
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
2 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.55
Ø2 [in]
0.5
Ø3 [in]
0.53
Cable stripping length [in]
0.71
Ø1 [in]
0.34
P [in]
0.71
L [in]
1.26
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
400
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
–
PKD25016
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
yellow
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
4 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.55
Ø2 [in]
0.44
Ø3 [in]
0.47
Cable stripping length [in]
0.63
Ø1 [in]
0.3
P [in]
0.63
L [in]
1.18
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
400
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD25022
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
yellow
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
4 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.55
Ø2 [in]
0.44
Ø3 [in]
0.47
Cable stripping length [in]
0.87
Ø1 [in]
0.3
P [in]
0.87
L [in]
1.42
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
400
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD25018
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
yellow
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
4 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.55
Ø2 [in]
0.44
Ø3 [in]
0.47
Cable stripping length [in]
0.71
Ø1 [in]
0.3
P [in]
0.71
L [in]
1.26
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
400
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
–
PKD35016
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
2 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.55
Ø2 [in]
0.5
Ø3 [in]
0.53
Cable stripping length [in]
0.63
Ø1 [in]
0.34
P [in]
0.63
L [in]
1.18
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
300
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD35025
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
red
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
2 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.55
Ø2 [in]
0.5
Ø3 [in]
0.53
Cable stripping length [in]
0.98
Ø1 [in]
0.34
P [in]
0.98
L [in]
1.54
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
200
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD50020
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
1 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.63
Ø2 [in]
0.59
Ø3 [in]
0.65
Cable stripping length [in]
0.79
Ø1 [in]
0.43
P [in]
0.79
L [in]
1.42
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
200
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
PKD50025
Minimum operating temperature [°f]
-4
Maximum operating temperature [°f]
248
Threshold of operating temperature for short periods [°f]
266
Insulated cover color
blue
Compatible cable class
5 class
Range of cable cross section [awg/kcmil]
1 AWG
Insulated cover material
Polyamide
Annealing
Yes
Halogen free
Yes
C [in]
0.59
Ø2 [in]
0.59
Ø3 [in]
0.65
Cable stripping length [in]
0.98
Ø1 [in]
0.43
P [in]
0.98
L [in]
1.57
Unit in minimal packaging [pce]
50
Unit in standard packaging [pce]
150
ROHS compliant
Yes
EN 45545-2 certification (r22)
HL1
EN 45545-2 certification (r23)
HL2
Self-extinguishing fire class according to UL 94
V2
UL standard
486F
100017
Minimum operating temperature [°f]
–
Maximum operating temperature [°f]
230
Threshold of operating temperature for short periods [°f]
–
Insulated cover color
blue
Compatible cable class
–
Range of cable cross section [awg/kcmil]
14 AWG
Insulated cover material
Polypropylene
Annealing
–
Halogen free
–
C [in]
0.28
Ø2 [in]
0.17
Ø3 [in]
0.19
Cable stripping length [in]
0.43
Ø1 [in]
0.1
P [in]
0.39
L [in]
0.67
Unit in minimal packaging [pce]
–
Unit in standard packaging [pce]
–
ROHS compliant
Yes
EN 45545-2 certification (r22)
–
EN 45545-2 certification (r23)
–
Self-extinguishing fire class according to UL 94
–
UL standard
–
100040
Minimum operating temperature [°f]
–
Maximum operating temperature [°f]
230
Threshold of operating temperature for short periods [°f]
–
Insulated cover color
yellow
Compatible cable class
–
Range of cable cross section [awg/kcmil]
2/0 AWG
Insulated cover material
Polypropylene
Annealing
–
Halogen free
–
C [in]
0.67
Ø2 [in]
0.63
Ø3 [in]
0.68
Cable stripping length [in]
0.87
Ø1 [in]
0.53
P [in]
0.79
L [in]
1.46
Unit in minimal packaging [pce]
25
Unit in standard packaging [pce]
25
ROHS compliant
Yes
EN 45545-2 certification (r22)
–
EN 45545-2 certification (r23)
–
Self-extinguishing fire class according to UL 94
–
UL standard
–
100041
Minimum operating temperature [°f]
–
Maximum operating temperature [°f]
230
Threshold of operating temperature for short periods [°f]
–
Insulated cover color
yellow
Compatible cable class
–
Range of cable cross section [awg/kcmil]
2/0 AWG
Insulated cover material
Polypropylene
Annealing
–
Halogen free
–
C [in]
0.63
Ø2 [in]
0.63
Ø3 [in]
0.68
Cable stripping length [in]
1.18
Ø1 [in]
0.53
P [in]
1.06
L [in]
1.69
Unit in minimal packaging [pce]
25
Unit in standard packaging [pce]
25
ROHS compliant
Yes
EN 45545-2 certification (r22)
–
EN 45545-2 certification (r23)
–
Self-extinguishing fire class according to UL 94
–
UL standard
–
100042
Minimum operating temperature [°f]
–
Maximum operating temperature [°f]
230
Threshold of operating temperature for short periods [°f]
–
Insulated cover color
red
Compatible cable class
–
Range of cable cross section [awg/kcmil]
3/0 AWG
Insulated cover material
Polypropylene
Annealing
–
Halogen free
–
C [in]
0.75
Ø2 [in]
0.71
Ø3 [in]
0.76
Cable stripping length [in]
1.1
Ø1 [in]
0.61
P [in]
0.98
L [in]
1.73
Unit in minimal packaging [pce]
25
Unit in standard packaging [pce]
25
ROHS compliant
Yes
EN 45545-2 certification (r22)
–
EN 45545-2 certification (r23)
–
Self-extinguishing fire class according to UL 94
–
UL standard
–
100044
Minimum operating temperature [°f]
–
Maximum operating temperature [°f]
230
Threshold of operating temperature for short periods [°f]
–
Insulated cover color
blue
Compatible cable class
–
Range of cable cross section [awg/kcmil]
4/0 AWG
Insulated cover material
Polypropylene
Annealing
–
Halogen free
–
C [in]
0.83
Ø2 [in]
0.79
Ø3 [in]
0.84
Cable stripping length [in]
1.18
Ø1 [in]
0.69
P [in]
1.06
L [in]
1.89
Unit in minimal packaging [pce]
25
Unit in standard packaging [pce]
25
ROHS compliant
Yes
EN 45545-2 certification (r22)
–
EN 45545-2 certification (r23)
–
Self-extinguishing fire class according to UL 94
–
UL standard
–
100046
Minimum operating temperature [°f]
–
Maximum operating temperature [°f]
230
Threshold of operating temperature for short periods [°f]
–
Insulated cover color
yellow
Compatible cable class
–
Range of cable cross section [awg/kcmil]
300 kcmil
Insulated cover material
Polypropylene
Annealing
–
Halogen free
–
C [in]
1.02
Ø2 [in]
0.91
Ø3 [in]
0.98
Cable stripping length [in]
1.42
Ø1 [in]
0.79
P [in]
1.26
L [in]
2.28
Unit in minimal packaging [pce]
25
Unit in standard packaging [pce]
25
ROHS compliant
Yes
EN 45545-2 certification (r22)
–
EN 45545-2 certification (r23)
–
Self-extinguishing fire class according to UL 94
–
UL standard
–
Follow us
Subscribe to CEMBRE newsletter and stay tuned
Thank you, your request has been send successfully
You'll be contact soon by our commercial staff
Print label service
Fill in the form and follow the instructions to request the label print service
Thank you, your request has been send successfully
You'll be contact soon by our commercial staff